Cargando…
Principles of open source bioinstrumentation applied to the poseidon syringe pump system
The poseidon syringe pump and microscope system is an open source alternative to commercial systems. It costs less than $400 and can be assembled in under an hour using the instructions and source files available at https://pachterlab.github.io/poseidon. We describe the poseidon system and use it to...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6711986/ https://www.ncbi.nlm.nih.gov/pubmed/31455877 http://dx.doi.org/10.1038/s41598-019-48815-9 |
_version_ | 1783446596505042944 |
---|---|
author | Booeshaghi, A. Sina Beltrame, Eduardo da Veiga Bannon, Dylan Gehring, Jase Pachter, Lior |
author_facet | Booeshaghi, A. Sina Beltrame, Eduardo da Veiga Bannon, Dylan Gehring, Jase Pachter, Lior |
author_sort | Booeshaghi, A. Sina |
collection | PubMed |
description | The poseidon syringe pump and microscope system is an open source alternative to commercial systems. It costs less than $400 and can be assembled in under an hour using the instructions and source files available at https://pachterlab.github.io/poseidon. We describe the poseidon system and use it to illustrate design principles that can facilitate the adoption and development of open source bioinstruments. The principles are functionality, robustness, safety, simplicity, modularity, benchmarking, and documentation. |
format | Online Article Text |
id | pubmed-6711986 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-67119862019-09-13 Principles of open source bioinstrumentation applied to the poseidon syringe pump system Booeshaghi, A. Sina Beltrame, Eduardo da Veiga Bannon, Dylan Gehring, Jase Pachter, Lior Sci Rep Article The poseidon syringe pump and microscope system is an open source alternative to commercial systems. It costs less than $400 and can be assembled in under an hour using the instructions and source files available at https://pachterlab.github.io/poseidon. We describe the poseidon system and use it to illustrate design principles that can facilitate the adoption and development of open source bioinstruments. The principles are functionality, robustness, safety, simplicity, modularity, benchmarking, and documentation. Nature Publishing Group UK 2019-08-27 /pmc/articles/PMC6711986/ /pubmed/31455877 http://dx.doi.org/10.1038/s41598-019-48815-9 Text en © The Author(s) 2019 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Booeshaghi, A. Sina Beltrame, Eduardo da Veiga Bannon, Dylan Gehring, Jase Pachter, Lior Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title | Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title_full | Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title_fullStr | Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title_full_unstemmed | Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title_short | Principles of open source bioinstrumentation applied to the poseidon syringe pump system |
title_sort | principles of open source bioinstrumentation applied to the poseidon syringe pump system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6711986/ https://www.ncbi.nlm.nih.gov/pubmed/31455877 http://dx.doi.org/10.1038/s41598-019-48815-9 |
work_keys_str_mv | AT booeshaghiasina principlesofopensourcebioinstrumentationappliedtotheposeidonsyringepumpsystem AT beltrameeduardodaveiga principlesofopensourcebioinstrumentationappliedtotheposeidonsyringepumpsystem AT bannondylan principlesofopensourcebioinstrumentationappliedtotheposeidonsyringepumpsystem AT gehringjase principlesofopensourcebioinstrumentationappliedtotheposeidonsyringepumpsystem AT pachterlior principlesofopensourcebioinstrumentationappliedtotheposeidonsyringepumpsystem |