Cargando…
A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size redu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695633/ https://www.ncbi.nlm.nih.gov/pubmed/31357641 http://dx.doi.org/10.3390/s19153308 |
_version_ | 1783444081032036352 |
---|---|
author | Wei, Zhihua Huang, Jie Li, Jing Li, Junshan Liu, Xuyang Ni, Xingsheng |
author_facet | Wei, Zhihua Huang, Jie Li, Jing Li, Junshan Liu, Xuyang Ni, Xingsheng |
author_sort | Wei, Zhihua |
collection | PubMed |
description | In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size reduction (up to 85.9%) in comparison with a conventional TM(010)-mode circular SIW cavity. The operating principle of the humidity sensor is based on the resonant method, in other words, it utilizes the resonant properties of the sensor as signatures to detect the humidity condition of the ambient environment. To this end, a mathematical model quantitatively relating the resonant frequency of the sensor and the relative humidity (RH) level was established according to the cavity perturbation theory. The sensing performance of the sensor was experimentally validated in a RH range of 30%–80% by using a humidity chamber. The measured absolute sensitivity of the sensor was calculated to be 135.6 kHz/%RH, and the corresponding normalized sensitivity was 0.00627%/%RH. It was demonstrated that our proposed sensor not only has the merits of compact size and high sensitivity, but also benefits from a high Q-factor and ease of fabrication and integration. These advantages make it an excellent candidate for humidity sensing applications in various fields such as the agricultural, pharmaceutical, and food industries. |
format | Online Article Text |
id | pubmed-6695633 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-66956332019-09-05 A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing Wei, Zhihua Huang, Jie Li, Jing Li, Junshan Liu, Xuyang Ni, Xingsheng Sensors (Basel) Article In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size reduction (up to 85.9%) in comparison with a conventional TM(010)-mode circular SIW cavity. The operating principle of the humidity sensor is based on the resonant method, in other words, it utilizes the resonant properties of the sensor as signatures to detect the humidity condition of the ambient environment. To this end, a mathematical model quantitatively relating the resonant frequency of the sensor and the relative humidity (RH) level was established according to the cavity perturbation theory. The sensing performance of the sensor was experimentally validated in a RH range of 30%–80% by using a humidity chamber. The measured absolute sensitivity of the sensor was calculated to be 135.6 kHz/%RH, and the corresponding normalized sensitivity was 0.00627%/%RH. It was demonstrated that our proposed sensor not only has the merits of compact size and high sensitivity, but also benefits from a high Q-factor and ease of fabrication and integration. These advantages make it an excellent candidate for humidity sensing applications in various fields such as the agricultural, pharmaceutical, and food industries. MDPI 2019-07-27 /pmc/articles/PMC6695633/ /pubmed/31357641 http://dx.doi.org/10.3390/s19153308 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wei, Zhihua Huang, Jie Li, Jing Li, Junshan Liu, Xuyang Ni, Xingsheng A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title | A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title_full | A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title_fullStr | A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title_full_unstemmed | A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title_short | A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing |
title_sort | compact double-folded substrate integrated waveguide re-entrant cavity for highly sensitive humidity sensing |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695633/ https://www.ncbi.nlm.nih.gov/pubmed/31357641 http://dx.doi.org/10.3390/s19153308 |
work_keys_str_mv | AT weizhihua acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT huangjie acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT lijing acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT lijunshan acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT liuxuyang acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT nixingsheng acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT weizhihua compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT huangjie compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT lijing compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT lijunshan compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT liuxuyang compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing AT nixingsheng compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing |