Cargando…

A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing

In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size redu...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Zhihua, Huang, Jie, Li, Jing, Li, Junshan, Liu, Xuyang, Ni, Xingsheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695633/
https://www.ncbi.nlm.nih.gov/pubmed/31357641
http://dx.doi.org/10.3390/s19153308
_version_ 1783444081032036352
author Wei, Zhihua
Huang, Jie
Li, Jing
Li, Junshan
Liu, Xuyang
Ni, Xingsheng
author_facet Wei, Zhihua
Huang, Jie
Li, Jing
Li, Junshan
Liu, Xuyang
Ni, Xingsheng
author_sort Wei, Zhihua
collection PubMed
description In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size reduction (up to 85.9%) in comparison with a conventional TM(010)-mode circular SIW cavity. The operating principle of the humidity sensor is based on the resonant method, in other words, it utilizes the resonant properties of the sensor as signatures to detect the humidity condition of the ambient environment. To this end, a mathematical model quantitatively relating the resonant frequency of the sensor and the relative humidity (RH) level was established according to the cavity perturbation theory. The sensing performance of the sensor was experimentally validated in a RH range of 30%–80% by using a humidity chamber. The measured absolute sensitivity of the sensor was calculated to be 135.6 kHz/%RH, and the corresponding normalized sensitivity was 0.00627%/%RH. It was demonstrated that our proposed sensor not only has the merits of compact size and high sensitivity, but also benefits from a high Q-factor and ease of fabrication and integration. These advantages make it an excellent candidate for humidity sensing applications in various fields such as the agricultural, pharmaceutical, and food industries.
format Online
Article
Text
id pubmed-6695633
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66956332019-09-05 A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing Wei, Zhihua Huang, Jie Li, Jing Li, Junshan Liu, Xuyang Ni, Xingsheng Sensors (Basel) Article In this study, an ultra-compact humidity sensor based on a double-folded substrate integrated waveguide (SIW) re-entrant cavity was proposed and analyzed. By folding a circular re-entrant cavity twice along its two orthogonally symmetric planes, the designed structure achieved a remarkable size reduction (up to 85.9%) in comparison with a conventional TM(010)-mode circular SIW cavity. The operating principle of the humidity sensor is based on the resonant method, in other words, it utilizes the resonant properties of the sensor as signatures to detect the humidity condition of the ambient environment. To this end, a mathematical model quantitatively relating the resonant frequency of the sensor and the relative humidity (RH) level was established according to the cavity perturbation theory. The sensing performance of the sensor was experimentally validated in a RH range of 30%–80% by using a humidity chamber. The measured absolute sensitivity of the sensor was calculated to be 135.6 kHz/%RH, and the corresponding normalized sensitivity was 0.00627%/%RH. It was demonstrated that our proposed sensor not only has the merits of compact size and high sensitivity, but also benefits from a high Q-factor and ease of fabrication and integration. These advantages make it an excellent candidate for humidity sensing applications in various fields such as the agricultural, pharmaceutical, and food industries. MDPI 2019-07-27 /pmc/articles/PMC6695633/ /pubmed/31357641 http://dx.doi.org/10.3390/s19153308 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wei, Zhihua
Huang, Jie
Li, Jing
Li, Junshan
Liu, Xuyang
Ni, Xingsheng
A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title_full A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title_fullStr A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title_full_unstemmed A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title_short A Compact Double-Folded Substrate Integrated Waveguide Re-Entrant Cavity for Highly Sensitive Humidity Sensing
title_sort compact double-folded substrate integrated waveguide re-entrant cavity for highly sensitive humidity sensing
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695633/
https://www.ncbi.nlm.nih.gov/pubmed/31357641
http://dx.doi.org/10.3390/s19153308
work_keys_str_mv AT weizhihua acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT huangjie acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT lijing acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT lijunshan acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT liuxuyang acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT nixingsheng acompactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT weizhihua compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT huangjie compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT lijing compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT lijunshan compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT liuxuyang compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing
AT nixingsheng compactdoublefoldedsubstrateintegratedwaveguidereentrantcavityforhighlysensitivehumiditysensing