Cargando…

Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate

BACKGROUND: Application of an endorectal coil (ERC) for 3.0-T prostate magnetic resonance imaging (MRI) is contentious. We hypothesised that a multicoil phased-array protocol provides T2-weighted images (T2WI) and diffusion-weighted images (DWI) with reduced field-of-view (DWI(reduced)) and monoexpo...

Descripción completa

Detalles Bibliográficos
Autores principales: Murer, Sophie, Scheidler, Juergen, Mueller-Lisse, Ulrike L., Helling, Marissa, Scherr, Michael, Mueller-Lisse, Ullrich G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692805/
https://www.ncbi.nlm.nih.gov/pubmed/31410699
http://dx.doi.org/10.1186/s41747-019-0111-8
_version_ 1783443607786618880
author Murer, Sophie
Scheidler, Juergen
Mueller-Lisse, Ulrike L.
Helling, Marissa
Scherr, Michael
Mueller-Lisse, Ullrich G.
author_facet Murer, Sophie
Scheidler, Juergen
Mueller-Lisse, Ulrike L.
Helling, Marissa
Scherr, Michael
Mueller-Lisse, Ullrich G.
author_sort Murer, Sophie
collection PubMed
description BACKGROUND: Application of an endorectal coil (ERC) for 3.0-T prostate magnetic resonance imaging (MRI) is contentious. We hypothesised that a multicoil phased-array protocol provides T2-weighted images (T2WI) and diffusion-weighted images (DWI) with reduced field-of-view (DWI(reduced)) and monoexponential apparent diffusion coefficient (ADC) maps that are technically equivalent with ERC or without ERC (noERC). METHODS: Axial T2WI (repetition time [TR] 7500 ms, echo time [TE] 98–101 ms) and DWI(reduced) (field-of-view 149–179 × 71–73 mm(2), TR/TE 4500–5500/61–74 ms, b values, 50/800 s/mm(2)) ERC and noERC images were obtained on identical clinical 3.0-T scanners at two centres and compared for signal-to-noise ratio (SNR) in anterior and posterior outer pericarp (OP) and peripheral placenta (PP) in five green Hayward kiwifruit (Actinidia deliciosa, European Union regulation 543/2011 class 2). Corroboration in 21 patients with benign prostate hyperplasia (negative biopsy, prostate imaging reporting and data system version 2 ≤ 2) involved identical MRI protocols: 10 at site 1, noERC, and 11 at site 2, with ERC. Two-tailed Student’s t test was used. RESULTS: With few exceptions, signal-to-noise ratio (SNR) was similar in kiwifruits and prostates for ERC and noERC. In T2WI, SNR was higher posteriorly in noERC MRI for peripheral zone (PZ) (p < 0.001). In DWI(reduced), SNR was higher posteriorly in ERC-OP (p = 0.013) and ERC-PZ (p = 0.026) for b = 50 s/mm(2); noERC-OP (p = 0.044) and ERC-PZ (p = 0.001) for b = 800 s/mm(2); and ERC-OP (p = 0.001), noERC-OP (p = 0.001), and ERC-PZ (p = 0.001) for ADC, respectively. Volumes of kiwifruits and prostates were similar (89.2 ± 11.2 versus 90.8 ± 48.5 cm(3), p = 0.638–0.920). CONCLUSIONS: Findings imply that multicoil phased-array 3.0-T prostate MRI with T2WI and DWI(reduced) with ADC maps provides equivalent results with and without ERC.
format Online
Article
Text
id pubmed-6692805
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-66928052019-08-28 Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate Murer, Sophie Scheidler, Juergen Mueller-Lisse, Ulrike L. Helling, Marissa Scherr, Michael Mueller-Lisse, Ullrich G. Eur Radiol Exp Original Article BACKGROUND: Application of an endorectal coil (ERC) for 3.0-T prostate magnetic resonance imaging (MRI) is contentious. We hypothesised that a multicoil phased-array protocol provides T2-weighted images (T2WI) and diffusion-weighted images (DWI) with reduced field-of-view (DWI(reduced)) and monoexponential apparent diffusion coefficient (ADC) maps that are technically equivalent with ERC or without ERC (noERC). METHODS: Axial T2WI (repetition time [TR] 7500 ms, echo time [TE] 98–101 ms) and DWI(reduced) (field-of-view 149–179 × 71–73 mm(2), TR/TE 4500–5500/61–74 ms, b values, 50/800 s/mm(2)) ERC and noERC images were obtained on identical clinical 3.0-T scanners at two centres and compared for signal-to-noise ratio (SNR) in anterior and posterior outer pericarp (OP) and peripheral placenta (PP) in five green Hayward kiwifruit (Actinidia deliciosa, European Union regulation 543/2011 class 2). Corroboration in 21 patients with benign prostate hyperplasia (negative biopsy, prostate imaging reporting and data system version 2 ≤ 2) involved identical MRI protocols: 10 at site 1, noERC, and 11 at site 2, with ERC. Two-tailed Student’s t test was used. RESULTS: With few exceptions, signal-to-noise ratio (SNR) was similar in kiwifruits and prostates for ERC and noERC. In T2WI, SNR was higher posteriorly in noERC MRI for peripheral zone (PZ) (p < 0.001). In DWI(reduced), SNR was higher posteriorly in ERC-OP (p = 0.013) and ERC-PZ (p = 0.026) for b = 50 s/mm(2); noERC-OP (p = 0.044) and ERC-PZ (p = 0.001) for b = 800 s/mm(2); and ERC-OP (p = 0.001), noERC-OP (p = 0.001), and ERC-PZ (p = 0.001) for ADC, respectively. Volumes of kiwifruits and prostates were similar (89.2 ± 11.2 versus 90.8 ± 48.5 cm(3), p = 0.638–0.920). CONCLUSIONS: Findings imply that multicoil phased-array 3.0-T prostate MRI with T2WI and DWI(reduced) with ADC maps provides equivalent results with and without ERC. Springer International Publishing 2019-08-14 /pmc/articles/PMC6692805/ /pubmed/31410699 http://dx.doi.org/10.1186/s41747-019-0111-8 Text en © The Author(s) 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Murer, Sophie
Scheidler, Juergen
Mueller-Lisse, Ulrike L.
Helling, Marissa
Scherr, Michael
Mueller-Lisse, Ullrich G.
Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title_full Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title_fullStr Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title_full_unstemmed Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title_short Two-centre comparative experimental study of biparametric MRI at 3.0 T with and without endorectal coil using kiwifruit (Actinidia deliciosa) as a phantom for human prostate
title_sort two-centre comparative experimental study of biparametric mri at 3.0 t with and without endorectal coil using kiwifruit (actinidia deliciosa) as a phantom for human prostate
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6692805/
https://www.ncbi.nlm.nih.gov/pubmed/31410699
http://dx.doi.org/10.1186/s41747-019-0111-8
work_keys_str_mv AT murersophie twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate
AT scheidlerjuergen twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate
AT muellerlisseulrikel twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate
AT hellingmarissa twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate
AT scherrmichael twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate
AT muellerlisseullrichg twocentrecomparativeexperimentalstudyofbiparametricmriat30twithandwithoutendorectalcoilusingkiwifruitactinidiadeliciosaasaphantomforhumanprostate