Cargando…

Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation

BACKGROUND: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We per...

Descripción completa

Detalles Bibliográficos
Autores principales: Goudzwaard, Jeannette A, Disegna, Eleonora, de Ronde-Tillmans, Marjo JAG, Lenzen, Mattie J, de Jaegere, Peter PT, Mattace-Raso, Francesco US
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683966/
https://www.ncbi.nlm.nih.gov/pubmed/31447550
http://dx.doi.org/10.2147/CIA.S211328
_version_ 1783442194664783872
author Goudzwaard, Jeannette A
Disegna, Eleonora
de Ronde-Tillmans, Marjo JAG
Lenzen, Mattie J
de Jaegere, Peter PT
Mattace-Raso, Francesco US
author_facet Goudzwaard, Jeannette A
Disegna, Eleonora
de Ronde-Tillmans, Marjo JAG
Lenzen, Mattie J
de Jaegere, Peter PT
Mattace-Raso, Francesco US
author_sort Goudzwaard, Jeannette A
collection PubMed
description BACKGROUND: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We performed a study to investigate the possible short-term changes in aortic stiffness and other aortic functional properties after TAVI in older patients. METHODS: TAVI Care&Cure is an observational ongoing study including consecutive patients undergoing a TAVI procedure. Central and peripheral hemodynamic measurements were measured non invasively 1 day before (T-1) and 1 day after (T+1) TAVI using a validated oscillometric method using a brachial cuff (Mobil-O-Graph). RESULTS: 40 patients were included. Mean aortic valve area at baseline was 0.76±0.24 cm(2). Indices of severity of aortic valve stenosis improved significantly. Systolic blood pressure (SBP) dropped by 8.5%, from 130.3±22.9 mmHg to 119.5±15.8 mmHg (p=0.005). Diastolic blood pressure (DBP) dropped by 13.1% from 74.8±14.5 mmHg to 65.0±11.3 mmHg (p<0.001). The arterial pulse wave velocity (aPWV) decreased from 12.05±1.99 m/s to 11.6±1.56 m/s (p=0.006). Patients with high aPWV at baseline showed a significantly larger reduction in SBP in comparison to patients with low aPWV: – 20.3 mmHg (−14.1%) vs – 3.1 mmHg (−2.6%), respectively (p=0.033). The same trend was found for the DBP: −16.2 (−20.4%) vs −4.5 mmHg (−6.3%) for high vs low aPWV at baseline (p=0.037). CONCLUSION: We found short-term changes in blood pressure and aortic stiffness after TAVI. The amplitude of the changes was the largest in patients with elevated aortic stiffness at baseline.
format Online
Article
Text
id pubmed-6683966
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-66839662019-08-23 Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation Goudzwaard, Jeannette A Disegna, Eleonora de Ronde-Tillmans, Marjo JAG Lenzen, Mattie J de Jaegere, Peter PT Mattace-Raso, Francesco US Clin Interv Aging Original Research BACKGROUND: Both aortic valve stenosis and aortic stiffness are moderators of arterio ventricular coupling and independent predictors of cardiovascular morbidity and mortality. Studies on the effect of transcatheter aortic valve implantation (TAVI) on aortic functional properties are limited. We performed a study to investigate the possible short-term changes in aortic stiffness and other aortic functional properties after TAVI in older patients. METHODS: TAVI Care&Cure is an observational ongoing study including consecutive patients undergoing a TAVI procedure. Central and peripheral hemodynamic measurements were measured non invasively 1 day before (T-1) and 1 day after (T+1) TAVI using a validated oscillometric method using a brachial cuff (Mobil-O-Graph). RESULTS: 40 patients were included. Mean aortic valve area at baseline was 0.76±0.24 cm(2). Indices of severity of aortic valve stenosis improved significantly. Systolic blood pressure (SBP) dropped by 8.5%, from 130.3±22.9 mmHg to 119.5±15.8 mmHg (p=0.005). Diastolic blood pressure (DBP) dropped by 13.1% from 74.8±14.5 mmHg to 65.0±11.3 mmHg (p<0.001). The arterial pulse wave velocity (aPWV) decreased from 12.05±1.99 m/s to 11.6±1.56 m/s (p=0.006). Patients with high aPWV at baseline showed a significantly larger reduction in SBP in comparison to patients with low aPWV: – 20.3 mmHg (−14.1%) vs – 3.1 mmHg (−2.6%), respectively (p=0.033). The same trend was found for the DBP: −16.2 (−20.4%) vs −4.5 mmHg (−6.3%) for high vs low aPWV at baseline (p=0.037). CONCLUSION: We found short-term changes in blood pressure and aortic stiffness after TAVI. The amplitude of the changes was the largest in patients with elevated aortic stiffness at baseline. Dove 2019-08-02 /pmc/articles/PMC6683966/ /pubmed/31447550 http://dx.doi.org/10.2147/CIA.S211328 Text en © 2019 Goudzwaard et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
Goudzwaard, Jeannette A
Disegna, Eleonora
de Ronde-Tillmans, Marjo JAG
Lenzen, Mattie J
de Jaegere, Peter PT
Mattace-Raso, Francesco US
Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title_full Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title_fullStr Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title_full_unstemmed Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title_short Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
title_sort short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6683966/
https://www.ncbi.nlm.nih.gov/pubmed/31447550
http://dx.doi.org/10.2147/CIA.S211328
work_keys_str_mv AT goudzwaardjeannettea shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation
AT disegnaeleonora shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation
AT derondetillmansmarjojag shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation
AT lenzenmattiej shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation
AT dejaegerepeterpt shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation
AT mattacerasofrancescous shorttermchangesofbloodpressureandaorticstiffnessinolderpatientsaftertranscatheteraorticvalveimplantation