Cargando…

Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar

There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using I...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jun-Young, Lee, Yonggu, Choi, Yeon-Woo, Heo, Ran, Park, Hyun-Kyung, Cho, Seok-Hyun, Cho, Sung Ho, Lim, Young-Hyo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695386/
https://www.ncbi.nlm.nih.gov/pubmed/31417149
http://dx.doi.org/10.1038/s41598-019-48386-9
_version_ 1783444027664760832
author Park, Jun-Young
Lee, Yonggu
Choi, Yeon-Woo
Heo, Ran
Park, Hyun-Kyung
Cho, Seok-Hyun
Cho, Sung Ho
Lim, Young-Hyo
author_facet Park, Jun-Young
Lee, Yonggu
Choi, Yeon-Woo
Heo, Ran
Park, Hyun-Kyung
Cho, Seok-Hyun
Cho, Sung Ho
Lim, Young-Hyo
author_sort Park, Jun-Young
collection PubMed
description There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice.
format Online
Article
Text
id pubmed-6695386
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-66953862019-08-19 Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar Park, Jun-Young Lee, Yonggu Choi, Yeon-Woo Heo, Ran Park, Hyun-Kyung Cho, Seok-Hyun Cho, Sung Ho Lim, Young-Hyo Sci Rep Article There has been the possibility for respiration and carotid pulsation to be simultaneously monitored from a distance using impulse-radio ultra-wideband (IR-UWB) radar. Therefore, we investigated the validity of simultaneous respiratory rates (RR), pulse rates (PR) and R-R interval measurement using IR-UWB radar. We included 19 patients with a normal sinus rhythm (NSR) and 14 patients with persistent atrial fibrillation (PeAF). The RR, PR, R-R interval and rhythm were obtained simultaneously from the right carotid artery area in a supine position and under normal breathing conditions using IR-UWB radar. There was excellent agreement between the RR obtained by IR-UWB radar and that manually counted by a physician (intraclass correlation coefficient [ICC] 0.852). In the NSR group, there was excellent agreement between the PR (ICC 0.985), average R-R interval (ICC 0.999), and individual R-R interval (ICC 0.910) measured by IR-UWB radar and electrocardiography. In the PeAF group, PR (ICC 0.930), average R-R interval (ICC 0.957) and individual R-R interval (ICC 0.701) also agreed well between the two methods. These results demonstrate that IR-UWB radar can simultaneously monitor respiration, carotid pulse and heart rhythm with high precision and may thus be utilized as a noncontact continuous vital sign monitoring in clinical practice. Nature Publishing Group UK 2019-08-15 /pmc/articles/PMC6695386/ /pubmed/31417149 http://dx.doi.org/10.1038/s41598-019-48386-9 Text en © The Author(s) 2019 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Article
Park, Jun-Young
Lee, Yonggu
Choi, Yeon-Woo
Heo, Ran
Park, Hyun-Kyung
Cho, Seok-Hyun
Cho, Sung Ho
Lim, Young-Hyo
Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title_full Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title_fullStr Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title_full_unstemmed Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title_short Preclinical Evaluation of a Noncontact Simultaneous Monitoring Method for Respiration and Carotid Pulsation Using Impulse-Radio Ultra-Wideband Radar
title_sort preclinical evaluation of a noncontact simultaneous monitoring method for respiration and carotid pulsation using impulse-radio ultra-wideband radar
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695386/
https://www.ncbi.nlm.nih.gov/pubmed/31417149
http://dx.doi.org/10.1038/s41598-019-48386-9
work_keys_str_mv AT parkjunyoung preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT leeyonggu preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT choiyeonwoo preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT heoran preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT parkhyunkyung preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT choseokhyun preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT chosungho preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar
AT limyounghyo preclinicalevaluationofanoncontactsimultaneousmonitoringmethodforrespirationandcarotidpulsationusingimpulseradioultrawidebandradar