Cargando…
Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans
In the clinical photoacoustic (PA) imaging, ultrasound (US) array transducers are typically used to provide B-mode images in real-time. To form a B-mode image, delay-and-sum (DAS) beamforming algorithm is the most commonly used algorithm because of its ease of implementation. However, this algorithm...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6710719/ https://www.ncbi.nlm.nih.gov/pubmed/31467842 http://dx.doi.org/10.1016/j.pacs.2019.100136 |
_version_ | 1783446394242072576 |
---|---|
author | Jeon, Seungwan Park, Eun-Yeong Choi, Wonseok Managuli, Ravi Lee, Ki jong Kim, Chulhong |
author_facet | Jeon, Seungwan Park, Eun-Yeong Choi, Wonseok Managuli, Ravi Lee, Ki jong Kim, Chulhong |
author_sort | Jeon, Seungwan |
collection | PubMed |
description | In the clinical photoacoustic (PA) imaging, ultrasound (US) array transducers are typically used to provide B-mode images in real-time. To form a B-mode image, delay-and-sum (DAS) beamforming algorithm is the most commonly used algorithm because of its ease of implementation. However, this algorithm suffers from low image resolution and low contrast drawbacks. To address this issue, delay-multiply-and-sum (DMAS) beamforming algorithm has been developed to provide enhanced image quality with higher contrast, and narrower main lobe compared but has limitations on the imaging speed for clinical applications. In this paper, we present an enhanced real-time DMAS algorithm with modified coherence factor (CF) for clinical PA imaging of humans in vivo. Our algorithm improves the lateral resolution and signal-to-noise ratio (SNR) of original DMAS beamformer by suppressing the background noise and side lobes using the coherence of received signals. We optimized the computations of the proposed DMAS with CF (DMAS-CF) to achieve real-time frame rate imaging on a graphics processing unit (GPU). To evaluate the proposed algorithm, we implemented DAS and DMAS with/without CF on a clinical US/PA imaging system and quantitatively assessed their processing speed and image quality. The processing time to reconstruct one B-mode image using DAS, DAS with CF (DAS-CF), DMAS, and DMAS-CF algorithms was 7.5, 7.6, 11.1, and 11.3 ms, respectively, all achieving the real-time imaging frame rate. In terms of the image quality, the proposed DMAS-CF algorithm improved the lateral resolution and SNR by 55.4% and 93.6 dB, respectively, compared to the DAS algorithm in the phantom imaging experiments. We believe the proposed DMAS-CF algorithm and its real-time implementation contributes significantly to the improvement of imaging quality of clinical US/PA imaging system. |
format | Online Article Text |
id | pubmed-6710719 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-67107192019-08-29 Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans Jeon, Seungwan Park, Eun-Yeong Choi, Wonseok Managuli, Ravi Lee, Ki jong Kim, Chulhong Photoacoustics Research Article In the clinical photoacoustic (PA) imaging, ultrasound (US) array transducers are typically used to provide B-mode images in real-time. To form a B-mode image, delay-and-sum (DAS) beamforming algorithm is the most commonly used algorithm because of its ease of implementation. However, this algorithm suffers from low image resolution and low contrast drawbacks. To address this issue, delay-multiply-and-sum (DMAS) beamforming algorithm has been developed to provide enhanced image quality with higher contrast, and narrower main lobe compared but has limitations on the imaging speed for clinical applications. In this paper, we present an enhanced real-time DMAS algorithm with modified coherence factor (CF) for clinical PA imaging of humans in vivo. Our algorithm improves the lateral resolution and signal-to-noise ratio (SNR) of original DMAS beamformer by suppressing the background noise and side lobes using the coherence of received signals. We optimized the computations of the proposed DMAS with CF (DMAS-CF) to achieve real-time frame rate imaging on a graphics processing unit (GPU). To evaluate the proposed algorithm, we implemented DAS and DMAS with/without CF on a clinical US/PA imaging system and quantitatively assessed their processing speed and image quality. The processing time to reconstruct one B-mode image using DAS, DAS with CF (DAS-CF), DMAS, and DMAS-CF algorithms was 7.5, 7.6, 11.1, and 11.3 ms, respectively, all achieving the real-time imaging frame rate. In terms of the image quality, the proposed DMAS-CF algorithm improved the lateral resolution and SNR by 55.4% and 93.6 dB, respectively, compared to the DAS algorithm in the phantom imaging experiments. We believe the proposed DMAS-CF algorithm and its real-time implementation contributes significantly to the improvement of imaging quality of clinical US/PA imaging system. Elsevier 2019-08-09 /pmc/articles/PMC6710719/ /pubmed/31467842 http://dx.doi.org/10.1016/j.pacs.2019.100136 Text en © 2019 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Research Article Jeon, Seungwan Park, Eun-Yeong Choi, Wonseok Managuli, Ravi Lee, Ki jong Kim, Chulhong Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title | Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title_full | Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title_fullStr | Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title_full_unstemmed | Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title_short | Real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
title_sort | real-time delay-multiply-and-sum beamforming with coherence factor for in vivo clinical photoacoustic imaging of humans |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6710719/ https://www.ncbi.nlm.nih.gov/pubmed/31467842 http://dx.doi.org/10.1016/j.pacs.2019.100136 |
work_keys_str_mv | AT jeonseungwan realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans AT parkeunyeong realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans AT choiwonseok realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans AT managuliravi realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans AT leekijong realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans AT kimchulhong realtimedelaymultiplyandsumbeamformingwithcoherencefactorforinvivoclinicalphotoacousticimagingofhumans |