Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay

BACKGROUND: The interferon-gamma (IFN-γ) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Jin Ju, Park, Younhee, Choi, Dasom, Kim, Hyon-Suk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society for Laboratory Medicine 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713648/
https://www.ncbi.nlm.nih.gov/pubmed/31432637
http://dx.doi.org/10.3343/alm.2020.40.1.33
_version_ 1783446898386927616
author Kim, Jin Ju
Park, Younhee
Choi, Dasom
Kim, Hyon-Suk
author_facet Kim, Jin Ju
Park, Younhee
Choi, Dasom
Kim, Hyon-Suk
author_sort Kim, Jin Ju
collection PubMed
description BACKGROUND: The interferon-gamma (IFN-γ) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay. METHODS: Repeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-γ standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed. RESULTS: Repeatability and reproducibility were 4.86–7.00% and 6.36–7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-γ values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI. CONCLUSIONS: CLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT.
format Online
Article
Text
id pubmed-6713648
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Korean Society for Laboratory Medicine
record_format MEDLINE/PubMed
spelling pubmed-67136482020-01-01 Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay Kim, Jin Ju Park, Younhee Choi, Dasom Kim, Hyon-Suk Ann Lab Med Original Article BACKGROUND: The interferon-gamma (IFN-γ) releasing assay (IGRA) is widely used for latent tuberculosis infection (LTBI) diagnosis. We evaluated the analytical performance of a new automated chemiluminescent immunoanalyzer-based IGRA (CLIA-IGRA), AdvanSure I3 (LG Life Sciences, Seoul, Korea) and compared it with that of the QuantiFERON-TB Gold In-Tube (QFT-GIT) assay. METHODS: Repeatability and reproducibility were evaluated at four levels. Detection capability, including limit of blank (LoB), limit of detection (LoD), and limit of quantification (LoQ), was evaluated using IFN-γ standard material (National Institute for Biological Standards and Control code: 87/586). Agreement between the results of two assays was evaluated using 341 blood samples from healthcare workers and patients at a tertiary care hospital. To determine the cut-off value of CLIA-IGRA for diagnosing LTBI, the ROC curve was analyzed. RESULTS: Repeatability and reproducibility were 4.86–7.00% and 6.36–7.88% CV, respectively. LoB, LoD, and LoQ were 0.022, 0.077, and 0.249 IU/mL, respectively. IFN-γ values between CLIA-IGRA and QFT-GIT showed a strong correlation within the analytical measurable range of both assays, especially when the value was low. Qualitative comparison of the two assays yielded a 99.1% overall agreement (kappa coefficient=0.98). A cut-off value of 0.35 IU/mL was appropriate for diagnosing LTBI. CONCLUSIONS: CLIA-IGRA is a reliable assay for LTBI diagnosis, with performance similar to that of QFT-GIT. The Korean Society for Laboratory Medicine 2020-01 2019-08-19 /pmc/articles/PMC6713648/ /pubmed/31432637 http://dx.doi.org/10.3343/alm.2020.40.1.33 Text en © The Korean Society for Laboratory Medicine http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Jin Ju
Park, Younhee
Choi, Dasom
Kim, Hyon-Suk
Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title_full Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title_fullStr Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title_full_unstemmed Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title_short Performance Evaluation of a New Automated Chemiluminescent Immunoanalyzer-Based Interferon-Gamma Releasing Assay AdvanSure I3 in Comparison With the QuantiFERON-TB Gold In-Tube Assay
title_sort performance evaluation of a new automated chemiluminescent immunoanalyzer-based interferon-gamma releasing assay advansure i3 in comparison with the quantiferon-tb gold in-tube assay
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713648/
https://www.ncbi.nlm.nih.gov/pubmed/31432637
http://dx.doi.org/10.3343/alm.2020.40.1.33
work_keys_str_mv AT kimjinju performanceevaluationofanewautomatedchemiluminescentimmunoanalyzerbasedinterferongammareleasingassayadvansurei3incomparisonwiththequantiferontbgoldintubeassay
AT parkyounhee performanceevaluationofanewautomatedchemiluminescentimmunoanalyzerbasedinterferongammareleasingassayadvansurei3incomparisonwiththequantiferontbgoldintubeassay
AT choidasom performanceevaluationofanewautomatedchemiluminescentimmunoanalyzerbasedinterferongammareleasingassayadvansurei3incomparisonwiththequantiferontbgoldintubeassay
AT kimhyonsuk performanceevaluationofanewautomatedchemiluminescentimmunoanalyzerbasedinterferongammareleasingassayadvansurei3incomparisonwiththequantiferontbgoldintubeassay