Cargando…

Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image

AIMS: Manual planimetry is the current method defining infarct volume on magnetic resonance (MR) diffusion-weighted image. ABC/2 method is an ellipsoid geometric formula with advantage estimation of intraparenchymal hemorrhage volume. Our study aimed to find the reliability and reproducibility of AB...

Descripción completa

Detalles Bibliográficos
Autores principales: Sananmuang, Thiparom, Dejsiripongsa, Thanya, Keandoungchun, Jesada, Apirakkan, Mungkorn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6703032/
https://www.ncbi.nlm.nih.gov/pubmed/31497105
http://dx.doi.org/10.4103/ajns.AJNS_68_19
_version_ 1783445353167585280
author Sananmuang, Thiparom
Dejsiripongsa, Thanya
Keandoungchun, Jesada
Apirakkan, Mungkorn
author_facet Sananmuang, Thiparom
Dejsiripongsa, Thanya
Keandoungchun, Jesada
Apirakkan, Mungkorn
author_sort Sananmuang, Thiparom
collection PubMed
description AIMS: Manual planimetry is the current method defining infarct volume on magnetic resonance (MR) diffusion-weighted image. ABC/2 method is an ellipsoid geometric formula with advantage estimation of intraparenchymal hemorrhage volume. Our study aimed to find the reliability and reproducibility of ABC/2 method compared to manual planimetric segmentation method. SETTINGS AND DESIGN: This was a cross-sectional analytical study with retrospective and prospective data collection. SUBJECTS AND METHODS: A total of 109 patients with acute ischemic stroke and underwent MR images at Ramathibodi Hospital were retrospectively reviewed. Relationship between manual planimetric segmentation and ABC/2 methods (nonadjusted ABC/2 method and adjusted ABC*/2 method) was determined using Wilcoxon signed-rank test, linear regression analysis, and Bland–Altman plot. Subgroup analysis by location, onset, shape, and size of infarct volume was performed. Interobserver reliability was established using intraclass correlation coefficient and Bland–Altman plot. STATISTICAL ANALYSIS USED: Wilcoxon signed-rank test, linear regression analysis, and Bland–Altman plot were used for statistical analysis. RESULTS: Infarct volume measured with nonadjusted ABC/2 method (23.56, 48.81, 4.25, 0.11, 318.94) (mean, standard deviation, median, minimum, maximum) and adjusted ABC*/2 method (13.37, 28.3, 2.08, 0.06, 170.10) was smaller than manual planimetric method (28.50, 58.64, 5.56, 0.27, 335.49) (P < 0.001). Linear regression's slope confirmed underestimation of volume infarct. In round-to-ellipsoid shape and white matter group, the differences found between nonadjusted ABC/2 and manual planimetric methods are not statistically significant. CONCLUSIONS: ABC/2 method is a simple, rapid, and reproducible method with an excellent positive correlation of both adjusted and nonadjusted ABC/2 methods to manual planimetric segmentation method but tendency to underestimated infarct volume. High interobserver reliability and good agreement between two observers have been established. The utilization of nonadjusted ABC/2 method should be used with caution due to its tendency to underestimate the infarct volume.
format Online
Article
Text
id pubmed-6703032
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-67030322019-09-06 Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image Sananmuang, Thiparom Dejsiripongsa, Thanya Keandoungchun, Jesada Apirakkan, Mungkorn Asian J Neurosurg Original Article AIMS: Manual planimetry is the current method defining infarct volume on magnetic resonance (MR) diffusion-weighted image. ABC/2 method is an ellipsoid geometric formula with advantage estimation of intraparenchymal hemorrhage volume. Our study aimed to find the reliability and reproducibility of ABC/2 method compared to manual planimetric segmentation method. SETTINGS AND DESIGN: This was a cross-sectional analytical study with retrospective and prospective data collection. SUBJECTS AND METHODS: A total of 109 patients with acute ischemic stroke and underwent MR images at Ramathibodi Hospital were retrospectively reviewed. Relationship between manual planimetric segmentation and ABC/2 methods (nonadjusted ABC/2 method and adjusted ABC*/2 method) was determined using Wilcoxon signed-rank test, linear regression analysis, and Bland–Altman plot. Subgroup analysis by location, onset, shape, and size of infarct volume was performed. Interobserver reliability was established using intraclass correlation coefficient and Bland–Altman plot. STATISTICAL ANALYSIS USED: Wilcoxon signed-rank test, linear regression analysis, and Bland–Altman plot were used for statistical analysis. RESULTS: Infarct volume measured with nonadjusted ABC/2 method (23.56, 48.81, 4.25, 0.11, 318.94) (mean, standard deviation, median, minimum, maximum) and adjusted ABC*/2 method (13.37, 28.3, 2.08, 0.06, 170.10) was smaller than manual planimetric method (28.50, 58.64, 5.56, 0.27, 335.49) (P < 0.001). Linear regression's slope confirmed underestimation of volume infarct. In round-to-ellipsoid shape and white matter group, the differences found between nonadjusted ABC/2 and manual planimetric methods are not statistically significant. CONCLUSIONS: ABC/2 method is a simple, rapid, and reproducible method with an excellent positive correlation of both adjusted and nonadjusted ABC/2 methods to manual planimetric segmentation method but tendency to underestimated infarct volume. High interobserver reliability and good agreement between two observers have been established. The utilization of nonadjusted ABC/2 method should be used with caution due to its tendency to underestimate the infarct volume. Wolters Kluwer - Medknow 2019 /pmc/articles/PMC6703032/ /pubmed/31497105 http://dx.doi.org/10.4103/ajns.AJNS_68_19 Text en Copyright: © 2019 Asian Journal of Neurosurgery http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sananmuang, Thiparom
Dejsiripongsa, Thanya
Keandoungchun, Jesada
Apirakkan, Mungkorn
Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title_full Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title_fullStr Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title_full_unstemmed Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title_short Reliability of ABC/2 Method in Measuring of Infarct Volume in Magnetic Resonance Diffusion-Weighted Image
title_sort reliability of abc/2 method in measuring of infarct volume in magnetic resonance diffusion-weighted image
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6703032/
https://www.ncbi.nlm.nih.gov/pubmed/31497105
http://dx.doi.org/10.4103/ajns.AJNS_68_19
work_keys_str_mv AT sananmuangthiparom reliabilityofabc2methodinmeasuringofinfarctvolumeinmagneticresonancediffusionweightedimage
AT dejsiripongsathanya reliabilityofabc2methodinmeasuringofinfarctvolumeinmagneticresonancediffusionweightedimage
AT keandoungchunjesada reliabilityofabc2methodinmeasuringofinfarctvolumeinmagneticresonancediffusionweightedimage
AT apirakkanmungkorn reliabilityofabc2methodinmeasuringofinfarctvolumeinmagneticresonancediffusionweightedimage