Cargando…
Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis
Endostatin, the C-terminal fragment of type XVIII collagen, was shown to be one of the most potent endothelial cell-specific inhibitors of angiogenesis. As altered circulating endostatin concentration is associated with impaired kidney function, new tools for measuring endostatin in rodents may be h...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6690585/ https://www.ncbi.nlm.nih.gov/pubmed/31404120 http://dx.doi.org/10.1371/journal.pone.0220935 |
_version_ | 1783443214357757952 |
---|---|
author | Wallwitz, Jacqueline Aigner, Petra Gadermaier, Elisabeth Bauer, Eva Casanova, Emilio Bauer, Anton Stoiber, Dagmar |
author_facet | Wallwitz, Jacqueline Aigner, Petra Gadermaier, Elisabeth Bauer, Eva Casanova, Emilio Bauer, Anton Stoiber, Dagmar |
author_sort | Wallwitz, Jacqueline |
collection | PubMed |
description | Endostatin, the C-terminal fragment of type XVIII collagen, was shown to be one of the most potent endothelial cell-specific inhibitors of angiogenesis. As altered circulating endostatin concentration is associated with impaired kidney function, new tools for measuring endostatin in rodents may be helpful to further investigate and understand its role within kidney disease progression. A novel and commercially available ELISA for the quantification of mouse and rat endostatin was developed and validated according to international quality guidelines including the parameters specificity, robustness, accuracy, dilution linearity, precision, limit of detection (LOD) and lower limit of quantification (LLOQ). Endostatin and blood urea nitrogen (BUN) concentration were measured in mice with a glomerulonephritis phenotype. The validation revealed that within the range of 0.5–32 nmol/L the immunoassay is robust and highly specific for the measurement of rodent endostatin with high sensitivity (LOD 0.24 nmol/L, LLOQ 0.5 nmol/L) and good reproducibility (intra- and inter-assay CV <10%). Also accuracy and dilution linearity were within the range of acceptance. BCL2 transgenic and ETV6/RUNX1;BCL2 double transgenic mice develop a glomerulonephritis phenotype over time, which was displayed by staining of kidney sections. Even before full manifestation of disease serum endostatin concentration rises significantly, whereas BUN levels just slightly increase. This newly developed and commercially available ELISA provides a reliable and accurate tool for the quantification of mouse and rat endostatin and may give new perspectives in the investigation of the role of endostatin as an important and early biomarker for reduced kidney function. Measurement of endostatin concentration is recommended to be used as a superior biomarker for chronic kidney disease compared to BUN. |
format | Online Article Text |
id | pubmed-6690585 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-66905852019-08-15 Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis Wallwitz, Jacqueline Aigner, Petra Gadermaier, Elisabeth Bauer, Eva Casanova, Emilio Bauer, Anton Stoiber, Dagmar PLoS One Research Article Endostatin, the C-terminal fragment of type XVIII collagen, was shown to be one of the most potent endothelial cell-specific inhibitors of angiogenesis. As altered circulating endostatin concentration is associated with impaired kidney function, new tools for measuring endostatin in rodents may be helpful to further investigate and understand its role within kidney disease progression. A novel and commercially available ELISA for the quantification of mouse and rat endostatin was developed and validated according to international quality guidelines including the parameters specificity, robustness, accuracy, dilution linearity, precision, limit of detection (LOD) and lower limit of quantification (LLOQ). Endostatin and blood urea nitrogen (BUN) concentration were measured in mice with a glomerulonephritis phenotype. The validation revealed that within the range of 0.5–32 nmol/L the immunoassay is robust and highly specific for the measurement of rodent endostatin with high sensitivity (LOD 0.24 nmol/L, LLOQ 0.5 nmol/L) and good reproducibility (intra- and inter-assay CV <10%). Also accuracy and dilution linearity were within the range of acceptance. BCL2 transgenic and ETV6/RUNX1;BCL2 double transgenic mice develop a glomerulonephritis phenotype over time, which was displayed by staining of kidney sections. Even before full manifestation of disease serum endostatin concentration rises significantly, whereas BUN levels just slightly increase. This newly developed and commercially available ELISA provides a reliable and accurate tool for the quantification of mouse and rat endostatin and may give new perspectives in the investigation of the role of endostatin as an important and early biomarker for reduced kidney function. Measurement of endostatin concentration is recommended to be used as a superior biomarker for chronic kidney disease compared to BUN. Public Library of Science 2019-08-12 /pmc/articles/PMC6690585/ /pubmed/31404120 http://dx.doi.org/10.1371/journal.pone.0220935 Text en © 2019 Wallwitz et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Wallwitz, Jacqueline Aigner, Petra Gadermaier, Elisabeth Bauer, Eva Casanova, Emilio Bauer, Anton Stoiber, Dagmar Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title | Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title_full | Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title_fullStr | Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title_full_unstemmed | Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title_short | Validation of an enzyme-linked immunosorbent assay (ELISA) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
title_sort | validation of an enzyme-linked immunosorbent assay (elisa) for quantification of endostatin levels in mice as a biomarker of developing glomerulonephritis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6690585/ https://www.ncbi.nlm.nih.gov/pubmed/31404120 http://dx.doi.org/10.1371/journal.pone.0220935 |
work_keys_str_mv | AT wallwitzjacqueline validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT aignerpetra validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT gadermaierelisabeth validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT bauereva validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT casanovaemilio validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT baueranton validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis AT stoiberdagmar validationofanenzymelinkedimmunosorbentassayelisaforquantificationofendostatinlevelsinmiceasabiomarkerofdevelopingglomerulonephritis |