Cargando…

Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads

BACKGROUND: Alloantibodies against human platelet antigens (HPAs) and human leukocyte antigen (HLA) are implicated in several immune-mediated platelet disorders. Detection of these antibodies is crucial in the diagnosis and management of these disorders. The aim of this study was to establish a nove...

Descripción completa

Detalles Bibliográficos
Autores principales: Tao, Sudan, Chen, Shu, Hong, Xiaozhen, He, Ji, Zhu, Faming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683390/
https://www.ncbi.nlm.nih.gov/pubmed/31382976
http://dx.doi.org/10.1186/s12967-019-2002-4
_version_ 1783442082138947584
author Tao, Sudan
Chen, Shu
Hong, Xiaozhen
He, Ji
Zhu, Faming
author_facet Tao, Sudan
Chen, Shu
Hong, Xiaozhen
He, Ji
Zhu, Faming
author_sort Tao, Sudan
collection PubMed
description BACKGROUND: Alloantibodies against human platelet antigens (HPAs) and human leukocyte antigen (HLA) are implicated in several immune-mediated platelet disorders. Detection of these antibodies is crucial in the diagnosis and management of these disorders. The aim of this study was to establish a novel method to simultaneously detect HPA-1, HPA-2, HPA-3, HPA-5 and HLA antibodies with Luminex microbeads technology. METHODS: Monoclonal antibodies specific for platelet glycoproteins and HLA class I molecules were separately coupled to the Luminex microbeads. We validated specificity of the Luminex platform using the following antibodies: anti-HPA-1a, anti-HPA-2b, anti-HPA-3a, anti-HPA-5a, and anti-HLA positive samples. Sensitivity was evaluated by a serial dilution (from neat to 1/1024) using the following antibodies: anti-HPA-1a, anti-HPA-3a standard sera, and anti-HPA-5a positive serum. Serum samples were collected from 36 neonatal alloimmune thrombocytopenia (NAIT) patients suspected of having HPA or HLA antibodies and 8 samples from ISBT platelet workshop were tested using the Luminex assay. RESULTS: The Luminex assay detected all antibodies tested from the known samples. The sensitivities of the Luminex assay detecting anti-HPA-1a, anti-HPA-3a, and anti-HPA-5a were 1:512, 1:64, and 1:128, respectively. The sensitivity of Luminex assay was higher than monoclonal antibody immobilization of platelet antigen method (MAIPA). No cross-reactivity was observed in the samples containing multi-platelet antibodies or mixture antibodies against HPA and HLA. The results of 44 samples with platelet disorders were consistent with those of the same samples processed with the MAIPA assay. CONCLUSION: Luminex microbeads coupled with monoclonal antibodies could be successfully used to detect HPA and HLA antibodies simultaneously, especially with high sensitivity in detecting HPA antibodies.
format Online
Article
Text
id pubmed-6683390
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66833902019-08-09 Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads Tao, Sudan Chen, Shu Hong, Xiaozhen He, Ji Zhu, Faming J Transl Med Research BACKGROUND: Alloantibodies against human platelet antigens (HPAs) and human leukocyte antigen (HLA) are implicated in several immune-mediated platelet disorders. Detection of these antibodies is crucial in the diagnosis and management of these disorders. The aim of this study was to establish a novel method to simultaneously detect HPA-1, HPA-2, HPA-3, HPA-5 and HLA antibodies with Luminex microbeads technology. METHODS: Monoclonal antibodies specific for platelet glycoproteins and HLA class I molecules were separately coupled to the Luminex microbeads. We validated specificity of the Luminex platform using the following antibodies: anti-HPA-1a, anti-HPA-2b, anti-HPA-3a, anti-HPA-5a, and anti-HLA positive samples. Sensitivity was evaluated by a serial dilution (from neat to 1/1024) using the following antibodies: anti-HPA-1a, anti-HPA-3a standard sera, and anti-HPA-5a positive serum. Serum samples were collected from 36 neonatal alloimmune thrombocytopenia (NAIT) patients suspected of having HPA or HLA antibodies and 8 samples from ISBT platelet workshop were tested using the Luminex assay. RESULTS: The Luminex assay detected all antibodies tested from the known samples. The sensitivities of the Luminex assay detecting anti-HPA-1a, anti-HPA-3a, and anti-HPA-5a were 1:512, 1:64, and 1:128, respectively. The sensitivity of Luminex assay was higher than monoclonal antibody immobilization of platelet antigen method (MAIPA). No cross-reactivity was observed in the samples containing multi-platelet antibodies or mixture antibodies against HPA and HLA. The results of 44 samples with platelet disorders were consistent with those of the same samples processed with the MAIPA assay. CONCLUSION: Luminex microbeads coupled with monoclonal antibodies could be successfully used to detect HPA and HLA antibodies simultaneously, especially with high sensitivity in detecting HPA antibodies. BioMed Central 2019-08-05 /pmc/articles/PMC6683390/ /pubmed/31382976 http://dx.doi.org/10.1186/s12967-019-2002-4 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Tao, Sudan
Chen, Shu
Hong, Xiaozhen
He, Ji
Zhu, Faming
Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title_full Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title_fullStr Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title_full_unstemmed Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title_short Novel method for simultaneously detecting HPA and HLA antibodies using Luminex microbeads
title_sort novel method for simultaneously detecting hpa and hla antibodies using luminex microbeads
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683390/
https://www.ncbi.nlm.nih.gov/pubmed/31382976
http://dx.doi.org/10.1186/s12967-019-2002-4
work_keys_str_mv AT taosudan novelmethodforsimultaneouslydetectinghpaandhlaantibodiesusingluminexmicrobeads
AT chenshu novelmethodforsimultaneouslydetectinghpaandhlaantibodiesusingluminexmicrobeads
AT hongxiaozhen novelmethodforsimultaneouslydetectinghpaandhlaantibodiesusingluminexmicrobeads
AT heji novelmethodforsimultaneouslydetectinghpaandhlaantibodiesusingluminexmicrobeads
AT zhufaming novelmethodforsimultaneouslydetectinghpaandhlaantibodiesusingluminexmicrobeads