Cargando…

Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering

With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Min, Li, Zhe, Zhang, Qirui, Wang, Guoxing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6696451/
https://www.ncbi.nlm.nih.gov/pubmed/31357674
http://dx.doi.org/10.3390/s19153312
_version_ 1783444273391206400
author Wang, Min
Li, Zhe
Zhang, Qirui
Wang, Guoxing
author_facet Wang, Min
Li, Zhe
Zhang, Qirui
Wang, Guoxing
author_sort Wang, Min
collection PubMed
description With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise.
format Online
Article
Text
id pubmed-6696451
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-66964512019-09-05 Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering Wang, Min Li, Zhe Zhang, Qirui Wang, Guoxing Sensors (Basel) Article With photoplethysmograph (PPG) sensors showing increasing potential in wearable health monitoring, the challenging problem of motion artifact (MA) removal during intensive exercise has become a popular research topic. In this study, a novel method that combines heart rate frequency (HRF) estimation and notch filtering is proposed. The proposed method applies a cascaded adaptive noise cancellation (ANC) based on the least mean squares (LMS)-Newton algorithm for preliminary motion artifacts reduction, and further adopts special heart rate frequency tracking and correction schemes for accurate HRF estimation. Finally, notch filters are employed to restore the PPG signal with estimated HRF based on its quasi-periodicity. On an open source data set that features intensive running exercise, the proposed method achieves a competitive mean average absolute error (AAE) result of 0.92 bpm for HR estimation. The practical experiments are carried out with the PPG evaluation platform developed by ourselves. Under three different intensive motion patterns, a 0.89 bpm average AAE result is achieved with the average correlation coefficient between recovered PPG signal and reference PPG signal reaching 0.86. The experimental results demonstrate the effectiveness of the proposed method for accurate HR estimation and robust MA removal in PPG during intensive exercise. MDPI 2019-07-28 /pmc/articles/PMC6696451/ /pubmed/31357674 http://dx.doi.org/10.3390/s19153312 Text en © 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Min
Li, Zhe
Zhang, Qirui
Wang, Guoxing
Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title_full Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title_fullStr Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title_full_unstemmed Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title_short Removal of Motion Artifacts in Photoplethysmograph Sensors during Intensive Exercise for Accurate Heart Rate Calculation Based on Frequency Estimation and Notch Filtering
title_sort removal of motion artifacts in photoplethysmograph sensors during intensive exercise for accurate heart rate calculation based on frequency estimation and notch filtering
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6696451/
https://www.ncbi.nlm.nih.gov/pubmed/31357674
http://dx.doi.org/10.3390/s19153312
work_keys_str_mv AT wangmin removalofmotionartifactsinphotoplethysmographsensorsduringintensiveexerciseforaccurateheartratecalculationbasedonfrequencyestimationandnotchfiltering
AT lizhe removalofmotionartifactsinphotoplethysmographsensorsduringintensiveexerciseforaccurateheartratecalculationbasedonfrequencyestimationandnotchfiltering
AT zhangqirui removalofmotionartifactsinphotoplethysmographsensorsduringintensiveexerciseforaccurateheartratecalculationbasedonfrequencyestimationandnotchfiltering
AT wangguoxing removalofmotionartifactsinphotoplethysmographsensorsduringintensiveexerciseforaccurateheartratecalculationbasedonfrequencyestimationandnotchfiltering