As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement...

Descripción completa

Detalles Bibliográficos
Autores principales: Spiezio, Vincent, Walker, Bennett N., Calogero, Don, Ilev, Ilko K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701293/
https://www.ncbi.nlm.nih.gov/pubmed/31467695
http://dx.doi.org/10.1155/2019/7929014
_version_ 1783445024467320832
author Spiezio, Vincent
Walker, Bennett N.
Calogero, Don
Ilev, Ilko K.
author_facet Spiezio, Vincent
Walker, Bennett N.
Calogero, Don
Ilev, Ilko K.
author_sort Spiezio, Vincent
collection PubMed
description As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement. This unwanted scatter is of particular concern for patients viewing bright light in reduced-light conditions such as when driving at night, as the scattered light toward the retina can cause temporary blindness. In this study, we have developed and implemented an accurate test methodology based on a high-magnification digital microscopy approach for quantitative multiparameter evaluation and classification of IOL vacuoles depending on their critical optical characteristics including vacuole size, density, shape, and orientation within the IOL material. Using the multiparameter database developed by evaluating vacuole characteristics, we established a classification grading system that can be used to evaluate vacuole effects on light scattering.
format Online
Article
Text
id pubmed-6701293
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-67012932019-08-29 Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method Spiezio, Vincent Walker, Bennett N. Calogero, Don Ilev, Ilko K. J Ophthalmol Research Article As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement. This unwanted scatter is of particular concern for patients viewing bright light in reduced-light conditions such as when driving at night, as the scattered light toward the retina can cause temporary blindness. In this study, we have developed and implemented an accurate test methodology based on a high-magnification digital microscopy approach for quantitative multiparameter evaluation and classification of IOL vacuoles depending on their critical optical characteristics including vacuole size, density, shape, and orientation within the IOL material. Using the multiparameter database developed by evaluating vacuole characteristics, we established a classification grading system that can be used to evaluate vacuole effects on light scattering. Hindawi 2019-08-04 /pmc/articles/PMC6701293/ /pubmed/31467695 http://dx.doi.org/10.1155/2019/7929014 Text en Copyright © 2019 Vincent Spiezio et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Spiezio, Vincent
Walker, Bennett N.
Calogero, Don
Ilev, Ilko K.
Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title_full Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title_fullStr Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title_full_unstemmed Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title_short Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
title_sort quantitative multiparameter evaluation of vacuoles in intraocular lenses employing a high-magnification digital microscopy method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701293/
https://www.ncbi.nlm.nih.gov/pubmed/31467695
http://dx.doi.org/10.1155/2019/7929014
work_keys_str_mv AT spieziovincent quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod
AT walkerbennettn quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod
AT calogerodon quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod
AT ilevilkok quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod