Cargando…
Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method
As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701293/ https://www.ncbi.nlm.nih.gov/pubmed/31467695 http://dx.doi.org/10.1155/2019/7929014 |
_version_ | 1783445024467320832 |
---|---|
author | Spiezio, Vincent Walker, Bennett N. Calogero, Don Ilev, Ilko K. |
author_facet | Spiezio, Vincent Walker, Bennett N. Calogero, Don Ilev, Ilko K. |
author_sort | Spiezio, Vincent |
collection | PubMed |
description | As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement. This unwanted scatter is of particular concern for patients viewing bright light in reduced-light conditions such as when driving at night, as the scattered light toward the retina can cause temporary blindness. In this study, we have developed and implemented an accurate test methodology based on a high-magnification digital microscopy approach for quantitative multiparameter evaluation and classification of IOL vacuoles depending on their critical optical characteristics including vacuole size, density, shape, and orientation within the IOL material. Using the multiparameter database developed by evaluating vacuole characteristics, we established a classification grading system that can be used to evaluate vacuole effects on light scattering. |
format | Online Article Text |
id | pubmed-6701293 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-67012932019-08-29 Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method Spiezio, Vincent Walker, Bennett N. Calogero, Don Ilev, Ilko K. J Ophthalmol Research Article As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement. This unwanted scatter is of particular concern for patients viewing bright light in reduced-light conditions such as when driving at night, as the scattered light toward the retina can cause temporary blindness. In this study, we have developed and implemented an accurate test methodology based on a high-magnification digital microscopy approach for quantitative multiparameter evaluation and classification of IOL vacuoles depending on their critical optical characteristics including vacuole size, density, shape, and orientation within the IOL material. Using the multiparameter database developed by evaluating vacuole characteristics, we established a classification grading system that can be used to evaluate vacuole effects on light scattering. Hindawi 2019-08-04 /pmc/articles/PMC6701293/ /pubmed/31467695 http://dx.doi.org/10.1155/2019/7929014 Text en Copyright © 2019 Vincent Spiezio et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Spiezio, Vincent Walker, Bennett N. Calogero, Don Ilev, Ilko K. Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title | Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title_full | Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title_fullStr | Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title_full_unstemmed | Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title_short | Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method |
title_sort | quantitative multiparameter evaluation of vacuoles in intraocular lenses employing a high-magnification digital microscopy method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701293/ https://www.ncbi.nlm.nih.gov/pubmed/31467695 http://dx.doi.org/10.1155/2019/7929014 |
work_keys_str_mv | AT spieziovincent quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod AT walkerbennettn quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod AT calogerodon quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod AT ilevilkok quantitativemultiparameterevaluationofvacuolesinintraocularlensesemployingahighmagnificationdigitalmicroscopymethod |