Cargando…

Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length

PURPOSE: To evaluate the relationships between refractive error, axial length (AL), and retinal vascular oxygen saturation in an adult population. METHODS: This was a hospital-based, prospective observational study. The left eyes of phakic adult subjects without media opacity were analyzed. Subjecti...

Descripción completa

Detalles Bibliográficos
Autores principales: Lim, Laurence Shen, Lim, Xian Hui, Tan, Licia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685695/
https://www.ncbi.nlm.nih.gov/pubmed/31403000
http://dx.doi.org/10.1167/tvst.8.4.22
_version_ 1783442444357992448
author Lim, Laurence Shen
Lim, Xian Hui
Tan, Licia
author_facet Lim, Laurence Shen
Lim, Xian Hui
Tan, Licia
author_sort Lim, Laurence Shen
collection PubMed
description PURPOSE: To evaluate the relationships between refractive error, axial length (AL), and retinal vascular oxygen saturation in an adult population. METHODS: This was a hospital-based, prospective observational study. The left eyes of phakic adult subjects without media opacity were analyzed. Subjective undilated manifest refraction was performed, and refractive errors were defined as myopia (spherical equivalent [SE], <−1 D), emmetropia (SE between −1 D and +1 D) and hyperopia (SE >+1 D). Retinal oximetry was performed using the Oxymap system (Oxymap Inc., Reykjavik, Iceland). Multivariate linear regression models were constructed to assess the relationship between retinal vascular oxygen saturation, SE, and AL obtained with optical biometry, with adjustments for age, sex, race, blood pressure, hyperlipidemia, and diabetes mellitus. RESULTS: There were 85 subjects, with mean age of 66.1 ± 11.3 years. The majority were female (60%) and Chinese (84%). A total of 60% were myopic, 28% emmetropic, and 12% hyperopic. Mean SE was −5.29 ± 6.51 D and mean AL was 25.30 ± 2.99 mm. In multivariate analyses, more myopic SE and longer AL were associated with lower retinal arteriolar oxygen saturation (regression coefficient B = 0.61 [95% confidence interval, 0.28, 0.95], P = 0.001; and B = −1.13 [95% confidence interval, −1.71, −0.56], P < 0.001, respectively). Subjects with myopic SE and AL also had lower retinal arteriolar oxygen saturation than emmetropes and hyperopes (P = 0.03 and P = 0.02, respectively). CONCLUSIONS: Eyes with more myopic SE and longer AL have lower retinal arteriolar oxygen saturation. TRANSLATIONAL RELEVANCE: This study provides direct evidence of a link between retinal oxygenation and hypoxia and myopia by using a novel device that quantifies retinal vascular oxygenation in vivo.
format Online
Article
Text
id pubmed-6685695
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-66856952019-08-09 Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length Lim, Laurence Shen Lim, Xian Hui Tan, Licia Transl Vis Sci Technol Articles PURPOSE: To evaluate the relationships between refractive error, axial length (AL), and retinal vascular oxygen saturation in an adult population. METHODS: This was a hospital-based, prospective observational study. The left eyes of phakic adult subjects without media opacity were analyzed. Subjective undilated manifest refraction was performed, and refractive errors were defined as myopia (spherical equivalent [SE], <−1 D), emmetropia (SE between −1 D and +1 D) and hyperopia (SE >+1 D). Retinal oximetry was performed using the Oxymap system (Oxymap Inc., Reykjavik, Iceland). Multivariate linear regression models were constructed to assess the relationship between retinal vascular oxygen saturation, SE, and AL obtained with optical biometry, with adjustments for age, sex, race, blood pressure, hyperlipidemia, and diabetes mellitus. RESULTS: There were 85 subjects, with mean age of 66.1 ± 11.3 years. The majority were female (60%) and Chinese (84%). A total of 60% were myopic, 28% emmetropic, and 12% hyperopic. Mean SE was −5.29 ± 6.51 D and mean AL was 25.30 ± 2.99 mm. In multivariate analyses, more myopic SE and longer AL were associated with lower retinal arteriolar oxygen saturation (regression coefficient B = 0.61 [95% confidence interval, 0.28, 0.95], P = 0.001; and B = −1.13 [95% confidence interval, −1.71, −0.56], P < 0.001, respectively). Subjects with myopic SE and AL also had lower retinal arteriolar oxygen saturation than emmetropes and hyperopes (P = 0.03 and P = 0.02, respectively). CONCLUSIONS: Eyes with more myopic SE and longer AL have lower retinal arteriolar oxygen saturation. TRANSLATIONAL RELEVANCE: This study provides direct evidence of a link between retinal oxygenation and hypoxia and myopia by using a novel device that quantifies retinal vascular oxygenation in vivo. The Association for Research in Vision and Ophthalmology 2019-08-07 /pmc/articles/PMC6685695/ /pubmed/31403000 http://dx.doi.org/10.1167/tvst.8.4.22 Text en Copyright 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Articles
Lim, Laurence Shen
Lim, Xian Hui
Tan, Licia
Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title_full Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title_fullStr Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title_full_unstemmed Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title_short Retinal Vascular Oxygen Saturation and Its Variation With Refractive Error and Axial Length
title_sort retinal vascular oxygen saturation and its variation with refractive error and axial length
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6685695/
https://www.ncbi.nlm.nih.gov/pubmed/31403000
http://dx.doi.org/10.1167/tvst.8.4.22
work_keys_str_mv AT limlaurenceshen retinalvascularoxygensaturationanditsvariationwithrefractiveerrorandaxiallength
AT limxianhui retinalvascularoxygensaturationanditsvariationwithrefractiveerrorandaxiallength
AT tanlicia retinalvascularoxygensaturationanditsvariationwithrefractiveerrorandaxiallength