Respiratory follow-up pre- and post-engineering controls or cessation of added diacetyl at four microwave popcorn facilities

In a 7-year study at 4 microwave popcorn facilities, mixing room employees exposed to diacetyl prior to the introduction of respirators showed significant loss of lung function but did not continue to decline longitudinally faster than other job categories http://bit.ly/2xwWRiw

Detalles Bibliográficos
Autores principales: Lockey, James E., Hilbert, Timothy J., LeMasters, Grace, Dunning, Kari K., McKay, Roy T., Levin, Linda S., Rice, Carol H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: European Respiratory Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6689669/
https://www.ncbi.nlm.nih.gov/pubmed/31423448
http://dx.doi.org/10.1183/23120541.00042-2019
Descripción
Sumario:In a 7-year study at 4 microwave popcorn facilities, mixing room employees exposed to diacetyl prior to the introduction of respirators showed significant loss of lung function but did not continue to decline longitudinally faster than other job categories http://bit.ly/2xwWRiw