Cargando…

Use of surgical glue for Mason type III radial head fractures: A case report

RATIONALE: A Mason type III radial head fracture, which is characterized by comminuted fragments of the radial head, is a severe injury. Open reduction and internal fixation (ORIF) is an alternative treatment method; however, the technique of using an on-table reduction in combination with surgical...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Da-wei, Hu, Wan-kun, Zhou, Jia-qian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709144/
https://www.ncbi.nlm.nih.gov/pubmed/31145339
http://dx.doi.org/10.1097/MD.0000000000015863
_version_ 1783446141339172864
author Chen, Da-wei
Hu, Wan-kun
Zhou, Jia-qian
author_facet Chen, Da-wei
Hu, Wan-kun
Zhou, Jia-qian
author_sort Chen, Da-wei
collection PubMed
description RATIONALE: A Mason type III radial head fracture, which is characterized by comminuted fragments of the radial head, is a severe injury. Open reduction and internal fixation (ORIF) is an alternative treatment method; however, the technique of using an on-table reduction in combination with surgical glue is rarely reported. PATIENT CONCERNS: A 48-year-old man was admitted to our department with complaints of elbow pain after falling down. Elbow radiography and computed tomography (CT) demonstrated characteristics of fractures before the operation. DIAGNOSIS: Radiographic images showed a Mason type III radial head fracture. INTERVENTIONS: The patient underwent ORIF at our hospital. During the operation, the technique of on-table reconstruction combined with surgical glue was used. OUTCOMES: The patient recovered well and was able to participate in his usual work. LESSONS: Mason type III radial head fractures could be treated with ORIF, and a satisfactory result could be anticipated, thus avoiding a radial head replacement or resection. Anatomical reduction of a comminuted radial head could be obtained via an on-table reconstruction and application of surgical glue.
format Online
Article
Text
id pubmed-6709144
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-67091442019-10-01 Use of surgical glue for Mason type III radial head fractures: A case report Chen, Da-wei Hu, Wan-kun Zhou, Jia-qian Medicine (Baltimore) Research Article RATIONALE: A Mason type III radial head fracture, which is characterized by comminuted fragments of the radial head, is a severe injury. Open reduction and internal fixation (ORIF) is an alternative treatment method; however, the technique of using an on-table reduction in combination with surgical glue is rarely reported. PATIENT CONCERNS: A 48-year-old man was admitted to our department with complaints of elbow pain after falling down. Elbow radiography and computed tomography (CT) demonstrated characteristics of fractures before the operation. DIAGNOSIS: Radiographic images showed a Mason type III radial head fracture. INTERVENTIONS: The patient underwent ORIF at our hospital. During the operation, the technique of on-table reconstruction combined with surgical glue was used. OUTCOMES: The patient recovered well and was able to participate in his usual work. LESSONS: Mason type III radial head fractures could be treated with ORIF, and a satisfactory result could be anticipated, thus avoiding a radial head replacement or resection. Anatomical reduction of a comminuted radial head could be obtained via an on-table reconstruction and application of surgical glue. Wolters Kluwer Health 2019-05-31 /pmc/articles/PMC6709144/ /pubmed/31145339 http://dx.doi.org/10.1097/MD.0000000000015863 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc-nd/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0
spellingShingle Research Article
Chen, Da-wei
Hu, Wan-kun
Zhou, Jia-qian
Use of surgical glue for Mason type III radial head fractures: A case report
title Use of surgical glue for Mason type III radial head fractures: A case report
title_full Use of surgical glue for Mason type III radial head fractures: A case report
title_fullStr Use of surgical glue for Mason type III radial head fractures: A case report
title_full_unstemmed Use of surgical glue for Mason type III radial head fractures: A case report
title_short Use of surgical glue for Mason type III radial head fractures: A case report
title_sort use of surgical glue for mason type iii radial head fractures: a case report
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709144/
https://www.ncbi.nlm.nih.gov/pubmed/31145339
http://dx.doi.org/10.1097/MD.0000000000015863
work_keys_str_mv AT chendawei useofsurgicalglueformasontypeiiiradialheadfracturesacasereport
AT huwankun useofsurgicalglueformasontypeiiiradialheadfracturesacasereport
AT zhoujiaqian useofsurgicalglueformasontypeiiiradialheadfracturesacasereport