Hybrid optimization based on non-coplanar needles for brachytherapy dose planning

PURPOSE: An ideal dose distribution in a target is the ultimate goal of preoperative dose planning. Furthermore, avoiding vital organs or tissues such as blood vessels or bones during the puncture procedure is significant in low-dose-rate brachytherapy. The aim of this work is to develop a hybrid in...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Xiaodong, Yang, Zhiyong, Jiang, Shan, Zhang, Guobin, Huo, Bin, Chai, Shude
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701384/
https://www.ncbi.nlm.nih.gov/pubmed/31435434
http://dx.doi.org/10.5114/jcb.2019.86167
_version_ 1783445046678257664
author Ma, Xiaodong
Yang, Zhiyong
Jiang, Shan
Zhang, Guobin
Huo, Bin
Chai, Shude
author_facet Ma, Xiaodong
Yang, Zhiyong
Jiang, Shan
Zhang, Guobin
Huo, Bin
Chai, Shude
author_sort Ma, Xiaodong
collection PubMed
description PURPOSE: An ideal dose distribution in a target is the ultimate goal of preoperative dose planning. Furthermore, avoiding vital organs or tissues such as blood vessels or bones during the puncture procedure is significant in low-dose-rate brachytherapy. The aim of this work is to develop a hybrid inverse optimization method based on non-coplanar needles to assist the physician during conformal dose planning, which cannot be properly achieved with a traditional coplanar template. MATERIAL AND METHODS: The hybrid inverse optimization technique include two novel technologies: an inverse optimization algorithm and a dose volume histogram evaluation method. Brachytherapy treatment planning system was designed as an experimental platform. Left lung adenocarcinoma case was used to test the performance of the method in non-coplanar and coplanar needles, and malignant tumor of spine case was involved to test the practical application of this technique. In addition, the optimization time of every test was also recorded. RESULTS: The proposed method can achieve an ideal dose distribution, avoiding vital organs (bones). In the first experiment, 13 non-coplanar needles and 24 seeds were used to get an ideal dose distribution to cover the target, whereas 11 coplanar needles and 23 seeds were used to cover the same target. In the second experiment, the new method used 22 non-coplanar needles and 65 seeds to cover the target, while 63 seeds and 22 needles were used in the actual operation. In addition, the computation time of the hybrid inverse optimization method was 20.5 seconds in the tumor of 94.67 cm(3) by using 22 needles, which was fast enough for clinical application. CONCLUSIONS: The hybrid inverse optimization method achieved high conformity in the clinical practice. The non-coplanar needle can help to achieve a better dose distribution than the coplanar needle.
format Online
Article
Text
id pubmed-6701384
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-67013842019-08-21 Hybrid optimization based on non-coplanar needles for brachytherapy dose planning Ma, Xiaodong Yang, Zhiyong Jiang, Shan Zhang, Guobin Huo, Bin Chai, Shude J Contemp Brachytherapy Original Paper PURPOSE: An ideal dose distribution in a target is the ultimate goal of preoperative dose planning. Furthermore, avoiding vital organs or tissues such as blood vessels or bones during the puncture procedure is significant in low-dose-rate brachytherapy. The aim of this work is to develop a hybrid inverse optimization method based on non-coplanar needles to assist the physician during conformal dose planning, which cannot be properly achieved with a traditional coplanar template. MATERIAL AND METHODS: The hybrid inverse optimization technique include two novel technologies: an inverse optimization algorithm and a dose volume histogram evaluation method. Brachytherapy treatment planning system was designed as an experimental platform. Left lung adenocarcinoma case was used to test the performance of the method in non-coplanar and coplanar needles, and malignant tumor of spine case was involved to test the practical application of this technique. In addition, the optimization time of every test was also recorded. RESULTS: The proposed method can achieve an ideal dose distribution, avoiding vital organs (bones). In the first experiment, 13 non-coplanar needles and 24 seeds were used to get an ideal dose distribution to cover the target, whereas 11 coplanar needles and 23 seeds were used to cover the same target. In the second experiment, the new method used 22 non-coplanar needles and 65 seeds to cover the target, while 63 seeds and 22 needles were used in the actual operation. In addition, the computation time of the hybrid inverse optimization method was 20.5 seconds in the tumor of 94.67 cm(3) by using 22 needles, which was fast enough for clinical application. CONCLUSIONS: The hybrid inverse optimization method achieved high conformity in the clinical practice. The non-coplanar needle can help to achieve a better dose distribution than the coplanar needle. Termedia Publishing House 2019-06-28 2019-06 /pmc/articles/PMC6701384/ /pubmed/31435434 http://dx.doi.org/10.5114/jcb.2019.86167 Text en Copyright: © 2019 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Ma, Xiaodong
Yang, Zhiyong
Jiang, Shan
Zhang, Guobin
Huo, Bin
Chai, Shude
Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title_full Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title_fullStr Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title_full_unstemmed Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title_short Hybrid optimization based on non-coplanar needles for brachytherapy dose planning
title_sort hybrid optimization based on non-coplanar needles for brachytherapy dose planning
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6701384/
https://www.ncbi.nlm.nih.gov/pubmed/31435434
http://dx.doi.org/10.5114/jcb.2019.86167
work_keys_str_mv AT maxiaodong hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning
AT yangzhiyong hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning
AT jiangshan hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning
AT zhangguobin hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning
AT huobin hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning
AT chaishude hybridoptimizationbasedonnoncoplanarneedlesforbrachytherapydoseplanning