Cargando…
Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma
BACKGROUND: Recent technical advances in the extraction of dermal interstitial fluid (ISF) have stimulated interest in using this rather unexploited biofluid as an alternative to blood for detection and prediction of disease. However, knowledge about the presence of useful biomarkers for health moni...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6708155/ https://www.ncbi.nlm.nih.gov/pubmed/31443723 http://dx.doi.org/10.1186/s12944-019-1107-3 |
_version_ | 1783445962705862656 |
---|---|
author | Nilsson, Anders K. Sjöbom, Ulrika Christenson, Karin Hellström, Ann |
author_facet | Nilsson, Anders K. Sjöbom, Ulrika Christenson, Karin Hellström, Ann |
author_sort | Nilsson, Anders K. |
collection | PubMed |
description | BACKGROUND: Recent technical advances in the extraction of dermal interstitial fluid (ISF) have stimulated interest in using this rather unexploited biofluid as an alternative to blood for detection and prediction of disease. However, knowledge about the presence of useful biomarkers for health monitoring in ISF is still limited. In this study, we characterized the lipidome of human suction blister fluid (SBF) as a surrogate for pure ISF and compared it to that of plasma. METHODS: Plasma and SBF samples were obtained from 18 healthy human volunteers after an overnight fast. Total lipids were extracted and analyzed by liquid chromatography-tandem mass spectrometry. One hundred ninety-three lipid species covering 10 complex lipid classes were detected and quantified in both plasma and SBF using multiple reaction monitoring. A fraction of the lipid extract was subjected to alkaline transesterification and fatty acid methyl esters were analyzed by gas chromatography–mass spectrometry. RESULTS: The total concentration of lipids in SBF was 17% of the plasma lipid concentration. The molar fraction of lipid species within lipid classes, as well as total fatty acids, showed a generally high correlation between plasma and SBF. However, SBF had larger fractions of lysophospholipids and diglycerides relative to plasma, and consequently less diacylphospholipids and triglycerides. Principal component analysis revealed that the interindividual variation in SBF lipid profiles was considerably larger than the within-subject variation between plasma and SBF. CONCLUSIONS: Plasma and SBF lipid profiles show high correlation and SBF could be used interchangeably with blood for the analysis of major lipids used in health monitoring. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12944-019-1107-3) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-6708155 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-67081552019-08-28 Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma Nilsson, Anders K. Sjöbom, Ulrika Christenson, Karin Hellström, Ann Lipids Health Dis Research BACKGROUND: Recent technical advances in the extraction of dermal interstitial fluid (ISF) have stimulated interest in using this rather unexploited biofluid as an alternative to blood for detection and prediction of disease. However, knowledge about the presence of useful biomarkers for health monitoring in ISF is still limited. In this study, we characterized the lipidome of human suction blister fluid (SBF) as a surrogate for pure ISF and compared it to that of plasma. METHODS: Plasma and SBF samples were obtained from 18 healthy human volunteers after an overnight fast. Total lipids were extracted and analyzed by liquid chromatography-tandem mass spectrometry. One hundred ninety-three lipid species covering 10 complex lipid classes were detected and quantified in both plasma and SBF using multiple reaction monitoring. A fraction of the lipid extract was subjected to alkaline transesterification and fatty acid methyl esters were analyzed by gas chromatography–mass spectrometry. RESULTS: The total concentration of lipids in SBF was 17% of the plasma lipid concentration. The molar fraction of lipid species within lipid classes, as well as total fatty acids, showed a generally high correlation between plasma and SBF. However, SBF had larger fractions of lysophospholipids and diglycerides relative to plasma, and consequently less diacylphospholipids and triglycerides. Principal component analysis revealed that the interindividual variation in SBF lipid profiles was considerably larger than the within-subject variation between plasma and SBF. CONCLUSIONS: Plasma and SBF lipid profiles show high correlation and SBF could be used interchangeably with blood for the analysis of major lipids used in health monitoring. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12944-019-1107-3) contains supplementary material, which is available to authorized users. BioMed Central 2019-08-24 /pmc/articles/PMC6708155/ /pubmed/31443723 http://dx.doi.org/10.1186/s12944-019-1107-3 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Nilsson, Anders K. Sjöbom, Ulrika Christenson, Karin Hellström, Ann Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title | Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title_full | Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title_fullStr | Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title_full_unstemmed | Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title_short | Lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
title_sort | lipid profiling of suction blister fluid: comparison of lipids in interstitial fluid and plasma |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6708155/ https://www.ncbi.nlm.nih.gov/pubmed/31443723 http://dx.doi.org/10.1186/s12944-019-1107-3 |
work_keys_str_mv | AT nilssonandersk lipidprofilingofsuctionblisterfluidcomparisonoflipidsininterstitialfluidandplasma AT sjobomulrika lipidprofilingofsuctionblisterfluidcomparisonoflipidsininterstitialfluidandplasma AT christensonkarin lipidprofilingofsuctionblisterfluidcomparisonoflipidsininterstitialfluidandplasma AT hellstromann lipidprofilingofsuctionblisterfluidcomparisonoflipidsininterstitialfluidandplasma |