Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study

BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emiss...

Descripción completa

Detalles Bibliográficos
Autores principales: Cabello, Jorge, Avram, Mihai, Brandl, Felix, Mustafa, Mona, Scherr, Martin, Leucht, Claudia, Leucht, Stefan, Sorg, Christian, Ziegler, Sibylle I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702490/
https://www.ncbi.nlm.nih.gov/pubmed/31428975
http://dx.doi.org/10.1186/s13550-019-0547-0
_version_ 1783445236228292608
author Cabello, Jorge
Avram, Mihai
Brandl, Felix
Mustafa, Mona
Scherr, Martin
Leucht, Claudia
Leucht, Stefan
Sorg, Christian
Ziegler, Sibylle I.
author_facet Cabello, Jorge
Avram, Mihai
Brandl, Felix
Mustafa, Mona
Scherr, Martin
Leucht, Claudia
Leucht, Stefan
Sorg, Christian
Ziegler, Sibylle I.
author_sort Cabello, Jorge
collection PubMed
description BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emission images, and thus in relative activity distributions and time activity curves for different regions. MRI (magnetic resonance imaging)-based AC is an active area of research in PET/MRI neuroimaging, where several groups developed in the last few years different methods to calculate accurate attenuation (μ-)maps. Some AC methods have been evaluated for different PET radioisotopes and pathologies. However, AC in PET/MRI has scantly been investigated in dynamic PET studies where the aim is to get quantitative kinetic parameters, rather than semi-quantitative parameters from static PET studies. In this work, we investigated the impact of AC accuracy in PET image absolute quantification and, more importantly, in the slope of the Patlak analysis based on the simplified reference tissue model, from a dynamic [(18)F]-fluorodopa (FDOPA) PET/MRI study. In the study, we considered the two AC methods provided by the vendor and an in-house AC method based on the dual ultrashort time echo MRI sequence, using as reference a multi-atlas-based AC method based on a T1-weighted MRI sequence. RESULTS: Non-uniform bias in absolute PET quantification across the brain, from − 20% near the skull to − 10% in the central region, was observed using the two vendor’s μ-maps. The AC method developed in-house showed a − 5% and 1% bias, respectively. Our study resulted in a 5–9% overestimation of the PET kinetic parameters with the vendor-provided μ-maps, while our in-house-developed AC method showed < 2% overestimation compared to the atlas-based AC method, using the cerebellar cortex as reference region. The overestimation obtained using the occipital pole as reference region resulted in a 7–10% with the vendor-provided μ-maps, while our in-house-developed AC method showed < 6% overestimation. CONCLUSIONS: PET kinetic analyses based on a reference region are especially sensitive to the non-uniform bias in PET quantification from AC inaccuracies in brain PET/MRI. Depending on the position of the reference region and the bias with respect to the analysed region, kinetic analyses suffer different levels of bias. Considering bone in the μ-map can potentially result in larger errors, compared to the absence of bone, when non-uniformities in PET quantification are introduced.
format Online
Article
Text
id pubmed-6702490
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-67024902019-09-02 Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study Cabello, Jorge Avram, Mihai Brandl, Felix Mustafa, Mona Scherr, Martin Leucht, Claudia Leucht, Stefan Sorg, Christian Ziegler, Sibylle I. EJNMMI Res Original Research BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emission images, and thus in relative activity distributions and time activity curves for different regions. MRI (magnetic resonance imaging)-based AC is an active area of research in PET/MRI neuroimaging, where several groups developed in the last few years different methods to calculate accurate attenuation (μ-)maps. Some AC methods have been evaluated for different PET radioisotopes and pathologies. However, AC in PET/MRI has scantly been investigated in dynamic PET studies where the aim is to get quantitative kinetic parameters, rather than semi-quantitative parameters from static PET studies. In this work, we investigated the impact of AC accuracy in PET image absolute quantification and, more importantly, in the slope of the Patlak analysis based on the simplified reference tissue model, from a dynamic [(18)F]-fluorodopa (FDOPA) PET/MRI study. In the study, we considered the two AC methods provided by the vendor and an in-house AC method based on the dual ultrashort time echo MRI sequence, using as reference a multi-atlas-based AC method based on a T1-weighted MRI sequence. RESULTS: Non-uniform bias in absolute PET quantification across the brain, from − 20% near the skull to − 10% in the central region, was observed using the two vendor’s μ-maps. The AC method developed in-house showed a − 5% and 1% bias, respectively. Our study resulted in a 5–9% overestimation of the PET kinetic parameters with the vendor-provided μ-maps, while our in-house-developed AC method showed < 2% overestimation compared to the atlas-based AC method, using the cerebellar cortex as reference region. The overestimation obtained using the occipital pole as reference region resulted in a 7–10% with the vendor-provided μ-maps, while our in-house-developed AC method showed < 6% overestimation. CONCLUSIONS: PET kinetic analyses based on a reference region are especially sensitive to the non-uniform bias in PET quantification from AC inaccuracies in brain PET/MRI. Depending on the position of the reference region and the bias with respect to the analysed region, kinetic analyses suffer different levels of bias. Considering bone in the μ-map can potentially result in larger errors, compared to the absence of bone, when non-uniformities in PET quantification are introduced. Springer Berlin Heidelberg 2019-08-19 /pmc/articles/PMC6702490/ /pubmed/31428975 http://dx.doi.org/10.1186/s13550-019-0547-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Cabello, Jorge
Avram, Mihai
Brandl, Felix
Mustafa, Mona
Scherr, Martin
Leucht, Claudia
Leucht, Stefan
Sorg, Christian
Ziegler, Sibylle I.
Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title_full Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title_fullStr Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title_full_unstemmed Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title_short Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
title_sort impact of non-uniform attenuation correction in a dynamic [(18)f]-fdopa brain pet/mri study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702490/
https://www.ncbi.nlm.nih.gov/pubmed/31428975
http://dx.doi.org/10.1186/s13550-019-0547-0
work_keys_str_mv AT cabellojorge impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT avrammihai impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT brandlfelix impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT mustafamona impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT scherrmartin impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT leuchtclaudia impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT leuchtstefan impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT sorgchristian impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy
AT zieglersibyllei impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy