Cargando…

Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study

BACKGROUND: This study aims to assess the changes in lung aeration and ventilation during the first spontaneous breathing trial (SBT) and after extubation in a population of patients at risk of extubation failure. METHODS: We included 78 invasively ventilated patients eligible for their first SBT, c...

Descripción completa

Detalles Bibliográficos
Autores principales: Longhini, Federico, Maugeri, Jessica, Andreoni, Cristina, Ronco, Chiara, Bruni, Andrea, Garofalo, Eugenio, Pelaia, Corrado, Cavicchi, Camilla, Pintaudi, Sergio, Navalesi, Paolo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692788/
https://www.ncbi.nlm.nih.gov/pubmed/31410738
http://dx.doi.org/10.1186/s13613-019-0565-0
_version_ 1783443603691929600
author Longhini, Federico
Maugeri, Jessica
Andreoni, Cristina
Ronco, Chiara
Bruni, Andrea
Garofalo, Eugenio
Pelaia, Corrado
Cavicchi, Camilla
Pintaudi, Sergio
Navalesi, Paolo
author_facet Longhini, Federico
Maugeri, Jessica
Andreoni, Cristina
Ronco, Chiara
Bruni, Andrea
Garofalo, Eugenio
Pelaia, Corrado
Cavicchi, Camilla
Pintaudi, Sergio
Navalesi, Paolo
author_sort Longhini, Federico
collection PubMed
description BACKGROUND: This study aims to assess the changes in lung aeration and ventilation during the first spontaneous breathing trial (SBT) and after extubation in a population of patients at risk of extubation failure. METHODS: We included 78 invasively ventilated patients eligible for their first SBT, conducted with low positive end-expiratory pressure (2 cm H(2)O) for 30 min. We acquired three 5-min electrical impedance tomography (EIT) records at baseline, soon after the beginning (SBT_0) and at the end (SBT_30) of SBT. In the case of SBT failure, ventilation was reinstituted; otherwise, the patient was extubated and two additional records were acquired soon after extubation (SB_0) and 30 min later (SB_30) during spontaneous breathing. Extubation failure was defined by the onset of post-extubation respiratory failure within 48 h after extubation. We computed the changes from baseline of end-expiratory lung impedance (∆EELI), tidal volume (∆Vt%), and the inhomogeneity index. Arterial blood was sampled for gas analysis. Data were compared between sub-groups stratified for SBT and extubation success/failure. RESULTS: Compared to SBT success (n = 61), SBT failure (n = 17) showed a greater reduction in ∆EELI at SBT_0 (p < 0.001) and SBT_30 (p = 0.001) and a higher inhomogeneity index at baseline (p = 0.002), SBT_0 (p = 0.003) and SBT_30 (p = 0.005). RR/Vt was not different between groups at baseline but was significantly greater at SBT_0 and SBT_30 in SBT failures, compared to SBT successes (p < 0.001 for both). No differences in ∆Vt% and arterial blood gases were observed between SBT success and failure. The ∆Vt%, ∆EELI, inhomogeneity index and arterial blood gases were not different between patients with extubation success (n = 39) and failure (n = 22) (p > 0.05 for all comparisons). CONCLUSIONS: Compared to SBT success, SBT failure was characterized by more lung de-recruitment and inhomogeneity. Whether EIT may be useful to monitor SBT remains to be determined. No significant changes in lung ventilation, aeration or homogeneity related to extubation outcome occurred up to 30 min after extubation. Trial registration Retrospectively registered on clinicaltrials.gov (Identifier: NCT03894332; release date 27th March 2019). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-019-0565-0) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-6692788
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-66927882019-08-28 Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study Longhini, Federico Maugeri, Jessica Andreoni, Cristina Ronco, Chiara Bruni, Andrea Garofalo, Eugenio Pelaia, Corrado Cavicchi, Camilla Pintaudi, Sergio Navalesi, Paolo Ann Intensive Care Research BACKGROUND: This study aims to assess the changes in lung aeration and ventilation during the first spontaneous breathing trial (SBT) and after extubation in a population of patients at risk of extubation failure. METHODS: We included 78 invasively ventilated patients eligible for their first SBT, conducted with low positive end-expiratory pressure (2 cm H(2)O) for 30 min. We acquired three 5-min electrical impedance tomography (EIT) records at baseline, soon after the beginning (SBT_0) and at the end (SBT_30) of SBT. In the case of SBT failure, ventilation was reinstituted; otherwise, the patient was extubated and two additional records were acquired soon after extubation (SB_0) and 30 min later (SB_30) during spontaneous breathing. Extubation failure was defined by the onset of post-extubation respiratory failure within 48 h after extubation. We computed the changes from baseline of end-expiratory lung impedance (∆EELI), tidal volume (∆Vt%), and the inhomogeneity index. Arterial blood was sampled for gas analysis. Data were compared between sub-groups stratified for SBT and extubation success/failure. RESULTS: Compared to SBT success (n = 61), SBT failure (n = 17) showed a greater reduction in ∆EELI at SBT_0 (p < 0.001) and SBT_30 (p = 0.001) and a higher inhomogeneity index at baseline (p = 0.002), SBT_0 (p = 0.003) and SBT_30 (p = 0.005). RR/Vt was not different between groups at baseline but was significantly greater at SBT_0 and SBT_30 in SBT failures, compared to SBT successes (p < 0.001 for both). No differences in ∆Vt% and arterial blood gases were observed between SBT success and failure. The ∆Vt%, ∆EELI, inhomogeneity index and arterial blood gases were not different between patients with extubation success (n = 39) and failure (n = 22) (p > 0.05 for all comparisons). CONCLUSIONS: Compared to SBT success, SBT failure was characterized by more lung de-recruitment and inhomogeneity. Whether EIT may be useful to monitor SBT remains to be determined. No significant changes in lung ventilation, aeration or homogeneity related to extubation outcome occurred up to 30 min after extubation. Trial registration Retrospectively registered on clinicaltrials.gov (Identifier: NCT03894332; release date 27th March 2019). ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s13613-019-0565-0) contains supplementary material, which is available to authorized users. Springer International Publishing 2019-08-13 /pmc/articles/PMC6692788/ /pubmed/31410738 http://dx.doi.org/10.1186/s13613-019-0565-0 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Longhini, Federico
Maugeri, Jessica
Andreoni, Cristina
Ronco, Chiara
Bruni, Andrea
Garofalo, Eugenio
Pelaia, Corrado
Cavicchi, Camilla
Pintaudi, Sergio
Navalesi, Paolo
Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title_full Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title_fullStr Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title_full_unstemmed Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title_short Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
title_sort electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692788/
https://www.ncbi.nlm.nih.gov/pubmed/31410738
http://dx.doi.org/10.1186/s13613-019-0565-0
work_keys_str_mv AT longhinifederico electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT maugerijessica electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT andreonicristina electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT roncochiara electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT bruniandrea electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT garofaloeugenio electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT pelaiacorrado electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT cavicchicamilla electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT pintaudisergio electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy
AT navalesipaolo electricalimpedancetomographyduringspontaneousbreathingtrialsandafterextubationincriticallyillpatientsathighriskforextubationfailureamulticenterobservationalstudy