Cargando…
Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study
BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emiss...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702490/ https://www.ncbi.nlm.nih.gov/pubmed/31428975 http://dx.doi.org/10.1186/s13550-019-0547-0 |
_version_ | 1783445236228292608 |
---|---|
author | Cabello, Jorge Avram, Mihai Brandl, Felix Mustafa, Mona Scherr, Martin Leucht, Claudia Leucht, Stefan Sorg, Christian Ziegler, Sibylle I. |
author_facet | Cabello, Jorge Avram, Mihai Brandl, Felix Mustafa, Mona Scherr, Martin Leucht, Claudia Leucht, Stefan Sorg, Christian Ziegler, Sibylle I. |
author_sort | Cabello, Jorge |
collection | PubMed |
description | BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emission images, and thus in relative activity distributions and time activity curves for different regions. MRI (magnetic resonance imaging)-based AC is an active area of research in PET/MRI neuroimaging, where several groups developed in the last few years different methods to calculate accurate attenuation (μ-)maps. Some AC methods have been evaluated for different PET radioisotopes and pathologies. However, AC in PET/MRI has scantly been investigated in dynamic PET studies where the aim is to get quantitative kinetic parameters, rather than semi-quantitative parameters from static PET studies. In this work, we investigated the impact of AC accuracy in PET image absolute quantification and, more importantly, in the slope of the Patlak analysis based on the simplified reference tissue model, from a dynamic [(18)F]-fluorodopa (FDOPA) PET/MRI study. In the study, we considered the two AC methods provided by the vendor and an in-house AC method based on the dual ultrashort time echo MRI sequence, using as reference a multi-atlas-based AC method based on a T1-weighted MRI sequence. RESULTS: Non-uniform bias in absolute PET quantification across the brain, from − 20% near the skull to − 10% in the central region, was observed using the two vendor’s μ-maps. The AC method developed in-house showed a − 5% and 1% bias, respectively. Our study resulted in a 5–9% overestimation of the PET kinetic parameters with the vendor-provided μ-maps, while our in-house-developed AC method showed < 2% overestimation compared to the atlas-based AC method, using the cerebellar cortex as reference region. The overestimation obtained using the occipital pole as reference region resulted in a 7–10% with the vendor-provided μ-maps, while our in-house-developed AC method showed < 6% overestimation. CONCLUSIONS: PET kinetic analyses based on a reference region are especially sensitive to the non-uniform bias in PET quantification from AC inaccuracies in brain PET/MRI. Depending on the position of the reference region and the bias with respect to the analysed region, kinetic analyses suffer different levels of bias. Considering bone in the μ-map can potentially result in larger errors, compared to the absence of bone, when non-uniformities in PET quantification are introduced. |
format | Online Article Text |
id | pubmed-6702490 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-67024902019-09-02 Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study Cabello, Jorge Avram, Mihai Brandl, Felix Mustafa, Mona Scherr, Martin Leucht, Claudia Leucht, Stefan Sorg, Christian Ziegler, Sibylle I. EJNMMI Res Original Research BACKGROUND: PET (positron emission tomography) biokinetic modelling relies on accurate quantitative data. One of the main corrections required in PET imaging to obtain high quantitative accuracy is tissue attenuation correction (AC). Incorrect non-uniform PET-AC may result in local bias in the emission images, and thus in relative activity distributions and time activity curves for different regions. MRI (magnetic resonance imaging)-based AC is an active area of research in PET/MRI neuroimaging, where several groups developed in the last few years different methods to calculate accurate attenuation (μ-)maps. Some AC methods have been evaluated for different PET radioisotopes and pathologies. However, AC in PET/MRI has scantly been investigated in dynamic PET studies where the aim is to get quantitative kinetic parameters, rather than semi-quantitative parameters from static PET studies. In this work, we investigated the impact of AC accuracy in PET image absolute quantification and, more importantly, in the slope of the Patlak analysis based on the simplified reference tissue model, from a dynamic [(18)F]-fluorodopa (FDOPA) PET/MRI study. In the study, we considered the two AC methods provided by the vendor and an in-house AC method based on the dual ultrashort time echo MRI sequence, using as reference a multi-atlas-based AC method based on a T1-weighted MRI sequence. RESULTS: Non-uniform bias in absolute PET quantification across the brain, from − 20% near the skull to − 10% in the central region, was observed using the two vendor’s μ-maps. The AC method developed in-house showed a − 5% and 1% bias, respectively. Our study resulted in a 5–9% overestimation of the PET kinetic parameters with the vendor-provided μ-maps, while our in-house-developed AC method showed < 2% overestimation compared to the atlas-based AC method, using the cerebellar cortex as reference region. The overestimation obtained using the occipital pole as reference region resulted in a 7–10% with the vendor-provided μ-maps, while our in-house-developed AC method showed < 6% overestimation. CONCLUSIONS: PET kinetic analyses based on a reference region are especially sensitive to the non-uniform bias in PET quantification from AC inaccuracies in brain PET/MRI. Depending on the position of the reference region and the bias with respect to the analysed region, kinetic analyses suffer different levels of bias. Considering bone in the μ-map can potentially result in larger errors, compared to the absence of bone, when non-uniformities in PET quantification are introduced. Springer Berlin Heidelberg 2019-08-19 /pmc/articles/PMC6702490/ /pubmed/31428975 http://dx.doi.org/10.1186/s13550-019-0547-0 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Original Research Cabello, Jorge Avram, Mihai Brandl, Felix Mustafa, Mona Scherr, Martin Leucht, Claudia Leucht, Stefan Sorg, Christian Ziegler, Sibylle I. Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title | Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title_full | Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title_fullStr | Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title_full_unstemmed | Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title_short | Impact of non-uniform attenuation correction in a dynamic [(18)F]-FDOPA brain PET/MRI study |
title_sort | impact of non-uniform attenuation correction in a dynamic [(18)f]-fdopa brain pet/mri study |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702490/ https://www.ncbi.nlm.nih.gov/pubmed/31428975 http://dx.doi.org/10.1186/s13550-019-0547-0 |
work_keys_str_mv | AT cabellojorge impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT avrammihai impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT brandlfelix impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT mustafamona impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT scherrmartin impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT leuchtclaudia impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT leuchtstefan impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT sorgchristian impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy AT zieglersibyllei impactofnonuniformattenuationcorrectioninadynamic18ffdopabrainpetmristudy |