Cargando…
Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693247/ https://www.ncbi.nlm.nih.gov/pubmed/31409385 http://dx.doi.org/10.1186/s12886-019-1194-y |
_version_ | 1783443675525677056 |
---|---|
author | Wan, Ting Yin, Houfa Yang, Yi Wu, Fang Wu, Zhiyi Yang, Yabo |
author_facet | Wan, Ting Yin, Houfa Yang, Yi Wu, Fang Wu, Zhiyi Yang, Yabo |
author_sort | Wan, Ting |
collection | PubMed |
description | BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot. RESULTS: AS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, − 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, − 0.03 to 0.33 mm, − 0.16 to 0.31 mm, − 0.10 to 0.26 mm between AS-OCT and UBM, and − 0.29 to 0.07 mm, − 0.25 to 0.20 mm, − 0.31 to 0.05 mm between Pentacam and UBM, respectively. CONCLUSIONS: AS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices. TRIAL REGISTRATION: Registration number: ChiCTR-OOC-16008987. Retrospectively registered: 08 August 2016. |
format | Online Article Text |
id | pubmed-6693247 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-66932472019-08-19 Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation Wan, Ting Yin, Houfa Yang, Yi Wu, Fang Wu, Zhiyi Yang, Yabo BMC Ophthalmol Research Article BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot. RESULTS: AS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, − 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, − 0.03 to 0.33 mm, − 0.16 to 0.31 mm, − 0.10 to 0.26 mm between AS-OCT and UBM, and − 0.29 to 0.07 mm, − 0.25 to 0.20 mm, − 0.31 to 0.05 mm between Pentacam and UBM, respectively. CONCLUSIONS: AS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices. TRIAL REGISTRATION: Registration number: ChiCTR-OOC-16008987. Retrospectively registered: 08 August 2016. BioMed Central 2019-08-13 /pmc/articles/PMC6693247/ /pubmed/31409385 http://dx.doi.org/10.1186/s12886-019-1194-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Wan, Ting Yin, Houfa Yang, Yi Wu, Fang Wu, Zhiyi Yang, Yabo Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title | Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title_full | Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title_fullStr | Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title_full_unstemmed | Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title_short | Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation |
title_sort | comparative study of anterior segment measurements using 3 different instruments in myopic patients after icl implantation |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693247/ https://www.ncbi.nlm.nih.gov/pubmed/31409385 http://dx.doi.org/10.1186/s12886-019-1194-y |
work_keys_str_mv | AT wanting comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation AT yinhoufa comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation AT yangyi comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation AT wufang comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation AT wuzhiyi comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation AT yangyabo comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation |