Cargando…

Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum

INTRODUCTION: The aerosol composition of electronic cigarettes (ECs) suggests that exposure to toxicants during use is greatly reduced compared to exposure from combustible cigarettes (CCs). METHODS: This randomized, parallel-group, clinical study enrolled smokers to switch to Vuse Solo (VS) Digital...

Descripción completa

Detalles Bibliográficos
Autores principales: Round, Elaine K, Chen, Peter, Taylor, Anthony K, Schmidt, Eckhardt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698949/
https://www.ncbi.nlm.nih.gov/pubmed/30202883
http://dx.doi.org/10.1093/ntr/nty140
_version_ 1783444639469010944
author Round, Elaine K
Chen, Peter
Taylor, Anthony K
Schmidt, Eckhardt
author_facet Round, Elaine K
Chen, Peter
Taylor, Anthony K
Schmidt, Eckhardt
author_sort Round, Elaine K
collection PubMed
description INTRODUCTION: The aerosol composition of electronic cigarettes (ECs) suggests that exposure to toxicants during use is greatly reduced compared to exposure from combustible cigarettes (CCs). METHODS: This randomized, parallel-group, clinical study enrolled smokers to switch to Vuse Solo (VS) Digital Vapor Cigarettes (Original or Menthol) or Nicorette 4 mg nicotine gum (NG) in a controlled setting. Subjects who smoked CCs ad libitum for 2 days during a baseline period were then randomized to ad libitum use of either VS or NG for 5 days. Biomarkers of 23 toxicants were measured in 24-hour urine samples and blood collected at baseline and following product switch. RESULTS: A total of 153 subjects completed the study. Total nicotine equivalents decreased in all groups, but higher levels were observed in the VS groups compared to the NG groups, with decreases of 38% and 60%–67%, respectively. All other biomarkers were significantly decreased in subjects switched to VS, and the magnitude of biomarker decreases was similar to subjects switched to NG. Decreases ranged from 30% to greater than 85% for constituents such as benzene and acrylonitrile. CONCLUSIONS: These results indicate that exposure to toxicants when using VS is significantly reduced compared to CC smoking, and these reductions are similar to those observed with use of NG. Although statistically significantly decreased, nicotine exposure is maintained closer to CC smoking with VS use compared to NG use. This research suggests that use of VS exposes consumers to fewer and lower levels of smoke toxicants than CCs while still providing nicotine to the consumer. IMPLICATIONS: This is the first study to report changes in nicotine delivery and biomarkers of tobacco exposure following a short-term product switch from CCs to either an EC or NG in a controlled environment. The study shows that nicotine exposure decreased in both groups but was maintained closer to CC smoking with the EC groups. Biomarkers of tobacco combustion decreased to similar levels in both EC and gum groups.
format Online
Article
Text
id pubmed-6698949
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-66989492019-08-22 Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum Round, Elaine K Chen, Peter Taylor, Anthony K Schmidt, Eckhardt Nicotine Tob Res Original Investigations INTRODUCTION: The aerosol composition of electronic cigarettes (ECs) suggests that exposure to toxicants during use is greatly reduced compared to exposure from combustible cigarettes (CCs). METHODS: This randomized, parallel-group, clinical study enrolled smokers to switch to Vuse Solo (VS) Digital Vapor Cigarettes (Original or Menthol) or Nicorette 4 mg nicotine gum (NG) in a controlled setting. Subjects who smoked CCs ad libitum for 2 days during a baseline period were then randomized to ad libitum use of either VS or NG for 5 days. Biomarkers of 23 toxicants were measured in 24-hour urine samples and blood collected at baseline and following product switch. RESULTS: A total of 153 subjects completed the study. Total nicotine equivalents decreased in all groups, but higher levels were observed in the VS groups compared to the NG groups, with decreases of 38% and 60%–67%, respectively. All other biomarkers were significantly decreased in subjects switched to VS, and the magnitude of biomarker decreases was similar to subjects switched to NG. Decreases ranged from 30% to greater than 85% for constituents such as benzene and acrylonitrile. CONCLUSIONS: These results indicate that exposure to toxicants when using VS is significantly reduced compared to CC smoking, and these reductions are similar to those observed with use of NG. Although statistically significantly decreased, nicotine exposure is maintained closer to CC smoking with VS use compared to NG use. This research suggests that use of VS exposes consumers to fewer and lower levels of smoke toxicants than CCs while still providing nicotine to the consumer. IMPLICATIONS: This is the first study to report changes in nicotine delivery and biomarkers of tobacco exposure following a short-term product switch from CCs to either an EC or NG in a controlled environment. The study shows that nicotine exposure decreased in both groups but was maintained closer to CC smoking with the EC groups. Biomarkers of tobacco combustion decreased to similar levels in both EC and gum groups. Oxford University Press 2018-09-10 /pmc/articles/PMC6698949/ /pubmed/30202883 http://dx.doi.org/10.1093/ntr/nty140 Text en © The Author(s) 2018. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Investigations
Round, Elaine K
Chen, Peter
Taylor, Anthony K
Schmidt, Eckhardt
Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title_full Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title_fullStr Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title_full_unstemmed Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title_short Biomarkers of Tobacco Exposure Decrease After Smokers Switch to an E-Cigarette or Nicotine Gum
title_sort biomarkers of tobacco exposure decrease after smokers switch to an e-cigarette or nicotine gum
topic Original Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6698949/
https://www.ncbi.nlm.nih.gov/pubmed/30202883
http://dx.doi.org/10.1093/ntr/nty140
work_keys_str_mv AT roundelainek biomarkersoftobaccoexposuredecreaseaftersmokersswitchtoanecigaretteornicotinegum
AT chenpeter biomarkersoftobaccoexposuredecreaseaftersmokersswitchtoanecigaretteornicotinegum
AT tayloranthonyk biomarkersoftobaccoexposuredecreaseaftersmokersswitchtoanecigaretteornicotinegum
AT schmidteckhardt biomarkersoftobaccoexposuredecreaseaftersmokersswitchtoanecigaretteornicotinegum