Cargando…
Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using I...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695386/ https://www.ncbi.nlm.nih.gov/pubmed/31417149 http://dx.doi.org/10.1038/s41598-019-48386-9 |
_version_ | 1783444027664760832 |
---|---|
author | Park, Jun-Young Lee, Yonggu Choi, Yeon-Woo Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo |
author_facet | Park, Jun-Young Lee, Yonggu Choi, Yeon-Woo Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo |
author_sort | Park, Jun-Young |
collection | PubMed |
description | There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice. |
format | Online Article Text |
id | pubmed-6695386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-66953862019-08-19 Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar Park, Jun-Young Lee, Yonggu Choi, Yeon-Woo Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo Sci Rep Article There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice. Nature Publishing Group UK 2019-08-15 /pmc/articles/PMC6695386/ /pubmed/31417149 http://dx.doi.org/10.1038/s41598-019-48386-9 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article Park, Jun-Young Lee, Yonggu Choi, Yeon-Woo Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title | Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title_full | Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title_fullStr | Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title_full_unstemmed | Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title_short | Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar |
title_sort | preclinical evaluation of a noncontact simultaneous monitoring method for respiration and carotid pulsation using impulse-radio ultra-wideband radar |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695386/ https://www.ncbi.nlm.nih.gov/pubmed/31417149 http://dx.doi.org/10.1038/s41598-019-48386-9 |
work_keys_str_mv | AT parkjunyoung preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT leeyonggu preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT choiyeonwoo preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT heoran preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT parkhyunkyung preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT choseokhyun preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT chosungho preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar AT limyounghyo preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar |