Cargando…
Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function
OBJECTIVES: To compare Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) with (99m)Tc-mebrofenin hepatobiliary scintigraphy (HBS) as quantitative liver function tests for the preoperative assessment of patients undergoing liver resection. METHODS: Patients undergoing liver sur...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682576/ https://www.ncbi.nlm.nih.gov/pubmed/30796575 http://dx.doi.org/10.1007/s00330-019-06029-7 |
_version_ | 1783441911579672576 |
---|---|
author | Rassam, F. Zhang, T. Cieslak, K. P. Lavini, C. Stoker, J. Bennink, R. J. van Gulik, T. M. van Vliet, L. J. Runge, J. H. Vos, F. M. |
author_facet | Rassam, F. Zhang, T. Cieslak, K. P. Lavini, C. Stoker, J. Bennink, R. J. van Gulik, T. M. van Vliet, L. J. Runge, J. H. Vos, F. M. |
author_sort | Rassam, F. |
collection | PubMed |
description | OBJECTIVES: To compare Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) with (99m)Tc-mebrofenin hepatobiliary scintigraphy (HBS) as quantitative liver function tests for the preoperative assessment of patients undergoing liver resection. METHODS: Patients undergoing liver surgery and preoperative assessment of future remnant liver (FRL) function using (99m)Tc-mebrofenin HBS were included. Patients underwent DHCE-MRI. Total liver uptake function was calculated for both modalities: mebrofenin uptake rate (MUR) and Ki respectively. The FRL was delineated with both SPECT-CT and MRI to calculate the functional share. Blood samples were taken to assess biochemical liver parameters. RESULTS: A total of 20 patients were included. The HBS-derived MUR and the DHCE-MRI-derived mean Ki correlated strongly for both total and FRL function (Pearson r = 0.70, p = 0.001 and r = 0.89, p < 0.001 respectively). There was a strong agreement between the functional share determined with both modalities (ICC = 0.944, 95% CI 0.863–0.978, n = 20). There was a significant negative correlation between liver aminotransferases and bilirubin for both MUR and Ki. CONCLUSIONS: Assessment of liver function with DHCE-MRI is comparable with that of (99m)Tc-mebrofenin HBS and has the potential to be combined with diagnostic MRI imaging. This can therefore provide a one-stop-shop modality for the preoperative assessment of patients undergoing liver surgery. KEY POINTS: • Quantitative assessment of liver function using hepatobiliary scintigraphy is performed in the preoperative assessment of patients undergoing liver surgery in order to prevent posthepatectomy liver failure. • Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) is an emerging method to quantify liver function and can serve as a potential alternative to hepatobiliary scintigraphy. • Assessment of liver function with dynamic gadoxetate-enhanced MRI is comparable with that of hepatobiliary scintigraphy and has the potential to be combined with diagnostic MRI imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06029-7) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6682576 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-66825762019-08-19 Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function Rassam, F. Zhang, T. Cieslak, K. P. Lavini, C. Stoker, J. Bennink, R. J. van Gulik, T. M. van Vliet, L. J. Runge, J. H. Vos, F. M. Eur Radiol Hepatobiliary-Pancreas OBJECTIVES: To compare Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) with (99m)Tc-mebrofenin hepatobiliary scintigraphy (HBS) as quantitative liver function tests for the preoperative assessment of patients undergoing liver resection. METHODS: Patients undergoing liver surgery and preoperative assessment of future remnant liver (FRL) function using (99m)Tc-mebrofenin HBS were included. Patients underwent DHCE-MRI. Total liver uptake function was calculated for both modalities: mebrofenin uptake rate (MUR) and Ki respectively. The FRL was delineated with both SPECT-CT and MRI to calculate the functional share. Blood samples were taken to assess biochemical liver parameters. RESULTS: A total of 20 patients were included. The HBS-derived MUR and the DHCE-MRI-derived mean Ki correlated strongly for both total and FRL function (Pearson r = 0.70, p = 0.001 and r = 0.89, p < 0.001 respectively). There was a strong agreement between the functional share determined with both modalities (ICC = 0.944, 95% CI 0.863–0.978, n = 20). There was a significant negative correlation between liver aminotransferases and bilirubin for both MUR and Ki. CONCLUSIONS: Assessment of liver function with DHCE-MRI is comparable with that of (99m)Tc-mebrofenin HBS and has the potential to be combined with diagnostic MRI imaging. This can therefore provide a one-stop-shop modality for the preoperative assessment of patients undergoing liver surgery. KEY POINTS: • Quantitative assessment of liver function using hepatobiliary scintigraphy is performed in the preoperative assessment of patients undergoing liver surgery in order to prevent posthepatectomy liver failure. • Gd-EOB-DTPA dynamic hepatocyte-specific contrast-enhanced MRI (DHCE-MRI) is an emerging method to quantify liver function and can serve as a potential alternative to hepatobiliary scintigraphy. • Assessment of liver function with dynamic gadoxetate-enhanced MRI is comparable with that of hepatobiliary scintigraphy and has the potential to be combined with diagnostic MRI imaging. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00330-019-06029-7) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2019-02-22 2019 /pmc/articles/PMC6682576/ /pubmed/30796575 http://dx.doi.org/10.1007/s00330-019-06029-7 Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Hepatobiliary-Pancreas Rassam, F. Zhang, T. Cieslak, K. P. Lavini, C. Stoker, J. Bennink, R. J. van Gulik, T. M. van Vliet, L. J. Runge, J. H. Vos, F. M. Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title | Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title_full | Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title_fullStr | Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title_full_unstemmed | Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title_short | Comparison between dynamic gadoxetate-enhanced MRI and (99m)Tc-mebrofenin hepatobiliary scintigraphy with SPECT for quantitative assessment of liver function |
title_sort | comparison between dynamic gadoxetate-enhanced mri and (99m)tc-mebrofenin hepatobiliary scintigraphy with spect for quantitative assessment of liver function |
topic | Hepatobiliary-Pancreas |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6682576/ https://www.ncbi.nlm.nih.gov/pubmed/30796575 http://dx.doi.org/10.1007/s00330-019-06029-7 |
work_keys_str_mv | AT rassamf comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT zhangt comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT cieslakkp comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT lavinic comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT stokerj comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT benninkrj comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT vanguliktm comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT vanvlietlj comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT rungejh comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction AT vosfm comparisonbetweendynamicgadoxetateenhancedmriand99mtcmebrofeninhepatobiliaryscintigraphywithspectforquantitativeassessmentofliverfunction |