Cargando…
Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation
BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method f...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695553/ https://www.ncbi.nlm.nih.gov/pubmed/31423432 http://dx.doi.org/10.12998/wjcc.v7.i15.2003 |
_version_ | 1783444064413155328 |
---|---|
author | Sun, Jia-Xing Cai, Ai-Lu Xie, Li-Mei |
author_facet | Sun, Jia-Xing Cai, Ai-Lu Xie, Li-Mei |
author_sort | Sun, Jia-Xing |
collection | PubMed |
description | BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function. AIM: To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses. METHODS: Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated. RESULTS: Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35(+6) wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35(+6) wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35(+6) wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35(+6) wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05). CONCLUSION: Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function. |
format | Online Article Text |
id | pubmed-6695553 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-66955532019-08-16 Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation Sun, Jia-Xing Cai, Ai-Lu Xie, Li-Mei World J Clin Cases Observational Study BACKGROUND: Heart defects are the most common congenital malformations in fetuses. Fetal cardiac structure and function abnormalities lead to changes in ventricular volume. As ventricular volume is an important index for evaluating fetal cardiovascular development, an effective and reliable method for measuring fetal ventricular volume and cardiac function is necessary for accurate ultrasonic diagnosis and effective clinical treatment. The new intelligent spatiotemporal image correlation (iSTIC) technology acquires high-resolution volumetric images. In this study, the iSTIC technique was used to measure right ventricular volume and to evaluate right ventricular systolic function to provide a more accurate and convenient evaluation of fetal heart function. AIM: To investigate the value of iSTIC in evaluating right ventricular volume and systolic function in normal fetuses. METHODS: Between October 2014 and September 2015, a total of 123 pregnant women received prenatal ultrasound examinations in our hospital. iSTIC technology was used to acquire the entire fetal cardiac volume with off-line analysis using QLAB software. Cardiac systolic and diastolic phases were defined by opening of the atrioventricular valve and the subsequent closure of the atrioventricular valve. The volumetric data of the two phases were measured by manual tracking and summation of multiple slices and recording of the right ventricular end-systolic volume and the right ventricular end-diastolic volume. The data were used to calculate the right stroke volume, the right cardiac output, and the right ejection fraction. The correlations of changes between the above-mentioned indices and gestational age were analyzed. The right ventricular volumes of 30 randomly selected cases were measured twice by the same sonographer, and the intra-observer agreement measurements were calculated. RESULTS: Among the 123 normal fetuses, the mean right ventricular end-diastolic volume increased from 0.99 ± 0.34 mL at 22 wk gestation to 3.69 ± 0.36 mL at 35(+6) wk gestation. The mean right ventricular end-systolic volume increased from 0.43 ± 0.18 mL at 22 wk gestation to 1.36 ± 0.22 mL at 35(+6) wk gestation. The mean right stroke volume increased from 0.62 ± 0.29 mL at 22 wk gestation to 2.33 ± 0.18 mL at 35(+6) wk gestation. The mean right cardiac output increased from 92.23 ± 40.67 mL/min at 22 wk gestation to 335.83 ± 32.75 mL/min at 35(+6) wk gestation. Right ventricular end-diastolic volume, right ventricular end-systolic volume, right stroke volume, and right cardiac output all increased with gestational age and the correlations were linear (P < 0.01). Right ejection fraction had no apparent correlation with gestational age (P > 0.05). CONCLUSION: Fetal right ventricular volume can be quantitatively measured using iSTIC technology with relative ease and high repeatability. iSTIC technology is expected to provide a new method for clinical evaluation of fetal cardiac function. Baishideng Publishing Group Inc 2019-08-06 2019-08-06 /pmc/articles/PMC6695553/ /pubmed/31423432 http://dx.doi.org/10.12998/wjcc.v7.i15.2003 Text en ©The Author(s) 2019. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Observational Study Sun, Jia-Xing Cai, Ai-Lu Xie, Li-Mei Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title | Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title_full | Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title_fullStr | Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title_full_unstemmed | Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title_short | Evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
title_sort | evaluation of right ventricular volume and systolic function in normal fetuses using intelligent spatiotemporal image correlation |
topic | Observational Study |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695553/ https://www.ncbi.nlm.nih.gov/pubmed/31423432 http://dx.doi.org/10.12998/wjcc.v7.i15.2003 |
work_keys_str_mv | AT sunjiaxing evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation AT caiailu evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation AT xielimei evaluationofrightventricularvolumeandsystolicfunctioninnormalfetusesusingintelligentspatiotemporalimagecorrelation |