Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment
PURPOSE: Sensitively assessing bronchial reversibility by spirometry is difficult in patients with serious airflow limitation and the elderly. Some patients cannot exhale for ≥6 s to achieve FVC testing criteria. The aim of this study was to assess if FEV(3) could be a more sensitive and an acceptab...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6689797/ https://www.ncbi.nlm.nih.gov/pubmed/31496679 http://dx.doi.org/10.2147/COPD.S197552 |
_version_ | 1783443087827140608 |
---|---|
author | Pan, Mingming Zhang, Hongsheng Sun, Tieying |
author_facet | Pan, Mingming Zhang, Hongsheng Sun, Tieying |
author_sort | Pan, Mingming |
collection | PubMed |
description | PURPOSE: Sensitively assessing bronchial reversibility by spirometry is difficult in patients with serious airflow limitation and the elderly. Some patients cannot exhale for ≥6 s to achieve FVC testing criteria. The aim of this study was to assess if FEV(3) could be a more sensitive and an acceptable surrogate for evaluating bronchial reversibility in such patients. PATIENTS AND METHODS: Subjects who had undergone pulmonary function examination in Beijing hospital from July 2003 to April 2015 were included in the study. Patients with FEV(1)<50% of the predicted value were classified as the severely lung function–impaired group. Correlation between the severity of lung function impairment and changes in FEV(1), FEV(3) and FVC in response to a bronchodilator was estimated. RESULTS: A total of 7745 tests on elderly subjects with a median age of 71 years were reviewed. The severely lung function–impaired group of 1728 accounted for 22.3% of the total number of subjects. There were significantly more patients in the severely lung function–impaired group who exhibited positive response in FEV(3) or FVC and negative response in FEV(1) after bronchodilator test (FEV(1) negative response but FVC positive response, χ2=626.97, P<0.001; FEV(1) negative response but FEV(3) positive response, χ2=372.83, P<0.001). With the progressive increase in lung function impairment, ΔFEV(1) increased and then declined, while ΔFVC and ΔFEV(3) increased progressively. Changes in FEV(3) or FVC significantly exceeded the change in FEV(1) in the severely lung function–impaired groups (P<0.001). CONCLUSION: In elderly subjects, especially those with severe lung function impairment, FEV(3) combined with FVC is a more effective and sensitive primary clinical outcome measure to detect bronchial reversibility. In subjects who cannot complete ≥6 s forced expiration and whose FVC is unreliable, FEV(3) combined with FEV(1) might be clinically more valuable in detecting bronchial reversibility. |
format | Online Article Text |
id | pubmed-6689797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Dove |
record_format | MEDLINE/PubMed |
spelling | pubmed-66897972019-09-06 Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment Pan, Mingming Zhang, Hongsheng Sun, Tieying Int J Chron Obstruct Pulmon Dis Original Research PURPOSE: Sensitively assessing bronchial reversibility by spirometry is difficult in patients with serious airflow limitation and the elderly. Some patients cannot exhale for ≥6 s to achieve FVC testing criteria. The aim of this study was to assess if FEV(3) could be a more sensitive and an acceptable surrogate for evaluating bronchial reversibility in such patients. PATIENTS AND METHODS: Subjects who had undergone pulmonary function examination in Beijing hospital from July 2003 to April 2015 were included in the study. Patients with FEV(1)<50% of the predicted value were classified as the severely lung function–impaired group. Correlation between the severity of lung function impairment and changes in FEV(1), FEV(3) and FVC in response to a bronchodilator was estimated. RESULTS: A total of 7745 tests on elderly subjects with a median age of 71 years were reviewed. The severely lung function–impaired group of 1728 accounted for 22.3% of the total number of subjects. There were significantly more patients in the severely lung function–impaired group who exhibited positive response in FEV(3) or FVC and negative response in FEV(1) after bronchodilator test (FEV(1) negative response but FVC positive response, χ2=626.97, P<0.001; FEV(1) negative response but FEV(3) positive response, χ2=372.83, P<0.001). With the progressive increase in lung function impairment, ΔFEV(1) increased and then declined, while ΔFVC and ΔFEV(3) increased progressively. Changes in FEV(3) or FVC significantly exceeded the change in FEV(1) in the severely lung function–impaired groups (P<0.001). CONCLUSION: In elderly subjects, especially those with severe lung function impairment, FEV(3) combined with FVC is a more effective and sensitive primary clinical outcome measure to detect bronchial reversibility. In subjects who cannot complete ≥6 s forced expiration and whose FVC is unreliable, FEV(3) combined with FEV(1) might be clinically more valuable in detecting bronchial reversibility. Dove 2019-08-07 /pmc/articles/PMC6689797/ /pubmed/31496679 http://dx.doi.org/10.2147/COPD.S197552 Text en © 2019 Pan et al. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php). |
spellingShingle | Original Research Pan, Mingming Zhang, Hongsheng Sun, Tieying Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title | Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title_full | Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title_fullStr | Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title_full_unstemmed | Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title_short | Forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly Chinese with severe lung function impairment |
title_sort | forced expiratory volumes in 3 s is a sensitive clinical measure for assessment of bronchodilator reversibility in elderly chinese with severe lung function impairment |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6689797/ https://www.ncbi.nlm.nih.gov/pubmed/31496679 http://dx.doi.org/10.2147/COPD.S197552 |
work_keys_str_mv | AT panmingming forcedexpiratoryvolumesin3sisasensitiveclinicalmeasureforassessmentofbronchodilatorreversibilityinelderlychinesewithseverelungfunctionimpairment AT zhanghongsheng forcedexpiratoryvolumesin3sisasensitiveclinicalmeasureforassessmentofbronchodilatorreversibilityinelderlychinesewithseverelungfunctionimpairment AT suntieying forcedexpiratoryvolumesin3sisasensitiveclinicalmeasureforassessmentofbronchodilatorreversibilityinelderlychinesewithseverelungfunctionimpairment |