Cargando…

Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort

BACKGROUND: This study aimed to compare the distribution of Prostate Imaging Reporting and Data System (PI-RADS) score and the diagnostic accuracy of magnetic resonance imaging (MRI)–targeted biopsy and systematic biopsy between a Chinese and a Dutch cohort. MATERIALS AND METHODS: Our study includes...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Kai, Chen, Rui, Alberts, Arnout R., Zhu, Gang, Sun, Yinghao, Roobol, Monique J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Asian Pacific Prostate Society 2019
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713844/
https://www.ncbi.nlm.nih.gov/pubmed/31485433
http://dx.doi.org/10.1016/j.prnil.2018.10.001
_version_ 1783446944665829376
author Zhang, Kai
Chen, Rui
Alberts, Arnout R.
Zhu, Gang
Sun, Yinghao
Roobol, Monique J.
author_facet Zhang, Kai
Chen, Rui
Alberts, Arnout R.
Zhu, Gang
Sun, Yinghao
Roobol, Monique J.
author_sort Zhang, Kai
collection PubMed
description BACKGROUND: This study aimed to compare the distribution of Prostate Imaging Reporting and Data System (PI-RADS) score and the diagnostic accuracy of magnetic resonance imaging (MRI)–targeted biopsy and systematic biopsy between a Chinese and a Dutch cohort. MATERIALS AND METHODS: Our study includes 316 men from Shanghai Changhai Hospital, China, and 266 men from the Erasmus University Medical Center, Rotterdam, the Netherlands. All men had a suspicion for prostate cancer (PCa) and were offered an multiparametric MRI (mpMRI) scan. RESULTS: The distribution of the PI-RADS score was different between the two cohorts (P = 0.008). In the Chinese cohort of PI-RADS ≥3, the detection rate for high-grade PCa (Gleason ≥7) was 37.3% by systematic biopsy and 35.5% by MRI-targeted biopsy. The sensitivity of systematic biopsy was 0.80 for PCa and 0.75 for high-grade PCa. MRI-targeted biopsy achieved slightly higher sensitivity for PCa (0.82) and high-grade PCa (0.76). In the Dutch cohort of PI-RADS ≥3, the high-grade PCa detection rate was 44.4% and 54.5% for systematic biopsy and MRI-targeted biopsy. The sensitivity of systematic biopsy was 0.93 for PCa and 0.81 for high-grade PCa. By MRI-targeted biopsy, the sensitivity was 0.85 for PCa and 0.97 for high-grade PCa. CONCLUSIONS: The distribution of the PI-RADS score was different with more PI-RADS 4/5 in the Chinese cohort. Applying a PI-RADS ≥3 cutoff resulted in a favorable overall sensitivity. MRI-targeted biopsy showed a higher sensitivity in the detection of high-grade PCa than systematic biopsy. The sensitivity of MRI-targeted biopsy and systematic biopsy for both PCa and high-grade PCa in the Dutch cohort was superior to those in the Chinese cohort.
format Online
Article
Text
id pubmed-6713844
institution National Center for Biotechnology Information
language English
publishDate 2019
publisher Asian Pacific Prostate Society
record_format MEDLINE/PubMed
spelling pubmed-67138442019-09-04 Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort Zhang, Kai Chen, Rui Alberts, Arnout R. Zhu, Gang Sun, Yinghao Roobol, Monique J. Prostate Int Original Article BACKGROUND: This study aimed to compare the distribution of Prostate Imaging Reporting and Data System (PI-RADS) score and the diagnostic accuracy of magnetic resonance imaging (MRI)–targeted biopsy and systematic biopsy between a Chinese and a Dutch cohort. MATERIALS AND METHODS: Our study includes 316 men from Shanghai Changhai Hospital, China, and 266 men from the Erasmus University Medical Center, Rotterdam, the Netherlands. All men had a suspicion for prostate cancer (PCa) and were offered an multiparametric MRI (mpMRI) scan. RESULTS: The distribution of the PI-RADS score was different between the two cohorts (P = 0.008). In the Chinese cohort of PI-RADS ≥3, the detection rate for high-grade PCa (Gleason ≥7) was 37.3% by systematic biopsy and 35.5% by MRI-targeted biopsy. The sensitivity of systematic biopsy was 0.80 for PCa and 0.75 for high-grade PCa. MRI-targeted biopsy achieved slightly higher sensitivity for PCa (0.82) and high-grade PCa (0.76). In the Dutch cohort of PI-RADS ≥3, the high-grade PCa detection rate was 44.4% and 54.5% for systematic biopsy and MRI-targeted biopsy. The sensitivity of systematic biopsy was 0.93 for PCa and 0.81 for high-grade PCa. By MRI-targeted biopsy, the sensitivity was 0.85 for PCa and 0.97 for high-grade PCa. CONCLUSIONS: The distribution of the PI-RADS score was different with more PI-RADS 4/5 in the Chinese cohort. Applying a PI-RADS ≥3 cutoff resulted in a favorable overall sensitivity. MRI-targeted biopsy showed a higher sensitivity in the detection of high-grade PCa than systematic biopsy. The sensitivity of MRI-targeted biopsy and systematic biopsy for both PCa and high-grade PCa in the Dutch cohort was superior to those in the Chinese cohort. Asian Pacific Prostate Society 2019-09 2018-10-22 /pmc/articles/PMC6713844/ /pubmed/31485433 http://dx.doi.org/10.1016/j.prnil.2018.10.001 Text en © 2018 Asian Pacific Prostate Society, Published by Elsevier Korea LLC. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Zhang, Kai
Chen, Rui
Alberts, Arnout R.
Zhu, Gang
Sun, Yinghao
Roobol, Monique J.
Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title_full Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title_fullStr Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title_full_unstemmed Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title_short Distribution of Prostate Imaging Reporting and Data System score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an Asian and European cohort
title_sort distribution of prostate imaging reporting and data system score and diagnostic accuracy of magnetic resonance imaging–targeted biopsy: comparison of an asian and european cohort
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6713844/
https://www.ncbi.nlm.nih.gov/pubmed/31485433
http://dx.doi.org/10.1016/j.prnil.2018.10.001
work_keys_str_mv AT zhangkai distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort
AT chenrui distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort
AT albertsarnoutr distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort
AT zhugang distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort
AT sunyinghao distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort
AT roobolmoniquej distributionofprostateimagingreportinganddatasystemscoreanddiagnosticaccuracyofmagneticresonanceimagingtargetedbiopsycomparisonofanasianandeuropeancohort