Cargando…

Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis

OBJECTIVE: The purpose of this study was to evaluate the impact of different intraocular lens materials (IOL) and optic edge designs on the incidence of Nd:YAG laser capsulotomy. METHODS: Randomized controlled trials (RCTs) reporting incidence of Nd:YAG capsulotomy in patients with monofocal IOLs we...

Descripción completa

Detalles Bibliográficos
Autores principales: Thom, Howard, Ender, Frank, Samavedam, Saisudha, Perez Vivez, Caridad, Gupta, Subhajit, Dhariwal, Mukesh, de Haan, Jan, O’Boyle, Derek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6699683/
https://www.ncbi.nlm.nih.gov/pubmed/31425548
http://dx.doi.org/10.1371/journal.pone.0220498
_version_ 1783444755208732672
author Thom, Howard
Ender, Frank
Samavedam, Saisudha
Perez Vivez, Caridad
Gupta, Subhajit
Dhariwal, Mukesh
de Haan, Jan
O’Boyle, Derek
author_facet Thom, Howard
Ender, Frank
Samavedam, Saisudha
Perez Vivez, Caridad
Gupta, Subhajit
Dhariwal, Mukesh
de Haan, Jan
O’Boyle, Derek
author_sort Thom, Howard
collection PubMed
description OBJECTIVE: The purpose of this study was to evaluate the impact of different intraocular lens materials (IOL) and optic edge designs on the incidence of Nd:YAG laser capsulotomy. METHODS: Randomized controlled trials (RCTs) reporting incidence of Nd:YAG capsulotomy in patients with monofocal IOLs were identified for systematic literature review (SLR) using Cochrane methodology. A network meta-analysis was conducted under a Bayesian framework. Mean hazard ratios (HRs), 95% credible intervals, and one-sided p-values were estimated for Nd:YAG capsulotomy incidence by comparing AcrySof IOLs with a group of non-AcrySof hydrophobic acrylic, hydrophilic acrylic, silicone, and PMMA IOLs. Sensitivity analysis was conducted comparing the risk of Nd:YAG capsulotomy between sharp- and round-edged designs of the above IOLs. RESULTS: AcrySof IOLs had a lower risk of Nd:YAG capsulotomy compared to hydrophobic acrylic (HR: 2.68; 95% CrI: 1.41, 4.77; p < 0.01), hydrophilic acrylic (HR: 7.54; 95% CrI: 4.24, 14.06; p < 0.001), PMMA (HR: 3.64, 95% CrI: 1.87, 6.33; p < 0.001), and silicone (HR: 1.13; 95% CrI: 0.59, 1.91; p <0.1) IOLs. The risk for Nd:YAG was highest among sharp-edged IOLs for hydrophilic acrylic IOLs (HR: 9.32; 95% CrI: 4.32, 19.29; p < 0.01), followed by other hydrophobic acrylic (HR: 2.91; 95% CrI: 1.27, 5.88; p < 0.01), silicone (HR: 0.838; 95% CrI: 0.328, 1.74; p = 0.69), and PMMA (HR: 0.39; 95% CrI: 0.042, 1.49; p = 0.93) IOLs, compared to AcrySof. Acrysof IOLs had a lower risk of Nd:YAG compared to PMMA (HR: 3.25; 95% CrI: 1.21, 7.37; p < 0.01) and silicone, round edge IOLs (HR: 3.84; 95% CrI: 1.08, 10.64; p = 0.015). CONCLUSION: The risk of Nd:YAG capsulotomy is lower in eyes implanted with AcrySof IOLs compared to non-AcrySof hydrophobic or hydrophilic acrylic IOLs. Sharp-edged AcrySof, PMMA, and silicone IOLs are comparable in terms of reducing the risk of Nd:YAG laser capsulotomy.
format Online
Article
Text
id pubmed-6699683
