Cargando…

ST analysis of the fetal electrocardiogram – Comments on recent experimental data

In their paper, Andriessen at al present a validation of fetal ECG analysis and the clinical STAN device in midgestation fetal lambs exposed to 25 minutes of umbilical cord occlusion. The study presents results that contrast remarkably from previously published experimental data which raises a numbe...

Descripción completa

Detalles Bibliográficos
Autores principales: Kjellmer, Ingemar, Lindecrantz, Kaj, Rosén, Karl G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6706221/
https://www.ncbi.nlm.nih.gov/pubmed/31437186
http://dx.doi.org/10.1371/journal.pone.0221210
_version_ 1783445671618019328
author Kjellmer, Ingemar
Lindecrantz, Kaj
Rosén, Karl G.
author_facet Kjellmer, Ingemar
Lindecrantz, Kaj
Rosén, Karl G.
author_sort Kjellmer, Ingemar
collection PubMed
description In their paper, Andriessen at al present a validation of fetal ECG analysis and the clinical STAN device in midgestation fetal lambs exposed to 25 minutes of umbilical cord occlusion. The study presents results that contrast remarkably from previously published experimental data which raises a number of questions and comments. The most striking finding of Andriessen et al is the recording of an extremely high number of alarms from the STAN equipment during control conditions when no alarms at all are expected. These patterns have never been seen, neither in the clinical situation nor in our own fetal sheep studies. The reason for this becomes apparent when their way of recording the FECG is scrutinized. In their assessment of STAN, Andriessen at al use an assumed negative aVF lead with the assumption that it will reflect the FECG in the same way as the unipolar scalp lead used clinically. The signal used for disqualification of STAN is itself not qualified to properly represent the fetal scalp lead signal that STAN is designed for. To question a proven technology is fully accepted but those attempting would be asked to argue along fully validated data and related analysis including questioning of their own data.
format Online
Article
Text
id pubmed-6706221
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-67062212019-09-04 ST analysis of the fetal electrocardiogram – Comments on recent experimental data Kjellmer, Ingemar Lindecrantz, Kaj Rosén, Karl G. PLoS One Formal Comment In their paper, Andriessen at al present a validation of fetal ECG analysis and the clinical STAN device in midgestation fetal lambs exposed to 25 minutes of umbilical cord occlusion. The study presents results that contrast remarkably from previously published experimental data which raises a number of questions and comments. The most striking finding of Andriessen et al is the recording of an extremely high number of alarms from the STAN equipment during control conditions when no alarms at all are expected. These patterns have never been seen, neither in the clinical situation nor in our own fetal sheep studies. The reason for this becomes apparent when their way of recording the FECG is scrutinized. In their assessment of STAN, Andriessen at al use an assumed negative aVF lead with the assumption that it will reflect the FECG in the same way as the unipolar scalp lead used clinically. The signal used for disqualification of STAN is itself not qualified to properly represent the fetal scalp lead signal that STAN is designed for. To question a proven technology is fully accepted but those attempting would be asked to argue along fully validated data and related analysis including questioning of their own data. Public Library of Science 2019-08-22 /pmc/articles/PMC6706221/ /pubmed/31437186 http://dx.doi.org/10.1371/journal.pone.0221210 Text en © 2019 Kjellmer et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Formal Comment
Kjellmer, Ingemar
Lindecrantz, Kaj
Rosén, Karl G.
ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title_full ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title_fullStr ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title_full_unstemmed ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title_short ST analysis of the fetal electrocardiogram – Comments on recent experimental data
title_sort st analysis of the fetal electrocardiogram – comments on recent experimental data
topic Formal Comment
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6706221/
https://www.ncbi.nlm.nih.gov/pubmed/31437186
http://dx.doi.org/10.1371/journal.pone.0221210
work_keys_str_mv AT kjellmeringemar stanalysisofthefetalelectrocardiogramcommentsonrecentexperimentaldata
AT lindecrantzkaj stanalysisofthefetalelectrocardiogramcommentsonrecentexperimentaldata
AT rosenkarlg stanalysisofthefetalelectrocardiogramcommentsonrecentexperimentaldata