Cargando…

Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department

OBJECTIVES: Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI. DESIGN: Five commonly requested MRI sequences...

Descripción completa

Detalles Bibliográficos
Autores principales: Izatt, Maree T, Lees, Deborah, Mills, Susan, Grant, Caroline A, Little, J Paige
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6688688/
https://www.ncbi.nlm.nih.gov/pubmed/31375607
http://dx.doi.org/10.1136/bmjopen-2018-027020
_version_ 1783442927663448064
author Izatt, Maree T
Lees, Deborah
Mills, Susan
Grant, Caroline A
Little, J Paige
author_facet Izatt, Maree T
Lees, Deborah
Mills, Susan
Grant, Caroline A
Little, J Paige
author_sort Izatt, Maree T
collection PubMed
description OBJECTIVES: Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI. DESIGN: Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker). SETTING: Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group. INTERVENTIONS: 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined. MAIN OUTCOME MEASURES: Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale. RESULTS: The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine ‘play doh’ and a soft ‘Jelly baby’ sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence. CONCLUSIONS: Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed.
format Online
Article
Text
id pubmed-6688688
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-66886882019-08-16 Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department Izatt, Maree T Lees, Deborah Mills, Susan Grant, Caroline A Little, J Paige BMJ Open Qualitative Research OBJECTIVES: Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI. DESIGN: Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker). SETTING: Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group. INTERVENTIONS: 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined. MAIN OUTCOME MEASURES: Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale. RESULTS: The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine ‘play doh’ and a soft ‘Jelly baby’ sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence. CONCLUSIONS: Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed. BMJ Publishing Group 2019-08-01 /pmc/articles/PMC6688688/ /pubmed/31375607 http://dx.doi.org/10.1136/bmjopen-2018-027020 Text en © Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. Published by BMJ. This is an open access article distributed in accordance with the Creative Commons Attribution 4.0 Unported (CC BY 4.0) license, which permits others to copy, redistribute, remix, transform and build upon this work for any purpose, provided the original work is properly cited, a link to the licence is given, and indication of whether changes were made. See: https://creativecommons.org/licenses/by/4.0/.
spellingShingle Qualitative Research
Izatt, Maree T
Lees, Deborah
Mills, Susan
Grant, Caroline A
Little, J Paige
Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_full Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_fullStr Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_full_unstemmed Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_short Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department
title_sort determining a reliably visible and inexpensive surface fiducial marker for use in mri: a research study in a busy australian radiology department
topic Qualitative Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6688688/
https://www.ncbi.nlm.nih.gov/pubmed/31375607
http://dx.doi.org/10.1136/bmjopen-2018-027020
work_keys_str_mv AT izattmareet determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT leesdeborah determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT millssusan determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT grantcarolinea determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment
AT littlejpaige determiningareliablyvisibleandinexpensivesurfacefiducialmarkerforuseinmriaresearchstudyinabusyaustralianradiologydepartment