How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research
OBJECTIVE: Organ radiation dose from a CT scan, calculated by CT dosimetry software, can be combined with cancer risk data to estimate cancer incidence resulting from CT exposure. We aim to determine to what extent the use of improved anatomical representation of the adult human body “phantom” in CT...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693687/ https://www.ncbi.nlm.nih.gov/pubmed/31412037 http://dx.doi.org/10.1371/journal.pone.0217816 |
_version_ | 1783443723489640448 |
---|---|
author | Maxwell, Susannah Fox, Richard McRobbie, Donald Bulsara, Max Doust, Jenny O’Leary, Peter Slavotinek, John Stubbs, John Moorin, Rachael |
author_facet | Maxwell, Susannah Fox, Richard McRobbie, Donald Bulsara, Max Doust, Jenny O’Leary, Peter Slavotinek, John Stubbs, John Moorin, Rachael |
author_sort | Maxwell, Susannah |
collection | PubMed |
description | OBJECTIVE: Organ radiation dose from a CT scan, calculated by CT dosimetry software, can be combined with cancer risk data to estimate cancer incidence resulting from CT exposure. We aim to determine to what extent the use of improved anatomical representation of the adult human body “phantom” in CT dosimetry software impacts estimates of radiation dose and cancer incidence, to inform comparison of past and future research. METHODS: We collected 20 adult cases for each of three CT protocols (abdomen/pelvis, chest and head) from each of five public hospitals (random sample) (January-April inclusive 2010) and three private clinics (self-report). Organ equivalent and effective dose were calculated using both ImPACT (mathematical phantom) and NCICT (voxelised phantom) software. Bland-Altman plots demonstrate agreement and Passing-Bablok regression reports systematic, proportional or random differences between results. We modelled the estimated lifetime attributable risk of cancer from a single exposure for each protocol, using age-sex specific risk-coefficients from the Biologic Effects of Ionizing Radiation VII report. RESULTS: For the majority of organs used in epidemiological studies of cancer incidence, the NCICT software (voxelised) provided higher dose estimates. Across the lifespan NCICT resulted in cancer estimates 2.9%-6.6% and 14.8%-16.3% higher in males and females (abdomen/pelvis) and 7.6%-19.7% and 12.9%-26.5% higher in males and females respectively (chest protocol). For the head protocol overall cancer estimates were lower for NCICT, but with greatest disparity, >30% at times. CONCLUSION: When the results of previous studies estimating CT dose and cancer incidence are compared to more recent, or future, studies the dosimetry software must be considered. Any change in radiation dose or cancer risk may be attributable to the software and phantom used, rather than—or in addition to—changes in scanning practice. Studies using dosimetry software to estimate radiation dose should describe software comprehensively to facilitate comparison with past and future research. |
format | Online Article Text |
id | pubmed-6693687 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-66936872019-08-16 How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research Maxwell, Susannah Fox, Richard McRobbie, Donald Bulsara, Max Doust, Jenny O’Leary, Peter Slavotinek, John Stubbs, John Moorin, Rachael PLoS One Research Article OBJECTIVE: Organ radiation dose from a CT scan, calculated by CT dosimetry software, can be combined with cancer risk data to estimate cancer incidence resulting from CT exposure. We aim to determine to what extent the use of improved anatomical representation of the adult human body “phantom” in CT dosimetry software impacts estimates of radiation dose and cancer incidence, to inform comparison of past and future research. METHODS: We collected 20 adult cases for each of three CT protocols (abdomen/pelvis, chest and head) from each of five public hospitals (random sample) (January-April inclusive 2010) and three private clinics (self-report). Organ equivalent and effective dose were calculated using both ImPACT (mathematical phantom) and NCICT (voxelised phantom) software. Bland-Altman plots demonstrate agreement and Passing-Bablok regression reports systematic, proportional or random differences between results. We modelled the estimated lifetime attributable risk of cancer from a single exposure for each protocol, using age-sex specific risk-coefficients from the Biologic Effects of Ionizing Radiation VII report. RESULTS: For the majority of organs used in epidemiological studies of cancer incidence, the NCICT software (voxelised) provided higher dose estimates. Across the lifespan NCICT resulted in cancer estimates 2.9%-6.6% and 14.8%-16.3% higher in males and females (abdomen/pelvis) and 7.6%-19.7% and 12.9%-26.5% higher in males and females respectively (chest protocol). For the head protocol overall cancer estimates were lower for NCICT, but with greatest disparity, >30% at times. CONCLUSION: When the results of previous studies estimating CT dose and cancer incidence are compared to more recent, or future, studies the dosimetry software must be considered. Any change in radiation dose or cancer risk may be attributable to the software and phantom used, rather than—or in addition to—changes in scanning practice. Studies using dosimetry software to estimate radiation dose should describe software comprehensively to facilitate comparison with past and future research. Public Library of Science 2019-08-14 /pmc/articles/PMC6693687/ /pubmed/31412037 http://dx.doi.org/10.1371/journal.pone.0217816 Text en © 2019 Maxwell et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Maxwell, Susannah Fox, Richard McRobbie, Donald Bulsara, Max Doust, Jenny O’Leary, Peter Slavotinek, John Stubbs, John Moorin, Rachael How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title | How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title_full | How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title_fullStr | How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title_full_unstemmed | How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title_short | How have advances in CT dosimetry software impacted estimates of CT radiation dose and cancer incidence? A comparison of CT dosimetry software: Implications for past and future research |
title_sort | how have advances in ct dosimetry software impacted estimates of ct radiation dose and cancer incidence? a comparison of ct dosimetry software: implications for past and future research |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6693687/ https://www.ncbi.nlm.nih.gov/pubmed/31412037 http://dx.doi.org/10.1371/journal.pone.0217816 |
work_keys_str_mv | AT maxwellsusannah howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT foxrichard howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT mcrobbiedonald howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT bulsaramax howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT doustjenny howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT olearypeter howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT slavotinekjohn howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT stubbsjohn howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch AT moorinrachael howhaveadvancesinctdosimetrysoftwareimpactedestimatesofctradiationdoseandcancerincidenceacomparisonofctdosimetrysoftwareimplicationsforpastandfutureresearch |