Cargando…
Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China
INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheter...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6699060/ https://www.ncbi.nlm.nih.gov/pubmed/30596472 http://dx.doi.org/10.1177/1129729818819732 |
_version_ | 1783444654339915776 |
---|---|
author | Yin, Yu-Xia Gao, Wei Li, Xu-Ying Lu, Wei Deng, Qian-Hong Zhao, Cui-Yun Liu, Xue-Rong Zhou, Chao Hou, Wen-Bo Lu, Shou-Tao Liu, Guang Wang, Lu-Ning Li, Mao-Quan Zhang, Hai-Jun |
author_facet | Yin, Yu-Xia Gao, Wei Li, Xu-Ying Lu, Wei Deng, Qian-Hong Zhao, Cui-Yun Liu, Xue-Rong Zhou, Chao Hou, Wen-Bo Lu, Shou-Tao Liu, Guang Wang, Lu-Ning Li, Mao-Quan Zhang, Hai-Jun |
author_sort | Yin, Yu-Xia |
collection | PubMed |
description | INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. METHODS: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. RESULTS: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%–93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%–81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%–99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%–89.2%) observed in the anatomical landmark group (p < 0.001). CONCLUSION: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks. |
format | Online Article Text |
id | pubmed-6699060 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-66990602019-09-16 Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China Yin, Yu-Xia Gao, Wei Li, Xu-Ying Lu, Wei Deng, Qian-Hong Zhao, Cui-Yun Liu, Xue-Rong Zhou, Chao Hou, Wen-Bo Lu, Shou-Tao Liu, Guang Wang, Lu-Ning Li, Mao-Quan Zhang, Hai-Jun J Vasc Access Original Research Articles INTRODUCTION: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. METHODS: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. RESULTS: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%–93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%–81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%–99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%–89.2%) observed in the anatomical landmark group (p < 0.001). CONCLUSION: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks. SAGE Publications 2018-12-31 2019-09 /pmc/articles/PMC6699060/ /pubmed/30596472 http://dx.doi.org/10.1177/1129729818819732 Text en © The Author(s) 2018 http://www.creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Research Articles Yin, Yu-Xia Gao, Wei Li, Xu-Ying Lu, Wei Deng, Qian-Hong Zhao, Cui-Yun Liu, Xue-Rong Zhou, Chao Hou, Wen-Bo Lu, Shou-Tao Liu, Guang Wang, Lu-Ning Li, Mao-Quan Zhang, Hai-Jun Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China |
title | Insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: A randomized multicenter study in
China |
title_full | Insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: A randomized multicenter study in
China |
title_fullStr | Insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: A randomized multicenter study in
China |
title_full_unstemmed | Insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: A randomized multicenter study in
China |
title_short | Insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: A randomized multicenter study in
China |
title_sort | insertion of peripherally inserted central catheters with
intracavitary electrocardiogram guidance: a randomized multicenter study in
china |
topic | Original Research Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6699060/ https://www.ncbi.nlm.nih.gov/pubmed/30596472 http://dx.doi.org/10.1177/1129729818819732 |
work_keys_str_mv | AT yinyuxia insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT gaowei insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT lixuying insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT luwei insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT dengqianhong insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT zhaocuiyun insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT liuxuerong insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT zhouchao insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT houwenbo insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT lushoutao insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT liuguang insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT wangluning insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT limaoquan insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina AT zhanghaijun insertionofperipherallyinsertedcentralcatheterswithintracavitaryelectrocardiogramguidancearandomizedmulticenterstudyinchina |