Cargando…

Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey

BACKGROUND: Frequency of insulin pen use, despite its higher costs, is increasing to substitute the traditional use of insulin vials. This study aims to report insulin pen use frequency and its associated factors among participants of the STEPS survey 2016 in Iran, which was conducted based on the W...

Descripción completa

Detalles Bibliográficos
Autores principales: Ebrahimi, Hedyeh, Pishgar, Farhad, Yoosefi, Moein, Moradi, Sedighe, Rezaei, Nazila, Djalalinia, Shirin, Modirian, Mitra, Peykari, Niloofar, Naderimagham, Shohreh, Haghshenas, Rosa, Rahimi, Saral, Jamshidi, Hamidreza, Esteghamati, Alireza, Larijani, Bagher, Farzadfar, Farshad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713357/
https://www.ncbi.nlm.nih.gov/pubmed/31461470
http://dx.doi.org/10.1371/journal.pone.0221462
_version_ 1783446859824496640
author Ebrahimi, Hedyeh
Pishgar, Farhad
Yoosefi, Moein
Moradi, Sedighe
Rezaei, Nazila
Djalalinia, Shirin
Modirian, Mitra
Peykari, Niloofar
Naderimagham, Shohreh
Haghshenas, Rosa
Rahimi, Saral
Jamshidi, Hamidreza
Esteghamati, Alireza
Larijani, Bagher
Farzadfar, Farshad
author_facet Ebrahimi, Hedyeh
Pishgar, Farhad
Yoosefi, Moein
Moradi, Sedighe
Rezaei, Nazila
Djalalinia, Shirin
Modirian, Mitra
Peykari, Niloofar
Naderimagham, Shohreh
Haghshenas, Rosa
Rahimi, Saral
Jamshidi, Hamidreza
Esteghamati, Alireza
Larijani, Bagher
Farzadfar, Farshad
author_sort Ebrahimi, Hedyeh
collection PubMed
description BACKGROUND: Frequency of insulin pen use, despite its higher costs, is increasing to substitute the traditional use of insulin vials. This study aims to report insulin pen use frequency and its associated factors among participants of the STEPS survey 2016 in Iran, which was conducted based on the World Health Organization (WHO) STEPS methodology. METHODS: In this cross-sectional study, 19,503 (mean age of 46.03±0.13) out of 30,541 participants of the Iran STEPS survey were included (Inclusion criteria: aged >25 years old and availability of their demographic, clinical, and laboratory results for serum glucose, HbA1c, and lipid profile). Clinical and demographic characteristics, a frequency of use of each diabetes mellitus treatment type, and the association of insulin pen use with health outcomes are reported using descriptive analysis and propensity score modeling. RESULTS: There were 1,999(10.85%) individuals diagnosed with diabetes in the population, while 1,160(56.87%) cases were taking antihyperglycemic treatments. In this subset, 240(21.14%) individuals administered insulin with or without using oral agents at the same time. 52.28% of participants who were under insulin therapy used insulin pens. None of the socioeconomic determinants, including gender (p-value = 0.11), type of residential areas (p-value = 0.52), years of schooling (p-value = 0.27), wealth index (p-value = 0.19), marital status (p-value = 0.37), and insurance types (p-value = 0.72) were significantly different among groups using insulin pens and insulin vials. Moreover, in the propensity score modeling, pen usage was not associated with a lower heart attack and ischemic stroke histories, systolic blood pressure, serum lipid profile, blood glucose, or HbA1c levels. CONCLUSION: Results showed that the use of the higher-costing insulin pens compared to traditional vials and syringes is not associated with improved glycemic control and better lipid profile in our sample. Future studies are needed to confirm these findings and to compare other aspects of insulin pen use, including adherence to treatment and cost-effectiveness.
format Online
Article
Text
id pubmed-6713357
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-67133572019-09-04 Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey Ebrahimi, Hedyeh Pishgar, Farhad Yoosefi, Moein Moradi, Sedighe Rezaei, Nazila Djalalinia, Shirin Modirian, Mitra Peykari, Niloofar Naderimagham, Shohreh Haghshenas, Rosa Rahimi, Saral Jamshidi, Hamidreza Esteghamati, Alireza Larijani, Bagher Farzadfar, Farshad PLoS One Research Article BACKGROUND: Frequency of insulin pen use, despite its higher costs, is increasing to substitute the traditional use of insulin vials. This study aims to report insulin pen use frequency and its associated factors among participants of the STEPS survey 2016 in Iran, which was conducted based on the World Health Organization (WHO) STEPS methodology. METHODS: In this cross-sectional study, 19,503 (mean age of 46.03±0.13) out of 30,541 participants of the Iran STEPS survey were included (Inclusion criteria: aged >25 years old and availability of their demographic, clinical, and laboratory results for serum glucose, HbA1c, and lipid profile). Clinical and demographic characteristics, a frequency of use of each diabetes mellitus treatment type, and the association of insulin pen use with health outcomes are reported using descriptive analysis and propensity score modeling. RESULTS: There were 1,999(10.85%) individuals diagnosed with diabetes in the population, while 1,160(56.87%) cases were taking antihyperglycemic treatments. In this subset, 240(21.14%) individuals administered insulin with or without using oral agents at the same time. 52.28% of participants who were under insulin therapy used insulin pens. None of the socioeconomic determinants, including gender (p-value = 0.11), type of residential areas (p-value = 0.52), years of schooling (p-value = 0.27), wealth index (p-value = 0.19), marital status (p-value = 0.37), and insurance types (p-value = 0.72) were significantly different among groups using insulin pens and insulin vials. Moreover, in the propensity score modeling, pen usage was not associated with a lower heart attack and ischemic stroke histories, systolic blood pressure, serum lipid profile, blood glucose, or HbA1c levels. CONCLUSION: Results showed that the use of the higher-costing insulin pens compared to traditional vials and syringes is not associated with improved glycemic control and better lipid profile in our sample. Future studies are needed to confirm these findings and to compare other aspects of insulin pen use, including adherence to treatment and cost-effectiveness. Public Library of Science 2019-08-28 /pmc/articles/PMC6713357/ /pubmed/31461470 http://dx.doi.org/10.1371/journal.pone.0221462 Text en © 2019 Ebrahimi et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Ebrahimi, Hedyeh
Pishgar, Farhad
Yoosefi, Moein
Moradi, Sedighe
Rezaei, Nazila
Djalalinia, Shirin
Modirian, Mitra
Peykari, Niloofar
Naderimagham, Shohreh
Haghshenas, Rosa
Rahimi, Saral
Jamshidi, Hamidreza
Esteghamati, Alireza
Larijani, Bagher
Farzadfar, Farshad
Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title_full Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title_fullStr Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title_full_unstemmed Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title_short Insulin pen use and diabetes treatment goals: A study from Iran STEPS 2016 survey
title_sort insulin pen use and diabetes treatment goals: a study from iran steps 2016 survey
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713357/
https://www.ncbi.nlm.nih.gov/pubmed/31461470
http://dx.doi.org/10.1371/journal.pone.0221462
work_keys_str_mv AT ebrahimihedyeh insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT pishgarfarhad insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT yoosefimoein insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT moradisedighe insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT rezaeinazila insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT djalaliniashirin insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT modirianmitra insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT peykariniloofar insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT naderimaghamshohreh insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT haghshenasrosa insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT rahimisaral insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT jamshidihamidreza insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT esteghamatialireza insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT larijanibagher insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey
AT farzadfarfarshad insulinpenuseanddiabetestreatmentgoalsastudyfromiransteps2016survey