Cargando…
Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures
BACKGROUND: Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fra...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698331/ https://www.ncbi.nlm.nih.gov/pubmed/31421675 http://dx.doi.org/10.1186/s12891-019-2757-z |
_version_ | 1783444531442614272 |
---|---|
author | Jeong, Jae-Jung Park, Sang-Eun Lee, Hwan-Hee Ji, Jong-Hun Park, Min-Sik Park, Yong-Taek |
author_facet | Jeong, Jae-Jung Park, Sang-Eun Lee, Hwan-Hee Ji, Jong-Hun Park, Min-Sik Park, Yong-Taek |
author_sort | Jeong, Jae-Jung |
collection | PubMed |
description | BACKGROUND: Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fracture extension. METHODS: From January 2009 to May 2016, we retrospectively studied 35 patients who underwent MIPO for spiral humerus shaft fractures with or without metaphyseal fracture extension (AO classification 12 A, B, C except A3). Eighteen patients underwent MIPO with a 4.5 mm NLCP (group I) in the early period of this study, while 17 patients underwent MIPO with LPP (group II) in the later period. Range of motion (ROM), pre- and post-operative anteroposterior (AP) and lateral angulation of the fracture, operation time, amount of bleeding, and functional outcomes including American Shoulder and Elbow Surgeons score, University of California at Los Angeles score, and Simple Shoulder Test score were analyzed at the final follow up. RESULTS: All patients had complete bony union and achieved satisfactory functional outcomes except 2 patients. In LPP group, better outcomes in postoperative fracture angulation on X-ray and operation time (p < 0.05) were shown. But, two revision surgery with NLCP and bone graft was performed owing to 2 metal failures. CONCLUSIONS: In spiral humeral shaft fractures, LPP group showed better fracture reduction on X-ray and shorter operation time except metal failure owing to weak fixation. Even though MIPO technique using LPP is easier and more accurate reduction method, rigid fixation should be considered. |
format | Online Article Text |
id | pubmed-6698331 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-66983312019-08-22 Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures Jeong, Jae-Jung Park, Sang-Eun Lee, Hwan-Hee Ji, Jong-Hun Park, Min-Sik Park, Yong-Taek BMC Musculoskelet Disord Research Article BACKGROUND: Our hypothesis was that minimally invasive plate osteosynthesis (MIPO) using long philos plate (LPP) would show better clinical and radiological outcomes and less complications than narrow locking compression plate (NLCP) for spiral humerus shaft fractures with or without metaphyseal fracture extension. METHODS: From January 2009 to May 2016, we retrospectively studied 35 patients who underwent MIPO for spiral humerus shaft fractures with or without metaphyseal fracture extension (AO classification 12 A, B, C except A3). Eighteen patients underwent MIPO with a 4.5 mm NLCP (group I) in the early period of this study, while 17 patients underwent MIPO with LPP (group II) in the later period. Range of motion (ROM), pre- and post-operative anteroposterior (AP) and lateral angulation of the fracture, operation time, amount of bleeding, and functional outcomes including American Shoulder and Elbow Surgeons score, University of California at Los Angeles score, and Simple Shoulder Test score were analyzed at the final follow up. RESULTS: All patients had complete bony union and achieved satisfactory functional outcomes except 2 patients. In LPP group, better outcomes in postoperative fracture angulation on X-ray and operation time (p < 0.05) were shown. But, two revision surgery with NLCP and bone graft was performed owing to 2 metal failures. CONCLUSIONS: In spiral humeral shaft fractures, LPP group showed better fracture reduction on X-ray and shorter operation time except metal failure owing to weak fixation. Even though MIPO technique using LPP is easier and more accurate reduction method, rigid fixation should be considered. BioMed Central 2019-08-17 /pmc/articles/PMC6698331/ /pubmed/31421675 http://dx.doi.org/10.1186/s12891-019-2757-z Text en © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Jeong, Jae-Jung Park, Sang-Eun Lee, Hwan-Hee Ji, Jong-Hun Park, Min-Sik Park, Yong-Taek Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title | Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title_full | Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title_fullStr | Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title_full_unstemmed | Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title_short | Narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
title_sort | narrow locking compression plate vs long philos plate for minimally invasive plate osteosynthesis of spiral humerus shaft fractures |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698331/ https://www.ncbi.nlm.nih.gov/pubmed/31421675 http://dx.doi.org/10.1186/s12891-019-2757-z |
work_keys_str_mv | AT jeongjaejung narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures AT parksangeun narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures AT leehwanhee narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures AT jijonghun narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures AT parkminsik narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures AT parkyongtaek narrowlockingcompressionplatevslongphilosplateforminimallyinvasiveplateosteosynthesisofspiralhumerusshaftfractures |