Cargando…

mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease

BACKGROUND: Cardiovascular magnetic resonance (CMR) angiography (CMRA) is an important non-invasive imaging tool for congenital heart disease (CHD) and aortopathy patients. The conventional 3D balanced steady-state free precession (bSSFP) sequence is often confounded by imaging artifacts. We sought...

Descripción completa

Detalles Bibliográficos
Autores principales: Kourtidou, Soultana, Jones, Marty R., Moore, Ryan A., Tretter, Justin T., Ollberding, Nicholas J., Crotty, Eric J., Rattan, Mantosh S., Fleck, Robert J., Taylor, Michael D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6686451/
https://www.ncbi.nlm.nih.gov/pubmed/31391061
http://dx.doi.org/10.1186/s12968-019-0554-3
_version_ 1783442568928821248
author Kourtidou, Soultana
Jones, Marty R.
Moore, Ryan A.
Tretter, Justin T.
Ollberding, Nicholas J.
Crotty, Eric J.
Rattan, Mantosh S.
Fleck, Robert J.
Taylor, Michael D.
author_facet Kourtidou, Soultana
Jones, Marty R.
Moore, Ryan A.
Tretter, Justin T.
Ollberding, Nicholas J.
Crotty, Eric J.
Rattan, Mantosh S.
Fleck, Robert J.
Taylor, Michael D.
author_sort Kourtidou, Soultana
collection PubMed
description BACKGROUND: Cardiovascular magnetic resonance (CMR) angiography (CMRA) is an important non-invasive imaging tool for congenital heart disease (CHD) and aortopathy patients. The conventional 3D balanced steady-state free precession (bSSFP) sequence is often confounded by imaging artifacts. We sought to compare the respiratory navigated and electrocardiogram (ECG) gated modified Dixon (mDixon) CMRA sequence to conventional non-gated dynamic multi-phase contrast enhanced CMRA (CE-CMRA) and bSSFP across a variety of diagnoses. METHODS: We included 24 patients with CHD or aortopathy with CMR performed between September 2017 to December 2017. Each patient had undergone CE-CMRA, followed by a bSSFP and mDixon angiogram. Patients with CMR-incompatible implants or contraindications to contrast were excluded. The studies were rated according to image quality at a scale from 1 (poor) to 4 (excellent) based on diagnostic adequacy, artifact burden, vascular border delineation, myocardium-blood pool contrast, and visualization of pulmonary and systemic veins and coronaries. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and quantitative vascular measurements were compared between the two gated sequences. Bland-Altman plots were generated to compare paired measures. RESULTS: All scans were diagnostically adequate. Mean (SD) quality scores were 3.4 (0.7) for the mDixon, 3.2 (0.5) for the bSSFP and 3.4 (0.5) for the CE-CMRA. Qualitatively, the intracardiac anatomy and myocardium-blood pool definition were better in the bSSFP; however, mDixon images showed enhanced vessel wall sharpness with less blurring surrounding the anatomical borders distally. Coronary origins were identified in all cases. Pulmonary veins were visualized in 92% of mDixon sequences, 75% of bSSFP and 96% of CE-CMRA. Similarly, neck veins were identified in 92, 83 and 96% respectively. Artifacts prevented vascular measurement in 6/192 (3%) and 4/192 (2%) of total vascular measurements for the mDixon and bSSFP, respectively. However, the size of signal void and field distortion were significantly worse in the latter, particularly for flow and metal induced artifacts. CONCLUSION: In patients with congenital heart disease, ECG gated mDixon angiography yields high fidelity vascular images including better delineation of head and neck vasculature and pulmonary veins and fewer artifacts than the comparable bSSFP sequence. It should be considered as the preferred strategy for successful CHD imaging in patients with valve stenosis, vascular stents, or metallic implants. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0554-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6686451
