Cargando…

Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial

BACKGROUND: Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or a...

Descripción completa

Detalles Bibliográficos
Autores principales: Könneker, Sören, Krockenberger, Katja, Pieh, Claudia, von Falck, Christian, Brandewiede, Bernard, Vogt, Peter M., Kirschner, Martin H., Ziegler, Andreas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685162/
https://www.ncbi.nlm.nih.gov/pubmed/31387574
http://dx.doi.org/10.1186/s12891-019-2723-9
_version_ 1783442354454134784
author Könneker, Sören
Krockenberger, Katja
Pieh, Claudia
von Falck, Christian
Brandewiede, Bernard
Vogt, Peter M.
Kirschner, Martin H.
Ziegler, Andreas
author_facet Könneker, Sören
Krockenberger, Katja
Pieh, Claudia
von Falck, Christian
Brandewiede, Bernard
Vogt, Peter M.
Kirschner, Martin H.
Ziegler, Andreas
author_sort Könneker, Sören
collection PubMed
description BACKGROUND: Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures. METHODS: The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson’s score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life. DISCUSSION: This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation. TRIAL REGISTRATION: DRKS, DRKS00013368. Registered Dec 04, 2017. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-019-2723-9) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6685162
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66851622019-08-12 Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial Könneker, Sören Krockenberger, Katja Pieh, Claudia von Falck, Christian Brandewiede, Bernard Vogt, Peter M. Kirschner, Martin H. Ziegler, Andreas BMC Musculoskelet Disord Study Protocol BACKGROUND: Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures. METHODS: The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson’s score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life. DISCUSSION: This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation. TRIAL REGISTRATION: DRKS, DRKS00013368. Registered Dec 04, 2017. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12891-019-2723-9) contains supplementary material, which is available to authorized users. BioMed Central 2019-08-07 /pmc/articles/PMC6685162/ /pubmed/31387574 http://dx.doi.org/10.1186/s12891-019-2723-9 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Study Protocol
Könneker, Sören
Krockenberger, Katja
Pieh, Claudia
von Falck, Christian
Brandewiede, Bernard
Vogt, Peter M.
Kirschner, Martin H.
Ziegler, Andreas
Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title_full Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title_fullStr Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title_full_unstemmed Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title_short Comparison of SCAphoid fracture osteosynthesis by MAGnesium-based headless Herbert screws with titanium Herbert screws: protocol for the randomized controlled SCAMAG clinical trial
title_sort comparison of scaphoid fracture osteosynthesis by magnesium-based headless herbert screws with titanium herbert screws: protocol for the randomized controlled scamag clinical trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685162/
https://www.ncbi.nlm.nih.gov/pubmed/31387574
http://dx.doi.org/10.1186/s12891-019-2723-9
work_keys_str_mv AT konnekersoren comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT krockenbergerkatja comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT piehclaudia comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT vonfalckchristian comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT brandewiedebernard comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT vogtpeterm comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT kirschnermartinh comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial
AT zieglerandreas comparisonofscaphoidfractureosteosynthesisbymagnesiumbasedheadlessherbertscrewswithtitaniumherbertscrewsprotocolfortherandomizedcontrolledscamagclinicaltrial