Cargando…

The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study

INTRODUCTION: To evaluate the effects of cycloplegia on the biometric components and anterior segment parameters of the eye. METHODS: In this cross-sectional study, changes to axial length (AL), anterior chamber depth (ACD) lens thickness, anterior chamber angle (ACA) and volume, corneal thickness i...

Descripción completa

Detalles Bibliográficos
Autores principales: Momeni-Moghaddam, Hamed, Maddah, Nasim, Wolffsohn, James S., Etezad-Razavi, Mohammad, Zarei-Ghanavati, Siamak, Akhavan Rezayat, Amir, Moshirfar, Majid
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Healthcare 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692795/
https://www.ncbi.nlm.nih.gov/pubmed/31054123
http://dx.doi.org/10.1007/s40123-019-0187-5
_version_ 1783443605383282688
author Momeni-Moghaddam, Hamed
Maddah, Nasim
Wolffsohn, James S.
Etezad-Razavi, Mohammad
Zarei-Ghanavati, Siamak
Akhavan Rezayat, Amir
Moshirfar, Majid
author_facet Momeni-Moghaddam, Hamed
Maddah, Nasim
Wolffsohn, James S.
Etezad-Razavi, Mohammad
Zarei-Ghanavati, Siamak
Akhavan Rezayat, Amir
Moshirfar, Majid
author_sort Momeni-Moghaddam, Hamed
collection PubMed
description INTRODUCTION: To evaluate the effects of cycloplegia on the biometric components and anterior segment parameters of the eye. METHODS: In this cross-sectional study, changes to axial length (AL), anterior chamber depth (ACD) lens thickness, anterior chamber angle (ACA) and volume, corneal thickness in the pupil center (PC), corneal curvature (CC) and white-to-white (WTW) following cycloplegia induced by tropicamide 1% in 42 eyes of patients aged 23–58 years were assessed. Biometric components and anterior segment parameters were measured using an IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany) and a Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany), respectively. RESULTS: Significant statistical changes in ACD (increased by 0.06 ± 0.05 mm; p < 0.001), anterior chamber volume (increased by 15.19 ± 10.32 mm(3); p < 0.001), ACA (decreased by 2.18 ± 10.20°; p = 0.029) and lens thickness (decreased by 0.02 ± 0.03 mm; p < 0.001) were observed post-cycloplegia, while the changes in CC, corneal thickness in the PC, WTW and AL were not statistically different (p > 0.05). Also, a significant inferior displacement of the PC along the vertical axes was seen (p = 0.020). CONCLUSION: Cycloplegia resulted in a deeper ACD and thinner lens thickness. These changes should be considered in determining intraocular lens (IOL) power to prevent refractive surprises in cataract surgery and also in the phakic IOL implantation.
format Online
Article
Text
id pubmed-6692795
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Healthcare
record_format MEDLINE/PubMed
spelling pubmed-66927952019-08-26 The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study Momeni-Moghaddam, Hamed Maddah, Nasim Wolffsohn, James S. Etezad-Razavi, Mohammad Zarei-Ghanavati, Siamak Akhavan Rezayat, Amir Moshirfar, Majid Ophthalmol Ther Original Research INTRODUCTION: To evaluate the effects of cycloplegia on the biometric components and anterior segment parameters of the eye. METHODS: In this cross-sectional study, changes to axial length (AL), anterior chamber depth (ACD) lens thickness, anterior chamber angle (ACA) and volume, corneal thickness in the pupil center (PC), corneal curvature (CC) and white-to-white (WTW) following cycloplegia induced by tropicamide 1% in 42 eyes of patients aged 23–58 years were assessed. Biometric components and anterior segment parameters were measured using an IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany) and a Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany), respectively. RESULTS: Significant statistical changes in ACD (increased by 0.06 ± 0.05 mm; p < 0.001), anterior chamber volume (increased by 15.19 ± 10.32 mm(3); p < 0.001), ACA (decreased by 2.18 ± 10.20°; p = 0.029) and lens thickness (decreased by 0.02 ± 0.03 mm; p < 0.001) were observed post-cycloplegia, while the changes in CC, corneal thickness in the PC, WTW and AL were not statistically different (p > 0.05). Also, a significant inferior displacement of the PC along the vertical axes was seen (p = 0.020). CONCLUSION: Cycloplegia resulted in a deeper ACD and thinner lens thickness. These changes should be considered in determining intraocular lens (IOL) power to prevent refractive surprises in cataract surgery and also in the phakic IOL implantation. Springer Healthcare 2019-05-03 2019-09 /pmc/articles/PMC6692795/ /pubmed/31054123 http://dx.doi.org/10.1007/s40123-019-0187-5 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits any noncommercial use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Momeni-Moghaddam, Hamed
Maddah, Nasim
Wolffsohn, James S.
Etezad-Razavi, Mohammad
Zarei-Ghanavati, Siamak
Akhavan Rezayat, Amir
Moshirfar, Majid
The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title_full The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title_fullStr The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title_full_unstemmed The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title_short The Effect of Cycloplegia on the Ocular Biometric and Anterior Segment Parameters: A Cross-Sectional Study
title_sort effect of cycloplegia on the ocular biometric and anterior segment parameters: a cross-sectional study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692795/
https://www.ncbi.nlm.nih.gov/pubmed/31054123
http://dx.doi.org/10.1007/s40123-019-0187-5
work_keys_str_mv AT momenimoghaddamhamed theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT maddahnasim theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT wolffsohnjamess theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT etezadrazavimohammad theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT zareighanavatisiamak theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT akhavanrezayatamir theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT moshirfarmajid theeffectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT momenimoghaddamhamed effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT maddahnasim effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT wolffsohnjamess effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT etezadrazavimohammad effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT zareighanavatisiamak effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT akhavanrezayatamir effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy
AT moshirfarmajid effectofcycloplegiaontheocularbiometricandanteriorsegmentparametersacrosssectionalstudy