Cargando…

Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test

Although the majority of early implanted, profoundly deaf children with cochlear implants (CIs), will develop correct pronunciation if they receive adequate oral language stimulation, many of them have difficulties with perceiving minute details of speech. The main aim of this study is to measure th...

Descripción completa

Detalles Bibliográficos
Autores principales: Rødvik, Arne Kirkhorn, Tvete, Ole, Torkildsen, Janne von Koss, Wie, Ona Bø, Skaug, Ingebjørg, Silvola, Juha Tapio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702790/
https://www.ncbi.nlm.nih.gov/pubmed/31474900
http://dx.doi.org/10.3389/fpsyg.2019.01813
_version_ 1783445297833181184
author Rødvik, Arne Kirkhorn
Tvete, Ole
Torkildsen, Janne von Koss
Wie, Ona Bø
Skaug, Ingebjørg
Silvola, Juha Tapio
author_facet Rødvik, Arne Kirkhorn
Tvete, Ole
Torkildsen, Janne von Koss
Wie, Ona Bø
Skaug, Ingebjørg
Silvola, Juha Tapio
author_sort Rødvik, Arne Kirkhorn
collection PubMed
description Although the majority of early implanted, profoundly deaf children with cochlear implants (CIs), will develop correct pronunciation if they receive adequate oral language stimulation, many of them have difficulties with perceiving minute details of speech. The main aim of this study is to measure the confusion of consonants and vowels in well-performing children and adolescents with CIs. The study also aims to investigate how age at onset of severe to profound deafness influences perception. The participants are 36 children and adolescents with CIs (18 girls), with a mean (SD) age of 11.6 (3.0) years (range: 5.9–16.0 years). Twenty-nine of them are prelingually deaf and seven are postlingually deaf. Two reference groups of normal-hearing (NH) 6- and 13-year-olds are included. Consonant and vowel perception is measured by repetition of 16 bisyllabic vowel-consonant-vowel nonsense words and nine monosyllabic consonant-vowel-consonant nonsense words in an open-set design. For the participants with CIs, consonants were mostly confused with consonants with the same voicing and manner, and the mean (SD) voiced consonant repetition score, 63.9 (10.6)%, was considerably lower than the mean (SD) unvoiced consonant score, 76.9 (9.3)%. There was a devoicing bias for the stops; unvoiced stops were confused with other unvoiced stops and not with voiced stops, and voiced stops were confused with both unvoiced stops and other voiced stops. The mean (SD) vowel repetition score was 85.2 (10.6)% and there was a bias in the confusions of [i:] and [y:]; [y:] was perceived as [i:] twice as often as [y:] was repeated correctly. Subgroup analyses showed no statistically significant differences between the consonant scores for pre- and postlingually deaf participants. For the NH participants, the consonant repetition scores were substantially higher and the difference between voiced and unvoiced consonant repetition scores considerably lower than for the participants with CIs. The participants with CIs obtained scores close to ceiling on vowels and real-word monosyllables, but their perception was substantially lower for voiced consonants. This may partly be related to limitations in the CI technology for the transmission of low-frequency sounds, such as insertion depth of the electrode and ability to convey temporal information.
format Online
Article
Text
id pubmed-6702790
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-67027902019-08-30 Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test Rødvik, Arne Kirkhorn Tvete, Ole Torkildsen, Janne von Koss Wie, Ona Bø Skaug, Ingebjørg Silvola, Juha Tapio Front Psychol Psychology Although the majority of early implanted, profoundly deaf children with cochlear implants (CIs), will develop correct pronunciation if they receive adequate oral language stimulation, many of them have difficulties with perceiving minute details of speech. The main aim of this study is to measure the confusion of consonants and vowels in well-performing children and adolescents with CIs. The study also aims to investigate how age at onset of severe to profound deafness influences perception. The participants are 36 children and adolescents with CIs (18 girls), with a mean (SD) age of 11.6 (3.0) years (range: 5.9–16.0 years). Twenty-nine of them are prelingually deaf and seven are postlingually deaf. Two reference groups of normal-hearing (NH) 6- and 13-year-olds are included. Consonant and vowel perception is measured by repetition of 16 bisyllabic vowel-consonant-vowel nonsense words and nine monosyllabic consonant-vowel-consonant nonsense words in an open-set design. For the participants with CIs, consonants were mostly confused with consonants with the same voicing and manner, and the mean (SD) voiced consonant repetition score, 63.9 (10.6)%, was considerably lower than the mean (SD) unvoiced consonant score, 76.9 (9.3)%. There was a devoicing bias for the stops; unvoiced stops were confused with other unvoiced stops and not with voiced stops, and voiced stops were confused with both unvoiced stops and other voiced stops. The mean (SD) vowel repetition score was 85.2 (10.6)% and there was a bias in the confusions of [i:] and [y:]; [y:] was perceived as [i:] twice as often as [y:] was repeated correctly. Subgroup analyses showed no statistically significant differences between the consonant scores for pre- and postlingually deaf participants. For the NH participants, the consonant repetition scores were substantially higher and the difference between voiced and unvoiced consonant repetition scores considerably lower than for the participants with CIs. The participants with CIs obtained scores close to ceiling on vowels and real-word monosyllables, but their perception was substantially lower for voiced consonants. This may partly be related to limitations in the CI technology for the transmission of low-frequency sounds, such as insertion depth of the electrode and ability to convey temporal information. Frontiers Media S.A. 2019-08-14 /pmc/articles/PMC6702790/ /pubmed/31474900 http://dx.doi.org/10.3389/fpsyg.2019.01813 Text en Copyright © 2019 Rødvik, Tvete, Torkildsen, Wie, Skaug and Silvola. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Psychology
Rødvik, Arne Kirkhorn
Tvete, Ole
Torkildsen, Janne von Koss
Wie, Ona Bø
Skaug, Ingebjørg
Silvola, Juha Tapio
Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title_full Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title_fullStr Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title_full_unstemmed Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title_short Consonant and Vowel Confusions in Well-Performing Children and Adolescents With Cochlear Implants, Measured by a Nonsense Syllable Repetition Test
title_sort consonant and vowel confusions in well-performing children and adolescents with cochlear implants, measured by a nonsense syllable repetition test
topic Psychology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6702790/
https://www.ncbi.nlm.nih.gov/pubmed/31474900
http://dx.doi.org/10.3389/fpsyg.2019.01813
work_keys_str_mv AT rødvikarnekirkhorn consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest
AT tveteole consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest
AT torkildsenjannevonkoss consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest
AT wieonabø consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest
AT skaugingebjørg consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest
AT silvolajuhatapio consonantandvowelconfusionsinwellperformingchildrenandadolescentswithcochlearimplantsmeasuredbyanonsensesyllablerepetitiontest