Cargando…

Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study

BACKGROUND: Adductor longus tendinopathy is a well-known etiology of chronic groin pain in elite athletes. Surgery is indicated for those who fail conservative treatment. No studies to date have evaluated the feasibility of an ultrasound-guided release of the proximal adductor longus tendon. PURPOSE...

Descripción completa

Detalles Bibliográficos
Autores principales: Boettcher, Brennan J., Hollman, John H., Stuart, Michael J., Finnoff, Jonathan T.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6710695/
https://www.ncbi.nlm.nih.gov/pubmed/31489333
http://dx.doi.org/10.1177/2325967119866010
_version_ 1783446388536770560
author Boettcher, Brennan J.
Hollman, John H.
Stuart, Michael J.
Finnoff, Jonathan T.
author_facet Boettcher, Brennan J.
Hollman, John H.
Stuart, Michael J.
Finnoff, Jonathan T.
author_sort Boettcher, Brennan J.
collection PubMed
description BACKGROUND: Adductor longus tendinopathy is a well-known etiology of chronic groin pain in elite athletes. Surgery is indicated for those who fail conservative treatment. No studies to date have evaluated the feasibility of an ultrasound-guided release of the proximal adductor longus tendon. PURPOSE/HYPOTHESIS: The primary aim of this study was to determine the feasibility of an ultrasound-guided selective adductor longus release with a cutting wire. A secondary aim was to determine safety by avoiding injury to adjacent structures. We hypothesized that the proximal adductor longus tendon can be released under ultrasound guidance with a cutting wire without injury to adjacent neurovascular or genitourinary structures. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten adductor longus tendons (5 cadaveric specimens) from 4 males and 1 female between 76 and 89 years of age with a mean body mass index of 21.9 kg/m(2) (range, 16.8-29.6 kg/m(2)) were used during this study. A single experienced physician sonographer performed ultrasound-guided proximal adductor longus tendon releases on all cadaveric specimens using a cutting wire. Dissection was performed by a second physician to determine the completeness of the tendon transections and to detect injury to adjacent neurovascular or genitourinary structures. RESULTS: All 10 adductor longus tendons were transected. Eight of 10 transections were complete, whereas in 2 transections, >99% of the tendon was transected. There were no injuries to adjacent genitourinary or neurovascular structures. CONCLUSION: Ultrasound-guided adductor tendon release is feasible and safe in a cadaveric model. Further translational research should be performed to determine whether these results can be replicated in the clinical setting. CLINICAL RELEVANCE: Adductor longus tendinopathy frequently requires surgical intervention and prolonged time away from sport. The present study suggests that a selective adductor longus tendon release can be performed with ultrasound guidance. This procedure warrants further translational research to explore its use in clinical practice.
format Online
Article
Text
id pubmed-6710695
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-67106952019-09-05 Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study Boettcher, Brennan J. Hollman, John H. Stuart, Michael J. Finnoff, Jonathan T. Orthop J Sports Med Article BACKGROUND: Adductor longus tendinopathy is a well-known etiology of chronic groin pain in elite athletes. Surgery is indicated for those who fail conservative treatment. No studies to date have evaluated the feasibility of an ultrasound-guided release of the proximal adductor longus tendon. PURPOSE/HYPOTHESIS: The primary aim of this study was to determine the feasibility of an ultrasound-guided selective adductor longus release with a cutting wire. A secondary aim was to determine safety by avoiding injury to adjacent structures. We hypothesized that the proximal adductor longus tendon can be released under ultrasound guidance with a cutting wire without injury to adjacent neurovascular or genitourinary structures. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten adductor longus tendons (5 cadaveric specimens) from 4 males and 1 female between 76 and 89 years of age with a mean body mass index of 21.9 kg/m(2) (range, 16.8-29.6 kg/m(2)) were used during this study. A single experienced physician sonographer performed ultrasound-guided proximal adductor longus tendon releases on all cadaveric specimens using a cutting wire. Dissection was performed by a second physician to determine the completeness of the tendon transections and to detect injury to adjacent neurovascular or genitourinary structures. RESULTS: All 10 adductor longus tendons were transected. Eight of 10 transections were complete, whereas in 2 transections, >99% of the tendon was transected. There were no injuries to adjacent genitourinary or neurovascular structures. CONCLUSION: Ultrasound-guided adductor tendon release is feasible and safe in a cadaveric model. Further translational research should be performed to determine whether these results can be replicated in the clinical setting. CLINICAL RELEVANCE: Adductor longus tendinopathy frequently requires surgical intervention and prolonged time away from sport. The present study suggests that a selective adductor longus tendon release can be performed with ultrasound guidance. This procedure warrants further translational research to explore its use in clinical practice. SAGE Publications 2019-08-26 /pmc/articles/PMC6710695/ /pubmed/31489333 http://dx.doi.org/10.1177/2325967119866010 Text en © The Author(s) 2019 http://creativecommons.org/licenses/by-nc-nd/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 License (http://www.creativecommons.org/licenses/by-nc-nd/4.0/) which permits non-commercial use, reproduction and distribution of the work as published without adaptation or alteration, without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Article
Boettcher, Brennan J.
Hollman, John H.
Stuart, Michael J.
Finnoff, Jonathan T.
Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title_full Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title_fullStr Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title_full_unstemmed Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title_short Ultrasound-Guided Cutting Wire Release of the Proximal Adductor Longus Tendon: A Feasibility Study
title_sort ultrasound-guided cutting wire release of the proximal adductor longus tendon: a feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6710695/
https://www.ncbi.nlm.nih.gov/pubmed/31489333
http://dx.doi.org/10.1177/2325967119866010
work_keys_str_mv AT boettcherbrennanj ultrasoundguidedcuttingwirereleaseoftheproximaladductorlongustendonafeasibilitystudy
AT hollmanjohnh ultrasoundguidedcuttingwirereleaseoftheproximaladductorlongustendonafeasibilitystudy
AT stuartmichaelj ultrasoundguidedcuttingwirereleaseoftheproximaladductorlongustendonafeasibilitystudy
AT finnoffjonathant ultrasoundguidedcuttingwirereleaseoftheproximaladductorlongustendonafeasibilitystudy