Cargando…

Advanced Imaging Modalities to Monitor for Cardiotoxicity

Early detection and treatment of cardiotoxicity from cancer therapies is key to preventing a rise in adverse cardiovascular outcomes in cancer patients. Over-diagnosis of cardiotoxicity in this context is however equally hazardous, leading to patients receiving suboptimal cancer treatment, thereby i...

Descripción completa

Detalles Bibliográficos
Autores principales: Seraphim, Andreas, Westwood, Mark, Bhuva, Anish N., Crake, Tom, Moon, James C., Menezes, Leon J., Lloyd, Guy, Ghosh, Arjun K., Slater, Sarah, Oakervee, Heather, Manisty, Charlotte H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687672/
https://www.ncbi.nlm.nih.gov/pubmed/31396720
http://dx.doi.org/10.1007/s11864-019-0672-z
_version_ 1783442753144750080
author Seraphim, Andreas
Westwood, Mark
Bhuva, Anish N.
Crake, Tom
Moon, James C.
Menezes, Leon J.
Lloyd, Guy
Ghosh, Arjun K.
Slater, Sarah
Oakervee, Heather
Manisty, Charlotte H.
author_facet Seraphim, Andreas
Westwood, Mark
Bhuva, Anish N.
Crake, Tom
Moon, James C.
Menezes, Leon J.
Lloyd, Guy
Ghosh, Arjun K.
Slater, Sarah
Oakervee, Heather
Manisty, Charlotte H.
author_sort Seraphim, Andreas
collection PubMed
description Early detection and treatment of cardiotoxicity from cancer therapies is key to preventing a rise in adverse cardiovascular outcomes in cancer patients. Over-diagnosis of cardiotoxicity in this context is however equally hazardous, leading to patients receiving suboptimal cancer treatment, thereby impacting cancer outcomes. Accurate screening therefore depends on the widespread availability of sensitive and reproducible biomarkers of cardiotoxicity, which can clearly discriminate early disease. Blood biomarkers are limited in cardiovascular disease and clinicians generally still use generic screening with ejection fraction, based on historical local expertise and resources. Recently, however, there has been growing recognition that simple measurement of left ventricular ejection fraction using 2D echocardiography may not be optimal for screening: diagnostic accuracy, reproducibility and feasibility are limited. Modern cancer therapies affect many myocardial pathways: inflammatory, fibrotic, metabolic, vascular and myocyte function, meaning that multiple biomarkers may be needed to track myocardial cardiotoxicity. Advanced imaging modalities including cardiovascular magnetic resonance (CMR), computed tomography (CT) and positron emission tomography (PET) add improved sensitivity and insights into the underlying pathophysiology, as well as the ability to screen for other cardiotoxicities including coronary artery, valve and pericardial diseases resulting from cancer treatment. Delivering screening for cardiotoxicity using advanced imaging modalities will however require a significant change in current clinical pathways, with incorporation of machine learning algorithms into imaging analysis fundamental to improving efficiency and precision. In the future, we should aspire to personalized rather than generic screening, based on a patient’s individual risk factors and the pathophysiological mechanisms of the cancer treatment they are receiving. We should aspire that progress in cardiooncology is able to track progress in oncology, and to ensure that the current ‘one size fits all’ approach to screening be obsolete in the very near future.
format Online
Article
Text
id pubmed-6687672