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66864512019-08-12 mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease Kourtidou, Soultana Jones, Marty R. Moore, Ryan A. Tretter, Justin T. Ollberding, Nicholas J. Crotty, Eric J. Rattan, Mantosh S. Fleck, Robert J. Taylor, Michael D. J Cardiovasc Magn Reson Research BACKGROUND: Cardiovascular magnetic resonance (CMR) angiography (CMRA) is an important non-invasive imaging tool for congenital heart disease (CHD) and aortopathy patients. The conventional 3D balanced steady-state free precession (bSSFP) sequence is often confounded by imaging artifacts. We sought to compare the respiratory navigated and electrocardiogram (ECG) gated modified Dixon (mDixon) CMRA sequence to conventional non-gated dynamic multi-phase contrast enhanced CMRA (CE-CMRA) and bSSFP across a variety of diagnoses. METHODS: We included 24 patients with CHD or aortopathy with CMR performed between September 2017 to December 2017. Each patient had undergone CE-CMRA, followed by a bSSFP and mDixon angiogram. Patients with CMR-incompatible implants or contraindications to contrast were excluded. The studies were rated according to image quality at a scale from 1 (poor) to 4 (excellent) based on diagnostic adequacy, artifact burden, vascular border delineation, myocardium-blood pool contrast, and visualization of pulmonary and systemic veins and coronaries. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR) and quantitative vascular measurements were compared between the two gated sequences. Bland-Altman plots were generated to compare paired measures. RESULTS: All scans were diagnostically adequate. Mean (SD) quality scores were 3.4 (0.7) for the mDixon, 3.2 (0.5) for the bSSFP and 3.4 (0.5) for the CE-CMRA. Qualitatively, the intracardiac anatomy and myocardium-blood pool definition were better in the bSSFP; however, mDixon images showed enhanced vessel wall sharpness with less blurring surrounding the anatomical borders distally. Coronary origins were identified in all cases. Pulmonary veins were visualized in 92% of mDixon sequences, 75% of bSSFP and 96% of CE-CMRA. Similarly, neck veins were identified in 92, 83 and 96% respectively. Artifacts prevented vascular measurement in 6/192 (3%) and 4/192 (2%) of total vascular measurements for the mDixon and bSSFP, respectively. However, the size of signal void and field distortion were significantly worse in the latter, particularly for flow and metal induced artifacts. CONCLUSION: In patients with congenital heart disease, ECG gated mDixon angiography yields high fidelity vascular images including better delineation of head and neck vasculature and pulmonary veins and fewer artifacts than the comparable bSSFP sequence. It should be considered as the preferred strategy for successful CHD imaging in patients with valve stenosis, vascular stents, or metallic implants. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12968-019-0554-3) contains supplementary material, which is available to authorized users. BioMed Central 2019-08-08 /pmc/articles/PMC6686451/ /pubmed/31391061 http://dx.doi.org/10.1186/s12968-019-0554-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Kourtidou, Soultana
Jones, Marty R.
Moore, Ryan A.
Tretter, Justin T.
Ollberding, Nicholas J.
Crotty, Eric J.
Rattan, Mantosh S.
Fleck, Robert J.
Taylor, Michael D.
mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title_full mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title_fullStr mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title_full_unstemmed mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title_short mDixon ECG-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
title_sort mdixon ecg-gated 3-dimensional cardiovascular magnetic resonance angiography in patients with congenital cardiovascular disease
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6686451/
https://www.ncbi.nlm.nih.gov/pubmed/31391061
http://dx.doi.org/10.1186/s12968-019-0554-3
work_keys_str_mv AT kourtidousoultana mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT jonesmartyr mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT mooreryana mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT tretterjustint mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT ollberdingnicholasj mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT crottyericj mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT rattanmantoshs mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT fleckrobertj mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease
AT taylormichaeld mdixonecggated3dimensionalcardiovascularmagneticresonanceangiographyinpatientswithcongenitalcardiovasculardisease