Cargando…
Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis
BACKGROUND: More and more automated efficient ultrasound image analysis techniques, such as ultrasound-based computer-aided diagnosis system (CAD), were developed to obtain accurate, reproducible, and more objective diagnosis results for thyroid nodules. So far, whether the diagnostic performance of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer Health
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709241/ https://www.ncbi.nlm.nih.gov/pubmed/31393347 http://dx.doi.org/10.1097/MD.0000000000016379 |
_version_ | 1783446164470759424 |
---|---|
author | Zhao, Wan-Jun Fu, Lin-Ru Huang, Zhi-Mian Zhu, Jing-Qiang Ma, Bu-Yun |
author_facet | Zhao, Wan-Jun Fu, Lin-Ru Huang, Zhi-Mian Zhu, Jing-Qiang Ma, Bu-Yun |
author_sort | Zhao, Wan-Jun |
collection | PubMed |
description | BACKGROUND: More and more automated efficient ultrasound image analysis techniques, such as ultrasound-based computer-aided diagnosis system (CAD), were developed to obtain accurate, reproducible, and more objective diagnosis results for thyroid nodules. So far, whether the diagnostic performance of existing CAD systems can reach the diagnostic level of experienced radiologists is still controversial. The aim of the meta-analysis was to evaluate the accuracy of CAD for thyroid nodules’ diagnosis by reviewing current literatures and summarizing the research status. METHODS: A detailed literature search on PubMed, Embase, and Cochrane Libraries for articles published until December 2018 was carried out. The diagnostic performances of CAD systems vs radiologist were evaluated by meta-analysis. We determined the sensitivity and the specificity across studies, calculated positive and negative likelihood ratios and constructed summary receiver-operating characteristic (SROC) curves. Meta-analysis of studies was performed using a mixed-effect, hierarchical logistic regression model. RESULTS: Five studies with 536 patients and 723 thyroid nodules were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio (DOR) for CAD system were 0.87 (95% confidence interval [CI], 0.73–0.94), 0.79 (95% CI 0.63–0.89), 4.1 (95% CI 2.5–6.9), 0.17 (95% CI 0.09–0.32), and 25 (95% CI 15–42), respectively. The SROC curve indicated that the area under the curve was 0.90 (95% CI 0.87–0.92). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and DOR for experienced radiologists were 0.82 (95% CI 0.69–0.91), 0.83 (95% CI 0.76–0.89), 4.9 (95% CI 3.4–7.0), 0.22 (95% CI 0.12–0.38), and 23 (95% CI 11–46), respectively. The SROC curve indicated that the area under the curve was 0.96 (95% CI 0.94–0.97). CONCLUSION: The sensitivity of the CAD system in the diagnosis of thyroid nodules was similar to that of experienced radiologists. However, the CAD system had lower specificity and DOR than experienced radiologists. The CAD system may play the potential role as a decision-making assistant alongside radiologists in the thyroid nodules’ diagnosis. Future technical improvements would be helpful to increase the accuracy as well as diagnostic efficiency. |
format | Online Article Text |
id | pubmed-6709241 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer Health |
record_format | MEDLINE/PubMed |
spelling | pubmed-67092412019-10-01 Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis Zhao, Wan-Jun Fu, Lin-Ru Huang, Zhi-Mian Zhu, Jing-Qiang Ma, Bu-Yun Medicine (Baltimore) Research Article BACKGROUND: More and more automated efficient ultrasound image analysis techniques, such as ultrasound-based computer-aided diagnosis system (CAD), were developed to obtain accurate, reproducible, and more objective diagnosis results for thyroid nodules. So far, whether the diagnostic performance of existing CAD systems can reach the diagnostic level of experienced radiologists is still controversial. The aim of the meta-analysis was to evaluate the accuracy of CAD for thyroid nodules’ diagnosis by reviewing current literatures and summarizing the research status. METHODS: A detailed literature search on PubMed, Embase, and Cochrane Libraries for articles published until December 2018 was carried out. The diagnostic performances of CAD systems vs radiologist were evaluated by meta-analysis. We determined the sensitivity and the specificity across studies, calculated positive and negative likelihood ratios and constructed summary receiver-operating characteristic (SROC) curves. Meta-analysis of studies was performed using a mixed-effect, hierarchical logistic regression model. RESULTS: Five studies with 536 patients and 723 thyroid nodules were included in this meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio (DOR) for CAD system were 0.87 (95% confidence interval [CI], 0.73–0.94), 0.79 (95% CI 0.63–0.89), 4.1 (95% CI 2.5–6.9), 0.17 (95% CI 0.09–0.32), and 25 (95% CI 15–42), respectively. The SROC curve indicated that the area under the curve was 0.90 (95% CI 0.87–0.92). The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and DOR for experienced radiologists were 0.82 (95% CI 0.69–0.91), 0.83 (95% CI 0.76–0.89), 4.9 (95% CI 3.4–7.0), 0.22 (95% CI 0.12–0.38), and 23 (95% CI 11–46), respectively. The SROC curve indicated that the area under the curve was 0.96 (95% CI 0.94–0.97). CONCLUSION: The sensitivity of the CAD system in the diagnosis of thyroid nodules was similar to that of experienced radiologists. However, the CAD system had lower specificity and DOR than experienced radiologists. The CAD system may play the potential role as a decision-making assistant alongside radiologists in the thyroid nodules’ diagnosis. Future technical improvements would be helpful to increase the accuracy as well as diagnostic efficiency. Wolters Kluwer Health 2019-08-09 /pmc/articles/PMC6709241/ /pubmed/31393347 http://dx.doi.org/10.1097/MD.0000000000016379 Text en Copyright © 2019 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nc/4.0 This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc/4.0 |
spellingShingle | Research Article Zhao, Wan-Jun Fu, Lin-Ru Huang, Zhi-Mian Zhu, Jing-Qiang Ma, Bu-Yun Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title | Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title_full | Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title_fullStr | Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title_full_unstemmed | Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title_short | Effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: A systematic review and meta-analysis |
title_sort | effectiveness evaluation of computer-aided diagnosis system for the diagnosis of thyroid nodules on ultrasound: a systematic review and meta-analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6709241/ https://www.ncbi.nlm.nih.gov/pubmed/31393347 http://dx.doi.org/10.1097/MD.0000000000016379 |
work_keys_str_mv | AT zhaowanjun effectivenessevaluationofcomputeraideddiagnosissystemforthediagnosisofthyroidnodulesonultrasoundasystematicreviewandmetaanalysis AT fulinru effectivenessevaluationofcomputeraideddiagnosissystemforthediagnosisofthyroidnodulesonultrasoundasystematicreviewandmetaanalysis AT huangzhimian effectivenessevaluationofcomputeraideddiagnosissystemforthediagnosisofthyroidnodulesonultrasoundasystematicreviewandmetaanalysis AT zhujingqiang effectivenessevaluationofcomputeraideddiagnosissystemforthediagnosisofthyroidnodulesonultrasoundasystematicreviewandmetaanalysis AT mabuyun effectivenessevaluationofcomputeraideddiagnosissystemforthediagnosisofthyroidnodulesonultrasoundasystematicreviewandmetaanalysis |