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-66876722019-08-23 Advanced Imaging Modalities to Monitor for Cardiotoxicity Seraphim, Andreas Westwood, Mark Bhuva, Anish N. Crake, Tom Moon, James C. Menezes, Leon J. Lloyd, Guy Ghosh, Arjun K. Slater, Sarah Oakervee, Heather Manisty, Charlotte H. Curr Treat Options Oncol Cardio-oncology (MG Fradley, Section Editor) Early detection and treatment of cardiotoxicity from cancer therapies is key to preventing a rise in adverse cardiovascular outcomes in cancer patients. Over-diagnosis of cardiotoxicity in this context is however equally hazardous, leading to patients receiving suboptimal cancer treatment, thereby impacting cancer outcomes. Accurate screening therefore depends on the widespread availability of sensitive and reproducible biomarkers of cardiotoxicity, which can clearly discriminate early disease. Blood biomarkers are limited in cardiovascular disease and clinicians generally still use generic screening with ejection fraction, based on historical local expertise and resources. Recently, however, there has been growing recognition that simple measurement of left ventricular ejection fraction using 2D echocardiography may not be optimal for screening: diagnostic accuracy, reproducibility and feasibility are limited. Modern cancer therapies affect many myocardial pathways: inflammatory, fibrotic, metabolic, vascular and myocyte function, meaning that multiple biomarkers may be needed to track myocardial cardiotoxicity. Advanced imaging modalities including cardiovascular magnetic resonance (CMR), computed tomography (CT) and positron emission tomography (PET) add improved sensitivity and insights into the underlying pathophysiology, as well as the ability to screen for other cardiotoxicities including coronary artery, valve and pericardial diseases resulting from cancer treatment. Delivering screening for cardiotoxicity using advanced imaging modalities will however require a significant change in current clinical pathways, with incorporation of machine learning algorithms into imaging analysis fundamental to improving efficiency and precision. In the future, we should aspire to personalized rather than generic screening, based on a patient’s individual risk factors and the pathophysiological mechanisms of the cancer treatment they are receiving. We should aspire that progress in cardiooncology is able to track progress in oncology, and to ensure that the current ‘one size fits all’ approach to screening be obsolete in the very near future. Springer US 2019-08-08 2019 /pmc/articles/PMC6687672/ /pubmed/31396720 http://dx.doi.org/10.1007/s11864-019-0672-z Text en © The Author(s) 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Cardio-oncology (MG Fradley, Section Editor)
Seraphim, Andreas
Westwood, Mark
Bhuva, Anish N.
Crake, Tom
Moon, James C.
Menezes, Leon J.
Lloyd, Guy
Ghosh, Arjun K.
Slater, Sarah
Oakervee, Heather
Manisty, Charlotte H.
Advanced Imaging Modalities to Monitor for Cardiotoxicity
title Advanced Imaging Modalities to Monitor for Cardiotoxicity
title_full Advanced Imaging Modalities to Monitor for Cardiotoxicity
title_fullStr Advanced Imaging Modalities to Monitor for Cardiotoxicity
title_full_unstemmed Advanced Imaging Modalities to Monitor for Cardiotoxicity
title_short Advanced Imaging Modalities to Monitor for Cardiotoxicity
title_sort advanced imaging modalities to monitor for cardiotoxicity
topic Cardio-oncology (MG Fradley, Section Editor)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6687672/
https://www.ncbi.nlm.nih.gov/pubmed/31396720
http://dx.doi.org/10.1007/s11864-019-0672-z
work_keys_str_mv AT seraphimandreas advancedimagingmodalitiestomonitorforcardiotoxicity
AT westwoodmark advancedimagingmodalitiestomonitorforcardiotoxicity
AT bhuvaanishn advancedimagingmodalitiestomonitorforcardiotoxicity
AT craketom advancedimagingmodalitiestomonitorforcardiotoxicity
AT moonjamesc advancedimagingmodalitiestomonitorforcardiotoxicity
AT menezesleonj advancedimagingmodalitiestomonitorforcardiotoxicity
AT lloydguy advancedimagingmodalitiestomonitorforcardiotoxicity
AT ghosharjunk advancedimagingmodalitiestomonitorforcardiotoxicity
AT slatersarah advancedimagingmodalitiestomonitorforcardiotoxicity
AT oakerveeheather advancedimagingmodalitiestomonitorforcardiotoxicity
AT manistycharlotteh advancedimagingmodalitiestomonitorforcardiotoxicity