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-66996832019-09-04 Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis Thom, Howard Ender, Frank Samavedam, Saisudha Perez Vivez, Caridad Gupta, Subhajit Dhariwal, Mukesh de Haan, Jan O’Boyle, Derek PLoS One Research Article OBJECTIVE: The purpose of this study was to evaluate the impact of different intraocular lens materials (IOL) and optic edge designs on the incidence of Nd:YAG laser capsulotomy. METHODS: Randomized controlled trials (RCTs) reporting incidence of Nd:YAG capsulotomy in patients with monofocal IOLs were identified for systematic literature review (SLR) using Cochrane methodology. A network meta-analysis was conducted under a Bayesian framework. Mean hazard ratios (HRs), 95% credible intervals, and one-sided p-values were estimated for Nd:YAG capsulotomy incidence by comparing AcrySof IOLs with a group of non-AcrySof hydrophobic acrylic, hydrophilic acrylic, silicone, and PMMA IOLs. Sensitivity analysis was conducted comparing the risk of Nd:YAG capsulotomy between sharp- and round-edged designs of the above IOLs. RESULTS: AcrySof IOLs had a lower risk of Nd:YAG capsulotomy compared to hydrophobic acrylic (HR: 2.68; 95% CrI: 1.41, 4.77; p < 0.01), hydrophilic acrylic (HR: 7.54; 95% CrI: 4.24, 14.06; p < 0.001), PMMA (HR: 3.64, 95% CrI: 1.87, 6.33; p < 0.001), and silicone (HR: 1.13; 95% CrI: 0.59, 1.91; p <0.1) IOLs. The risk for Nd:YAG was highest among sharp-edged IOLs for hydrophilic acrylic IOLs (HR: 9.32; 95% CrI: 4.32, 19.29; p < 0.01), followed by other hydrophobic acrylic (HR: 2.91; 95% CrI: 1.27, 5.88; p < 0.01), silicone (HR: 0.838; 95% CrI: 0.328, 1.74; p = 0.69), and PMMA (HR: 0.39; 95% CrI: 0.042, 1.49; p = 0.93) IOLs, compared to AcrySof. Acrysof IOLs had a lower risk of Nd:YAG compared to PMMA (HR: 3.25; 95% CrI: 1.21, 7.37; p < 0.01) and silicone, round edge IOLs (HR: 3.84; 95% CrI: 1.08, 10.64; p = 0.015). CONCLUSION: The risk of Nd:YAG capsulotomy is lower in eyes implanted with AcrySof IOLs compared to non-AcrySof hydrophobic or hydrophilic acrylic IOLs. Sharp-edged AcrySof, PMMA, and silicone IOLs are comparable in terms of reducing the risk of Nd:YAG laser capsulotomy. Public Library of Science 2019-08-19 /pmc/articles/PMC6699683/ /pubmed/31425548 http://dx.doi.org/10.1371/journal.pone.0220498 Text en © 2019 Thom et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Thom, Howard
Ender, Frank
Samavedam, Saisudha
Perez Vivez, Caridad
Gupta, Subhajit
Dhariwal, Mukesh
de Haan, Jan
O’Boyle, Derek
Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title_full Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title_fullStr Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title_full_unstemmed Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title_short Effect of AcrySof versus other intraocular lens properties on the risk of Nd:YAG capsulotomy after cataract surgery: A systematic literature review and network meta-analysis
title_sort effect of acrysof versus other intraocular lens properties on the risk of nd:yag capsulotomy after cataract surgery: a systematic literature review and network meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6699683/
https://www.ncbi.nlm.nih.gov/pubmed/31425548
http://dx.doi.org/10.1371/journal.pone.0220498
work_keys_str_mv AT thomhoward effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT enderfrank effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT samavedamsaisudha effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT perezvivezcaridad effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT guptasubhajit effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT dhariwalmukesh effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT dehaanjan effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis
AT oboylederek effectofacrysofversusotherintraocularlenspropertiesontheriskofndyagcapsulotomyaftercataractsurgeryasystematicliteraturereviewandnetworkmetaanalysis