Cargando…

Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy

BACKGROUND: Proteinuria is known to be associated with both kidney function deterioration and cardiovascular diseases. While proteinuria estimation from 24-h urine samples has traditionally been considered as the standard method for assessment of the degree of urinary protein excretion, sample colle...

Descripción completa

Detalles Bibliográficos
Autores principales: Kobayashi, Seiji, Amano, Hoichi, Terawaki, Hiroyuki, Ogura, Makoto, Kawaguchi, Yoshindo, Yokoo, Takashi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685245/
https://www.ncbi.nlm.nih.gov/pubmed/31387546
http://dx.doi.org/10.1186/s12882-019-1486-8
_version_ 1783442366468718592
author Kobayashi, Seiji
Amano, Hoichi
Terawaki, Hiroyuki
Ogura, Makoto
Kawaguchi, Yoshindo
Yokoo, Takashi
author_facet Kobayashi, Seiji
Amano, Hoichi
Terawaki, Hiroyuki
Ogura, Makoto
Kawaguchi, Yoshindo
Yokoo, Takashi
author_sort Kobayashi, Seiji
collection PubMed
description BACKGROUND: Proteinuria is known to be associated with both kidney function deterioration and cardiovascular diseases. While proteinuria estimation from 24-h urine samples has traditionally been considered as the standard method for assessment of the degree of urinary protein excretion, sample collection is associated with several technical problems such as inaccurate collection and the potential spread of drug-resistant pathogens. Therefore, the spot urine protein/creatinine ratio (PCR) assessment is currently recommended as an alternative. While the utility of PCR has been validated, studies on the association between spot urine PCR and 24-h proteinuria (24HP) in patients with chronic glomerular nephritis (CGN) and nephrotic syndrome (NS) are limited. This study aimed to evaluate whether an estimated result from a spot urine PCR could sufficiently approximate the daily urine protein excretion amount from a 24-h urine sample in patients with immunoglobulin A nephropathy (IgAN), minimal change disease (MCD), and membranous nephropathy– nephrotic syndrome (MN-NS). METHODS: The study participants included 161 patients with IgAN, MCD, or MGN-NS at the Jikei University Kashiwa Hospital and Kanagawa Prefecture Shiomidai Hospital. The correlation between spot urine PCR and a 24-h urine protein was investigated using linear regression analysis with Spearman’s correlation (r) coefficient and intraclass correlation coefficient (ICC). RESULTS: While high correlation coefficients (r = 0.86, P < 0.001) and substantial agreement (ICC: 0.806, P < 0.001) were observed in patients with IgAN, similar correlations were not observed in patients with MCD or MN-NS. In the patients with MCD, r was 0.53 (P < 0.001), which signified a slight correlation, and in the patients with MN-NS, r was 0.289 (P = 0.17), which was not statistically significant. CONCLUSIONS: This study revealed that spot urine PCR is a reliable estimate of 24HP value in patients with IgAN. In contrast, there is a considerable difference between the daily urine protein excretion amount based on a 24-h urine sample and that which is calculated from spot urine PCR in patients with NS.
format Online
Article
Text
id pubmed-6685245
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66852452019-08-12 Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy Kobayashi, Seiji Amano, Hoichi Terawaki, Hiroyuki Ogura, Makoto Kawaguchi, Yoshindo Yokoo, Takashi BMC Nephrol Research Article BACKGROUND: Proteinuria is known to be associated with both kidney function deterioration and cardiovascular diseases. While proteinuria estimation from 24-h urine samples has traditionally been considered as the standard method for assessment of the degree of urinary protein excretion, sample collection is associated with several technical problems such as inaccurate collection and the potential spread of drug-resistant pathogens. Therefore, the spot urine protein/creatinine ratio (PCR) assessment is currently recommended as an alternative. While the utility of PCR has been validated, studies on the association between spot urine PCR and 24-h proteinuria (24HP) in patients with chronic glomerular nephritis (CGN) and nephrotic syndrome (NS) are limited. This study aimed to evaluate whether an estimated result from a spot urine PCR could sufficiently approximate the daily urine protein excretion amount from a 24-h urine sample in patients with immunoglobulin A nephropathy (IgAN), minimal change disease (MCD), and membranous nephropathy– nephrotic syndrome (MN-NS). METHODS: The study participants included 161 patients with IgAN, MCD, or MGN-NS at the Jikei University Kashiwa Hospital and Kanagawa Prefecture Shiomidai Hospital. The correlation between spot urine PCR and a 24-h urine protein was investigated using linear regression analysis with Spearman’s correlation (r) coefficient and intraclass correlation coefficient (ICC). RESULTS: While high correlation coefficients (r = 0.86, P < 0.001) and substantial agreement (ICC: 0.806, P < 0.001) were observed in patients with IgAN, similar correlations were not observed in patients with MCD or MN-NS. In the patients with MCD, r was 0.53 (P < 0.001), which signified a slight correlation, and in the patients with MN-NS, r was 0.289 (P = 0.17), which was not statistically significant. CONCLUSIONS: This study revealed that spot urine PCR is a reliable estimate of 24HP value in patients with IgAN. In contrast, there is a considerable difference between the daily urine protein excretion amount based on a 24-h urine sample and that which is calculated from spot urine PCR in patients with NS. BioMed Central 2019-08-06 /pmc/articles/PMC6685245/ /pubmed/31387546 http://dx.doi.org/10.1186/s12882-019-1486-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Kobayashi, Seiji
Amano, Hoichi
Terawaki, Hiroyuki
Ogura, Makoto
Kawaguchi, Yoshindo
Yokoo, Takashi
Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title_full Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title_fullStr Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title_full_unstemmed Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title_short Spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin A nephropathy, but not membranous nephropathy
title_sort spot urine protein/creatinine ratio as a reliable estimate of 24-hour proteinuria in patients with immunoglobulin a nephropathy, but not membranous nephropathy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685245/
https://www.ncbi.nlm.nih.gov/pubmed/31387546
http://dx.doi.org/10.1186/s12882-019-1486-8
work_keys_str_mv AT kobayashiseiji spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy
AT amanohoichi spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy
AT terawakihiroyuki spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy
AT oguramakoto spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy
AT kawaguchiyoshindo spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy
AT yokootakashi spoturineproteincreatinineratioasareliableestimateof24hourproteinuriainpatientswithimmunoglobulinanephropathybutnotmembranousnephropathy