Cargando…

Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation

BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between c...

Descripción completa

Detalles Bibliográficos
Autores principales: Wan, Ting, Yin, Houfa, Yang, Yi, Wu, Fang, Wu, Zhiyi, Yang, Yabo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693247/
https://www.ncbi.nlm.nih.gov/pubmed/31409385
http://dx.doi.org/10.1186/s12886-019-1194-y
_version_ 1783443675525677056
author Wan, Ting
Yin, Houfa
Yang, Yi
Wu, Fang
Wu, Zhiyi
Yang, Yabo
author_facet Wan, Ting
Yin, Houfa
Yang, Yi
Wu, Fang
Wu, Zhiyi
Yang, Yabo
author_sort Wan, Ting
collection PubMed
description BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot. RESULTS: AS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, − 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, − 0.03 to 0.33 mm, − 0.16 to 0.31 mm, − 0.10 to 0.26 mm between AS-OCT and UBM, and − 0.29 to 0.07 mm, − 0.25 to 0.20 mm, − 0.31 to 0.05 mm between Pentacam and UBM, respectively. CONCLUSIONS: AS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices. TRIAL REGISTRATION: Registration number: ChiCTR-OOC-16008987. Retrospectively registered: 08 August 2016.
format Online
Article
Text
id pubmed-6693247
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-66932472019-08-19 Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation Wan, Ting Yin, Houfa Yang, Yi Wu, Fang Wu, Zhiyi Yang, Yabo BMC Ophthalmol Research Article BACKGROUND: To compare and correlate anterior segment measurements of myopic eyes implanted with Implantable Collamer lens (ICL V4c) by using anterior segment optical coherence tomography (AS-OCT), Pentacam and ultrasound biomicroscopy (UBM). METHODS: Anterior chamber depth (ACD), distance between corneal endothelium and anterior surface of ICL(C-ICL) and central vault were measured in 82 phakic myopic eyes of 82 patients who underwent ICL surgery, by using AS-OCT, Pentacam and UBM consecutively at 3 months follow up. The correlation and agreement of instruments were accessed by using Intraclass correlation coefficient (ICC) and the Bland-Altman plot. RESULTS: AS-OCT showed higher ACD, C -ICL and central vault measurements than both of Pentacam and UBM (P < 0.001), while Pentacam showed lower measurements than UBM (P < 0.05). The Pearson correlation coefficient (r) was 0.91 to 0.96, and ICC was 0.95 to 0.98 for all measurements between difference devices (all P < 0.001). The 95% limits of agreement of ACD, C-ICL, vault measurements were 0.13 to 0.38 mm, − 0.07 to 0.27 mm, 0.08 to 0.34 mm between AS-OCT and Pentacam, − 0.03 to 0.33 mm, − 0.16 to 0.31 mm, − 0.10 to 0.26 mm between AS-OCT and UBM, and − 0.29 to 0.07 mm, − 0.25 to 0.20 mm, − 0.31 to 0.05 mm between Pentacam and UBM, respectively. CONCLUSIONS: AS-OCT demonstrated significantly higher value, while Pentacam demonstrated significantly lower value than UBM for ACD, C-ICL and central vault measurements in myopic eyes after ICL surgery. Measurements with these instruments were highly correlated, but could not replace each other especially for vault. This study provided valuable information about how to judge the results of anterior segment parameters of eyes implanted with ICL V4c from different devices. TRIAL REGISTRATION: Registration number: ChiCTR-OOC-16008987. Retrospectively registered: 08 August 2016. BioMed Central 2019-08-13 /pmc/articles/PMC6693247/ /pubmed/31409385 http://dx.doi.org/10.1186/s12886-019-1194-y Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Wan, Ting
Yin, Houfa
Yang, Yi
Wu, Fang
Wu, Zhiyi
Yang, Yabo
Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title_full Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title_fullStr Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title_full_unstemmed Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title_short Comparative study of anterior segment measurements using 3 different instruments in myopic patients after ICL implantation
title_sort comparative study of anterior segment measurements using 3 different instruments in myopic patients after icl implantation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693247/
https://www.ncbi.nlm.nih.gov/pubmed/31409385
http://dx.doi.org/10.1186/s12886-019-1194-y
work_keys_str_mv AT wanting comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation
AT yinhoufa comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation
AT yangyi comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation
AT wufang comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation
AT wuzhiyi comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation
AT yangyabo comparativestudyofanteriorsegmentmeasurementsusing3differentinstrumentsinmyopicpatientsaftericlimplantation