Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device

The classifier of support vector machine (SVM) learning for assessing the quality of arteriovenous fistulae (AVFs) in hemodialysis (HD) patients using a new photoplethysmography (PPG) sensor device is presented in this work. In clinical practice, there are two important indices for assessing the qua...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiang, Pei-Yu, Chao, Paul C. -P., Tu, Tse-Yi, Kao, Yung-Hua, Yang, Chih-Yu, Tarng, Der-Cherng, Wey, Chin-Long
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695851/
https://www.ncbi.nlm.nih.gov/pubmed/31382707
http://dx.doi.org/10.3390/s19153422
_version_ 1783444132115513344
author Chiang, Pei-Yu
Chao, Paul C. -P.
Tu, Tse-Yi
Kao, Yung-Hua
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
author_facet Chiang, Pei-Yu
Chao, Paul C. -P.
Tu, Tse-Yi
Kao, Yung-Hua
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
author_sort Chiang, Pei-Yu
collection PubMed
description The classifier of support vector machine (SVM) learning for assessing the quality of arteriovenous fistulae (AVFs) in hemodialysis (HD) patients using a new photoplethysmography (PPG) sensor device is presented in this work. In clinical practice, there are two important indices for assessing the quality of AVF: the blood flow volume (BFV) and the degree of stenosis (DOS). In hospitals, the BFV and DOS of AVFs are nowadays assessed using an ultrasound Doppler machine, which is bulky, expensive, hard to use, and time consuming. In this study, a newly-developed PPG sensor device was utilized to provide patients and doctors with an inexpensive and small-sized solution for ubiquitous AVF assessment. The readout in this sensor was custom-designed to increase the signal-to-noise ratio (SNR) and reduce the environment interference via maximizing successfully the full dynamic range of measured PPG entering an analog–digital converter (ADC) and effective filtering techniques. With quality PPG measurements obtained, machine learning classifiers including SVM were adopted to assess AVF quality, where the input features are determined based on optical Beer–Lambert’s law and hemodynamic model, to ensure all the necessary features are considered. Finally, the clinical experiment results showed that the proposed PPG sensor device successfully achieved an accuracy of 87.84% based on SVM analysis in assessing DOS at AVF, while an accuracy of 88.61% was achieved for assessing BFV at AVF.
format Online
Article
Text
id pubmed-6695851
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66958512019-09-05 Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device Chiang, Pei-Yu Chao, Paul C. -P. Tu, Tse-Yi Kao, Yung-Hua Yang, Chih-Yu Tarng, Der-Cherng Wey, Chin-Long Sensors (Basel) Article The classifier of support vector machine (SVM) learning for assessing the quality of arteriovenous fistulae (AVFs) in hemodialysis (HD) patients using a new photoplethysmography (PPG) sensor device is presented in this work. In clinical practice, there are two important indices for assessing the quality of AVF: the blood flow volume (BFV) and the degree of stenosis (DOS). In hospitals, the BFV and DOS of AVFs are nowadays assessed using an ultrasound Doppler machine, which is bulky, expensive, hard to use, and time consuming. In this study, a newly-developed PPG sensor device was utilized to provide patients and doctors with an inexpensive and small-sized solution for ubiquitous AVF assessment. The readout in this sensor was custom-designed to increase the signal-to-noise ratio (SNR) and reduce the environment interference via maximizing successfully the full dynamic range of measured PPG entering an analog–digital converter (ADC) and effective filtering techniques. With quality PPG measurements obtained, machine learning classifiers including SVM were adopted to assess AVF quality, where the input features are determined based on optical Beer–Lambert’s law and hemodynamic model, to ensure all the necessary features are considered. Finally, the clinical experiment results showed that the proposed PPG sensor device successfully achieved an accuracy of 87.84% based on SVM analysis in assessing DOS at AVF, while an accuracy of 88.61% was achieved for assessing BFV at AVF. MDPI 2019-08-04 /pmc/articles/PMC6695851/ /pubmed/31382707 http://dx.doi.org/10.3390/s19153422 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chiang, Pei-Yu
Chao, Paul C. -P.
Tu, Tse-Yi
Kao, Yung-Hua
Yang, Chih-Yu
Tarng, Der-Cherng
Wey, Chin-Long
Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title_full Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title_fullStr Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title_full_unstemmed Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title_short Machine Learning Classification for Assessing the Degree of Stenosis and Blood Flow Volume at Arteriovenous Fistulas of Hemodialysis Patients Using a New Photoplethysmography Sensor Device
title_sort machine learning classification for assessing the degree of stenosis and blood flow volume at arteriovenous fistulas of hemodialysis patients using a new photoplethysmography sensor device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6695851/
https://www.ncbi.nlm.nih.gov/pubmed/31382707
http://dx.doi.org/10.3390/s19153422
work_keys_str_mv AT chiangpeiyu machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT chaopaulcp machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT tutseyi machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT kaoyunghua machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT yangchihyu machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT tarngdercherng machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice
AT weychinlong machinelearningclassificationforassessingthedegreeofstenosisandbloodflowvolumeatarteriovenousfistulasofhemodialysispatientsusinganewphotoplethysmographysensordevice