Cargando…

Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation

BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method f...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Jia-Xing, Cai, Ai-Lu, Xie, Li-Mei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Baishideng Publishing Group Inc 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695553/
https://www.ncbi.nlm.nih.gov/pubmed/31423432
http://dx.doi.org/10.12998/wjcc.v7.i15.2003
_version_ 1783444064413155328
author Sun, Jia-Xing
Cai, Ai-Lu
Xie, Li-Mei
author_facet Sun, Jia-Xing
Cai, Ai-Lu
Xie, Li-Mei
author_sort Sun, Jia-Xing
collection PubMed
description BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function. AIM: To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses. METHODS: Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated. RESULTS: Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35(+6) wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35(+6) wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35(+6) wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35(+6) wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05). CONCLUSION: Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function.
format Online
Article
Text
id pubmed-6695553
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Baishideng Publishing Group Inc
record_format MEDLINE/PubMed
spelling pubmed-66955532019-08-16 Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation Sun, Jia-Xing Cai, Ai-Lu Xie, Li-Mei World J Clin Cases Observational Study BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function. AIM: To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses. METHODS: Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated. RESULTS: Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35(+6) wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35(+6) wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35(+6) wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35(+6) wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05). CONCLUSION: Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function. Baishideng Publishing Group Inc 2019-08-06 2019-08-06 /pmc/articles/PMC6695553/ /pubmed/31423432 http://dx.doi.org/10.12998/wjcc.v7.i15.2003 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial.
spellingShingle Observational Study
Sun, Jia-Xing
Cai, Ai-Lu
Xie, Li-Mei
Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title_full Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title_fullStr Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title_full_unstemmed Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title_short Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
title_sort evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
topic Observational Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695553/
https://www.ncbi.nlm.nih.gov/pubmed/31423432
http://dx.doi.org/10.12998/wjcc.v7.i15.2003
work_keys_str_mv AT sunjiaxing evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation
AT caiailu evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation
AT xielimei evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation