Cargando…
A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays
The threshold between low and medium antibody levels for anticardiolipin (aCL) and anti-β2 glycoprotein I antibodies (aβ2GPI) for the diagnosis of antiphospholipid syndrome (APS) remains a matter of discussion. Our goal was to create a protocol for determining the low/medium antibody cut-off for aCL...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698831/ https://www.ncbi.nlm.nih.gov/pubmed/31557995 http://dx.doi.org/10.3390/antib5020014 |
_version_ | 1783444623402729472 |
---|---|
author | Lakos, Gabriella Bentow, Chelsea Mahler, Michael |
author_facet | Lakos, Gabriella Bentow, Chelsea Mahler, Michael |
author_sort | Lakos, Gabriella |
collection | PubMed |
description | The threshold between low and medium antibody levels for anticardiolipin (aCL) and anti-β2 glycoprotein I antibodies (aβ2GPI) for the diagnosis of antiphospholipid syndrome (APS) remains a matter of discussion. Our goal was to create a protocol for determining the low/medium antibody cut-off for aCL antibody methods based on a clinical approach, and utilize it to establish the clinically-relevant low/medium threshold for QUANTA Flash aCL chemiluminescent immunoassay (CIA) results. The study included 288 samples from patients with primary APS (n = 70), secondary APS (n = 42), suspected APS (n = 36), systemic lupus erythematosus (SLE) without APS (n = 96) and other connective tissue diseases (n = 44). All samples were tested for IgG and IgM aCL antibodies with QUANTA Flash CIA, along with traditional enzyme-linked immunosorbent assays (ELISAs) (QUANTA Lite). The assay specific low/medium threshold for QUANTA Flash aCL IgG and IgM assays (i.e., the equivalent of 40 GPL and MPL units) was established as 95 and 31 chemiluminescent units (CU), respectively, based on clinical performance and comparison to QUANTA Lite ELISAs. Agreement between CIA and ELISA assay results improved substantially when the platform-specific low/medium antibody threshold was used, as compared to agreement obtained on results generated with the assay cutoff: Cohen’s kappa increased from 0.85 to 0.91 for IgG aCL, and from 0.59 to 0.75 for IgM aCL results. This study describes a clinical approach for establishing the low/medium antibody threshold for aPL antibody assays, and successfully employs it to define 95 and 31 CU, respectively, as the low/medium cut point for QUANTA Flash aCL IgG and IgM results. This study can serve as a model for labs wishing to establish the appropriate low/medium aPL antibody threshold when implementing new aPL antibody assays. |
format | Online Article Text |
id | pubmed-6698831 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-66988312019-09-05 A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays Lakos, Gabriella Bentow, Chelsea Mahler, Michael Antibodies (Basel) Article The threshold between low and medium antibody levels for anticardiolipin (aCL) and anti-β2 glycoprotein I antibodies (aβ2GPI) for the diagnosis of antiphospholipid syndrome (APS) remains a matter of discussion. Our goal was to create a protocol for determining the low/medium antibody cut-off for aCL antibody methods based on a clinical approach, and utilize it to establish the clinically-relevant low/medium threshold for QUANTA Flash aCL chemiluminescent immunoassay (CIA) results. The study included 288 samples from patients with primary APS (n = 70), secondary APS (n = 42), suspected APS (n = 36), systemic lupus erythematosus (SLE) without APS (n = 96) and other connective tissue diseases (n = 44). All samples were tested for IgG and IgM aCL antibodies with QUANTA Flash CIA, along with traditional enzyme-linked immunosorbent assays (ELISAs) (QUANTA Lite). The assay specific low/medium threshold for QUANTA Flash aCL IgG and IgM assays (i.e., the equivalent of 40 GPL and MPL units) was established as 95 and 31 chemiluminescent units (CU), respectively, based on clinical performance and comparison to QUANTA Lite ELISAs. Agreement between CIA and ELISA assay results improved substantially when the platform-specific low/medium antibody threshold was used, as compared to agreement obtained on results generated with the assay cutoff: Cohen’s kappa increased from 0.85 to 0.91 for IgG aCL, and from 0.59 to 0.75 for IgM aCL results. This study describes a clinical approach for establishing the low/medium antibody threshold for aPL antibody assays, and successfully employs it to define 95 and 31 CU, respectively, as the low/medium cut point for QUANTA Flash aCL IgG and IgM results. This study can serve as a model for labs wishing to establish the appropriate low/medium aPL antibody threshold when implementing new aPL antibody assays. MDPI 2016-05-25 /pmc/articles/PMC6698831/ /pubmed/31557995 http://dx.doi.org/10.3390/antib5020014 Text en © 2016 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lakos, Gabriella Bentow, Chelsea Mahler, Michael A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title | A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title_full | A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title_fullStr | A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title_full_unstemmed | A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title_short | A Clinical Approach for Defining the Threshold between Low and Medium Anti-Cardiolipin Antibody Levels for QUANTA Flash Assays |
title_sort | clinical approach for defining the threshold between low and medium anti-cardiolipin antibody levels for quanta flash assays |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698831/ https://www.ncbi.nlm.nih.gov/pubmed/31557995 http://dx.doi.org/10.3390/antib5020014 |
work_keys_str_mv | AT lakosgabriella aclinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays AT bentowchelsea aclinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays AT mahlermichael aclinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays AT lakosgabriella clinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays AT bentowchelsea clinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays AT mahlermichael clinicalapproachfordefiningthethresholdbetweenlowandmediumanticardiolipinantibodylevelsforquantaflashassays |