Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results

The study continues the theoretical derivation from Part 1, and the experiment is carried out at a bus station equipped with six water-cooled chillers. Between 2012 and 2017, historical data collected from temperature and humidity sensors, as well as the energy consumption data, were used to build a...

Descripción completa

Detalles Bibliográficos
Autores principales: Cheng, Chin-Chi, Lee, Dasheng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6696414/
https://www.ncbi.nlm.nih.gov/pubmed/31390776
http://dx.doi.org/10.3390/s19153440
_version_ 1783444264895643648
author Cheng, Chin-Chi
Lee, Dasheng
author_facet Cheng, Chin-Chi
Lee, Dasheng
author_sort Cheng, Chin-Chi
collection PubMed
description The study continues the theoretical derivation from Part 1, and the experiment is carried out at a bus station equipped with six water-cooled chillers. Between 2012 and 2017, historical data collected from temperature and humidity sensors, as well as the energy consumption data, were used to build artificial intelligence (AI) assisted heating ventilation and air conditioning (HVAC) control models. The AI control system, in conjunction with a specifically designed prior information notice (PIN) sensor, was used to improve the prediction accuracy. This data collected between 2012 and 2016 was used for AI training and PIN sensor testing. During the hottest week of 2017 in Taiwan, the PIN sensor was used to conduct temperature and humidity data predictions. A model-based predictive control was developed to obtain air conditioning energy consumption data. The comparative results between the predictive and actual data showed that the temperature and humidity prediction accuracies were between 95.5 and 96.6%, respectively. Additionally, energy savings amounting to 39.8% were achieved compared to the theoretical estimates of 44.6%, a difference of less than 5%. These results show that the experimental model supports the theoretical estimations. In the future, a PIN sensor will be installed in a chiller to further verify the energy savings of the AI assisted HVAC control.
format Online
Article
Text
id pubmed-6696414
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66964142019-09-05 Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results Cheng, Chin-Chi Lee, Dasheng Sensors (Basel) Article The study continues the theoretical derivation from Part 1, and the experiment is carried out at a bus station equipped with six water-cooled chillers. Between 2012 and 2017, historical data collected from temperature and humidity sensors, as well as the energy consumption data, were used to build artificial intelligence (AI) assisted heating ventilation and air conditioning (HVAC) control models. The AI control system, in conjunction with a specifically designed prior information notice (PIN) sensor, was used to improve the prediction accuracy. This data collected between 2012 and 2016 was used for AI training and PIN sensor testing. During the hottest week of 2017 in Taiwan, the PIN sensor was used to conduct temperature and humidity data predictions. A model-based predictive control was developed to obtain air conditioning energy consumption data. The comparative results between the predictive and actual data showed that the temperature and humidity prediction accuracies were between 95.5 and 96.6%, respectively. Additionally, energy savings amounting to 39.8% were achieved compared to the theoretical estimates of 44.6%, a difference of less than 5%. These results show that the experimental model supports the theoretical estimations. In the future, a PIN sensor will be installed in a chiller to further verify the energy savings of the AI assisted HVAC control. MDPI 2019-08-06 /pmc/articles/PMC6696414/ /pubmed/31390776 http://dx.doi.org/10.3390/s19153440 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cheng, Chin-Chi
Lee, Dasheng
Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title_full Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title_fullStr Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title_full_unstemmed Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title_short Artificial Intelligence Assisted Heating Ventilation and Air Conditioning Control and the Unmet Demand for Sensors: Part 2. Prior Information Notice (PIN) Sensor Design and Simulation Results
title_sort artificial intelligence assisted heating ventilation and air conditioning control and the unmet demand for sensors: part 2. prior information notice (pin) sensor design and simulation results
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6696414/
https://www.ncbi.nlm.nih.gov/pubmed/31390776
http://dx.doi.org/10.3390/s19153440
work_keys_str_mv AT chengchinchi artificialintelligenceassistedheatingventilationandairconditioningcontrolandtheunmetdemandforsensorspart2priorinformationnoticepinsensordesignandsimulationresults