Cargando…

Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect

BACKGROUND: Diffusion tensor imaging (DTI) is widely used; however, most of the prior studies have resulted in presurgical decreased fractional anisotropy (FA) values in patients with cervical spondylotic myelopathy (CSM). We used ZOOM DTI and could acquire highly accurate FA values during periopera...

Descripción completa

Detalles Bibliográficos
Autores principales: Iwasaki, Motoyuki, Yokohama, Takumi, Oura, Daisuke, Furuya, Shou, Niiya, Yoshimasa, Okuaki, Tomoyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6712487/
https://www.ncbi.nlm.nih.gov/pubmed/31468032
http://dx.doi.org/10.1016/j.wnsx.2019.100056
_version_ 1783446691168387072
author Iwasaki, Motoyuki
Yokohama, Takumi
Oura, Daisuke
Furuya, Shou
Niiya, Yoshimasa
Okuaki, Tomoyuki
author_facet Iwasaki, Motoyuki
Yokohama, Takumi
Oura, Daisuke
Furuya, Shou
Niiya, Yoshimasa
Okuaki, Tomoyuki
author_sort Iwasaki, Motoyuki
collection PubMed
description BACKGROUND: Diffusion tensor imaging (DTI) is widely used; however, most of the prior studies have resulted in presurgical decreased fractional anisotropy (FA) values in patients with cervical spondylotic myelopathy (CSM). We used ZOOM DTI and could acquire highly accurate FA values during perioperative periods, which indicated different insights than preceding studies. The objective of this study was to assess the perioperative FA change in patients with CSM and determine the prognostic factor. METHODS: Twenty-eight patients with CSM and healthy control subjects were enrolled in this study. Twenty patients (71%) had intracordal high intensity before surgery. All patients underwent decompressive surgery. ZOOM DTI and the Japanese Orthopaedic Association (JOA) assessment were performed before and after surgery. The region of interest was manually contoured to omit the surrounding cerebrospinal fluid. The axial plane of the most stenotic cervical level was assessed. RESULTS: FA values before surgery and at 1 week after surgery, and FA values at 1 week after surgery and at 6 months after surgery differed significantly as determined. The FA values of patients with intracordal high intensity significantly decreased after surgery and significantly increased from 1 week to 6 months, whereas those of patients without intracordal high intensity did not significantly change. JOA scores at 6 months after surgery (13.1) improved significantly compared with JOA scores before surgery (10.8). Only FA values at 1 week after surgery had a significant positive relationship with JOA scores presurgery and at 6 months after surgery. CONCLUSIONS: The presurgical FA value in patients with CSM did not differ from that of normal control subjects, but significantly decreased after surgery, and significantly increased 6 months after surgery. We concluded that the postsurgical FA value approximates the proper state of the damaged cord and the presurgical FA value includes a masked effect as an aligned fiber effect because of compression by degenerative construction. Only the FA value at 1 week had a significant positive relationship with the JOA score presugery and at 6 months, which established that the postsurgical FA value may be a more accurate prognostic factor than the presurgical FA value.
format Online
Article
Text
id pubmed-6712487
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-67124872019-08-29 Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect Iwasaki, Motoyuki Yokohama, Takumi Oura, Daisuke Furuya, Shou Niiya, Yoshimasa Okuaki, Tomoyuki World Neurosurg X Original Article BACKGROUND: Diffusion tensor imaging (DTI) is widely used; however, most of the prior studies have resulted in presurgical decreased fractional anisotropy (FA) values in patients with cervical spondylotic myelopathy (CSM). We used ZOOM DTI and could acquire highly accurate FA values during perioperative periods, which indicated different insights than preceding studies. The objective of this study was to assess the perioperative FA change in patients with CSM and determine the prognostic factor. METHODS: Twenty-eight patients with CSM and healthy control subjects were enrolled in this study. Twenty patients (71%) had intracordal high intensity before surgery. All patients underwent decompressive surgery. ZOOM DTI and the Japanese Orthopaedic Association (JOA) assessment were performed before and after surgery. The region of interest was manually contoured to omit the surrounding cerebrospinal fluid. The axial plane of the most stenotic cervical level was assessed. RESULTS: FA values before surgery and at 1 week after surgery, and FA values at 1 week after surgery and at 6 months after surgery differed significantly as determined. The FA values of patients with intracordal high intensity significantly decreased after surgery and significantly increased from 1 week to 6 months, whereas those of patients without intracordal high intensity did not significantly change. JOA scores at 6 months after surgery (13.1) improved significantly compared with JOA scores before surgery (10.8). Only FA values at 1 week after surgery had a significant positive relationship with JOA scores presurgery and at 6 months after surgery. CONCLUSIONS: The presurgical FA value in patients with CSM did not differ from that of normal control subjects, but significantly decreased after surgery, and significantly increased 6 months after surgery. We concluded that the postsurgical FA value approximates the proper state of the damaged cord and the presurgical FA value includes a masked effect as an aligned fiber effect because of compression by degenerative construction. Only the FA value at 1 week had a significant positive relationship with the JOA score presugery and at 6 months, which established that the postsurgical FA value may be a more accurate prognostic factor than the presurgical FA value. Elsevier 2019-07-26 /pmc/articles/PMC6712487/ /pubmed/31468032 http://dx.doi.org/10.1016/j.wnsx.2019.100056 Text en © 2019 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Iwasaki, Motoyuki
Yokohama, Takumi
Oura, Daisuke
Furuya, Shou
Niiya, Yoshimasa
Okuaki, Tomoyuki
Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title_full Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title_fullStr Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title_full_unstemmed Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title_short Decreased Value of Highly Accurate Fractional Anisotropy Using 3-Tesla ZOOM Diffusion Tensor Imaging After Decompressive Surgery in Patients with Cervical Spondylotic Myelopathy: Aligned Fibers Effect
title_sort decreased value of highly accurate fractional anisotropy using 3-tesla zoom diffusion tensor imaging after decompressive surgery in patients with cervical spondylotic myelopathy: aligned fibers effect
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6712487/
https://www.ncbi.nlm.nih.gov/pubmed/31468032
http://dx.doi.org/10.1016/j.wnsx.2019.100056
work_keys_str_mv AT iwasakimotoyuki decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect
AT yokohamatakumi decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect
AT ouradaisuke decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect
AT furuyashou decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect
AT niiyayoshimasa decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect
AT okuakitomoyuki decreasedvalueofhighlyaccuratefractionalanisotropyusing3teslazoomdiffusiontensorimagingafterdecompressivesurgeryinpatientswithcervicalspondyloticmyelopathyalignedfiberseffect