Cargando…
Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct
Hamstring strains account for 25% to 30% of all muscle strains and are an exceedingly common injury in the athletic population. Although proximal hamstring avulsion injuries occur less commonly than strains at the myotendinous junction, they are more severe and debilitating. Proximal hamstring avuls...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713840/ https://www.ncbi.nlm.nih.gov/pubmed/31467836 http://dx.doi.org/10.1016/j.eats.2019.02.013 |
_version_ | 1783446943763005440 |
---|---|
author | Mehta, Nabil Alter, Thomas Beck, Edward C. Cancienne, Jourdan M. Bressler, Leah R. Liu, Joseph N. Nho, Shane J. |
author_facet | Mehta, Nabil Alter, Thomas Beck, Edward C. Cancienne, Jourdan M. Bressler, Leah R. Liu, Joseph N. Nho, Shane J. |
author_sort | Mehta, Nabil |
collection | PubMed |
description | Hamstring strains account for 25% to 30% of all muscle strains and are an exceedingly common injury in the athletic population. Although proximal hamstring avulsion injuries occur less commonly than strains at the myotendinous junction, they are more severe and debilitating. Proximal hamstring avulsions do not respond well to conservative treatment and are more likely to require surgical intervention. Surgical repair of proximal hamstring avulsions is indicated when the injury fails to respond to conservative treatment, in cases of osseous avulsion with retraction, and in cases of tearing of all 3 hamstring tendons. Endoscopic repair of proximal hamstring avulsions is a promising technique to repair these injuries while reducing morbidity. We describe our technique for endoscopic proximal hamstring repair, which uses a double-row suture bridge construct to reattach the tendons to the ischial tuberosity. |
format | Online Article Text |
id | pubmed-6713840 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-67138402019-08-29 Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct Mehta, Nabil Alter, Thomas Beck, Edward C. Cancienne, Jourdan M. Bressler, Leah R. Liu, Joseph N. Nho, Shane J. Arthrosc Tech Technical Note Hamstring strains account for 25% to 30% of all muscle strains and are an exceedingly common injury in the athletic population. Although proximal hamstring avulsion injuries occur less commonly than strains at the myotendinous junction, they are more severe and debilitating. Proximal hamstring avulsions do not respond well to conservative treatment and are more likely to require surgical intervention. Surgical repair of proximal hamstring avulsions is indicated when the injury fails to respond to conservative treatment, in cases of osseous avulsion with retraction, and in cases of tearing of all 3 hamstring tendons. Endoscopic repair of proximal hamstring avulsions is a promising technique to repair these injuries while reducing morbidity. We describe our technique for endoscopic proximal hamstring repair, which uses a double-row suture bridge construct to reattach the tendons to the ischial tuberosity. Elsevier 2019-06-06 /pmc/articles/PMC6713840/ /pubmed/31467836 http://dx.doi.org/10.1016/j.eats.2019.02.013 Text en © 2019 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Mehta, Nabil Alter, Thomas Beck, Edward C. Cancienne, Jourdan M. Bressler, Leah R. Liu, Joseph N. Nho, Shane J. Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title | Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title_full | Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title_fullStr | Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title_full_unstemmed | Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title_short | Endoscopic Repair of Proximal Hamstring Tear With Double-Row Suture Bridge Construct |
title_sort | endoscopic repair of proximal hamstring tear with double-row suture bridge construct |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713840/ https://www.ncbi.nlm.nih.gov/pubmed/31467836 http://dx.doi.org/10.1016/j.eats.2019.02.013 |
work_keys_str_mv | AT mehtanabil endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT alterthomas endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT beckedwardc endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT canciennejourdanm endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT bresslerleahr endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT liujosephn endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct AT nhoshanej endoscopicrepairofproximalhamstringtearwithdoublerowsuturebridgeconstruct |