Cargando…

Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion

Posterolateral spinal fusion (PLF) is a common procedure in orthopedic surgery that is performed to fuse adjacent vertebrae to reduce symptoms related to spinal conditions. In the current study, a novel synthetic calcium phosphate with submicron surface topography was evaluated as an autograft exten...

Descripción completa

Detalles Bibliográficos
Autores principales: van Dijk, Lukas A., Barbieri, Davide, Barrère‐de Groot, Florence, Yuan, Huipin, Oliver, Rema, Christou, Chris, Walsh, William R., de Bruijn, Joost D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6690075/
https://www.ncbi.nlm.nih.gov/pubmed/30614621
http://dx.doi.org/10.1002/jbm.b.34301
_version_ 1783443138741796864
author van Dijk, Lukas A.
Barbieri, Davide
Barrère‐de Groot, Florence
Yuan, Huipin
Oliver, Rema
Christou, Chris
Walsh, William R.
de Bruijn, Joost D.
author_facet van Dijk, Lukas A.
Barbieri, Davide
Barrère‐de Groot, Florence
Yuan, Huipin
Oliver, Rema
Christou, Chris
Walsh, William R.
de Bruijn, Joost D.
author_sort van Dijk, Lukas A.
collection PubMed
description Posterolateral spinal fusion (PLF) is a common procedure in orthopedic surgery that is performed to fuse adjacent vertebrae to reduce symptoms related to spinal conditions. In the current study, a novel synthetic calcium phosphate with submicron surface topography was evaluated as an autograft extender in a validated rabbit model of PLF. Fifty‐nine skeletally mature New Zealand white rabbits were divided into three groups and underwent single‐level intertransverse process PLF at L4‐5 using (1) autologous bone graft (ABG) alone or in a 1:1 combination with (2) calcium phosphate granules (ABG/BCP(granules)), or (3) granules embedded in a fast‐resorbing polymeric carrier (ABG/BCP(putty)). After 6, 9, and 12 weeks, animals were sacrificed and spinal fusion was assessed by manual palpation, Radiographs, micro‐CT, mechanical testing (12 weeks only), histology, and histomorphometry. Based on all endpoints, all groups showed a gradual progression in bone formation and maturation during time, leading to solid fusion masses between the transverse processes after 12 weeks. Fusion assessments by manual palpation, radiography and histology were consistent and demonstrated equivalent fusion rates between groups, with high bilateral fusion rates after 12 weeks. Mechanical tests after 12 weeks indicated substantially lower range of motion for all groups, compared to non‐operated controls. By histology and histomorphometry, the gradual formation and maturation of bone in the fusion mass was confirmed for each graft type. With these results, we describe the equivalent performance between autograft and a novel calcium phosphate material as an autograft extender in a rabbit model of PLF using an extensive range of evaluation techniques. © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2080–2090, 2019.
format Online
Article
Text
id pubmed-6690075
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-66900752019-08-15 Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion van Dijk, Lukas A. Barbieri, Davide Barrère‐de Groot, Florence Yuan, Huipin Oliver, Rema Christou, Chris Walsh, William R. de Bruijn, Joost D. J Biomed Mater Res B Appl Biomater Original Research Reports Posterolateral spinal fusion (PLF) is a common procedure in orthopedic surgery that is performed to fuse adjacent vertebrae to reduce symptoms related to spinal conditions. In the current study, a novel synthetic calcium phosphate with submicron surface topography was evaluated as an autograft extender in a validated rabbit model of PLF. Fifty‐nine skeletally mature New Zealand white rabbits were divided into three groups and underwent single‐level intertransverse process PLF at L4‐5 using (1) autologous bone graft (ABG) alone or in a 1:1 combination with (2) calcium phosphate granules (ABG/BCP(granules)), or (3) granules embedded in a fast‐resorbing polymeric carrier (ABG/BCP(putty)). After 6, 9, and 12 weeks, animals were sacrificed and spinal fusion was assessed by manual palpation, Radiographs, micro‐CT, mechanical testing (12 weeks only), histology, and histomorphometry. Based on all endpoints, all groups showed a gradual progression in bone formation and maturation during time, leading to solid fusion masses between the transverse processes after 12 weeks. Fusion assessments by manual palpation, radiography and histology were consistent and demonstrated equivalent fusion rates between groups, with high bilateral fusion rates after 12 weeks. Mechanical tests after 12 weeks indicated substantially lower range of motion for all groups, compared to non‐operated controls. By histology and histomorphometry, the gradual formation and maturation of bone in the fusion mass was confirmed for each graft type. With these results, we describe the equivalent performance between autograft and a novel calcium phosphate material as an autograft extender in a rabbit model of PLF using an extensive range of evaluation techniques. © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 2080–2090, 2019. John Wiley & Sons, Inc. 2019-01-07 2019-08 /pmc/articles/PMC6690075/ /pubmed/30614621 http://dx.doi.org/10.1002/jbm.b.34301 Text en © 2019 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Research Reports
van Dijk, Lukas A.
Barbieri, Davide
Barrère‐de Groot, Florence
Yuan, Huipin
Oliver, Rema
Christou, Chris
Walsh, William R.
de Bruijn, Joost D.
Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title_full Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title_fullStr Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title_full_unstemmed Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title_short Efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
title_sort efficacy of a synthetic calcium phosphate with submicron surface topography as autograft extender in lapine posterolateral spinal fusion
topic Original Research Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6690075/
https://www.ncbi.nlm.nih.gov/pubmed/30614621
http://dx.doi.org/10.1002/jbm.b.34301
work_keys_str_mv AT vandijklukasa efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT barbieridavide efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT barreredegrootflorence efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT yuanhuipin efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT oliverrema efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT christouchris efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT walshwilliamr efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion
AT debruijnjoostd efficacyofasyntheticcalciumphosphatewithsubmicronsurfacetopographyasautograftextenderinlapineposterolateralspinalfusion