Cargando…
Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom
BACKGROUND: Dual-layer spectral detector CT (SDCT) may provide several theoretical advantages over pre-existing DECT approaches in terms of adjustment-free sampling number and dose modulation, beam hardening correction, and production spectral images by post-processing. In addition, by adopting nois...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714289/ https://www.ncbi.nlm.nih.gov/pubmed/31462212 http://dx.doi.org/10.1186/s12880-019-0367-8 |
_version_ | 1783447033898598400 |
---|---|
author | Kang, Hyo-Jin Lee, Jeong Min Lee, Sang Min Yang, Hyun Kyung Kim, Ri Hyeon Nam, Ju Gang Karnawat, Aruna Han, Joon Koo |
author_facet | Kang, Hyo-Jin Lee, Jeong Min Lee, Sang Min Yang, Hyun Kyung Kim, Ri Hyeon Nam, Ju Gang Karnawat, Aruna Han, Joon Koo |
author_sort | Kang, Hyo-Jin |
collection | PubMed |
description | BACKGROUND: Dual-layer spectral detector CT (SDCT) may provide several theoretical advantages over pre-existing DECT approaches in terms of adjustment-free sampling number and dose modulation, beam hardening correction, and production spectral images by post-processing. In addition, by adopting noise reduction algorithm, high contrast resolution was expected even in low keV level. We surmised that this improvement would be beneficial to obese people. Therefore, our aim of study is to compare image quality of virtual monochromatic spectral images (VMI) and polychromatic images reconstructed from SDCT with different body size and radiation dose using anthropomorphic liver phantom. METHODS: One small and one large size of body phantoms, each containing eight (four high- and four low-contrast) simulated focal liver lesions (FLLs) were scanned by SDCT (at 120 kVp) using different Dose Right Indexes (DRIs). VMI were reconstructed from spectral base images from 40 keV to 200 keV. Hybrid iterative reconstruction (iDose(4)) was used for polychromatic image reconstruction. Image noise and contrast to noise ratio (CNR) were compared. Five radiologists independently rated lesion conspicuity, diagnostic acceptability and subjective noise level in every image sets, and determined optimal keV level in VMI. RESULTS: Compare with conventional polychromatic images, VMI showed superior CNR at low keV level regardless of phantom size at every examined DRIs (Ps < 0.05). As body size increased, VMI had more gradual CNR decrease and noise increase than conventional polychromatic images. For low contrast FLLs in large phantom, lesion conspicuities at low radiation dose levels (DRI 16 and 19) were significantly increased in VMI (Ps < 0.05). Subjective image noise and diagnostic acceptabilities were significantly improved at VMI in both phantom size. CONCLUSIONS: VMI of dual-layer spectral detector CT with noise reduction algorithm provides improved CNR, noise reduction, and better subjective image quality in imaging of obese simulated liver phantom compared with polychromatic images. This may hold promise for improving detection of liver lesions and improved imaging of obese patients. |
format | Online Article Text |
id | pubmed-6714289 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-67142892019-09-04 Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom Kang, Hyo-Jin Lee, Jeong Min Lee, Sang Min Yang, Hyun Kyung Kim, Ri Hyeon Nam, Ju Gang Karnawat, Aruna Han, Joon Koo BMC Med Imaging Research Article BACKGROUND: Dual-layer spectral detector CT (SDCT) may provide several theoretical advantages over pre-existing DECT approaches in terms of adjustment-free sampling number and dose modulation, beam hardening correction, and production spectral images by post-processing. In addition, by adopting noise reduction algorithm, high contrast resolution was expected even in low keV level. We surmised that this improvement would be beneficial to obese people. Therefore, our aim of study is to compare image quality of virtual monochromatic spectral images (VMI) and polychromatic images reconstructed from SDCT with different body size and radiation dose using anthropomorphic liver phantom. METHODS: One small and one large size of body phantoms, each containing eight (four high- and four low-contrast) simulated focal liver lesions (FLLs) were scanned by SDCT (at 120 kVp) using different Dose Right Indexes (DRIs). VMI were reconstructed from spectral base images from 40 keV to 200 keV. Hybrid iterative reconstruction (iDose(4)) was used for polychromatic image reconstruction. Image noise and contrast to noise ratio (CNR) were compared. Five radiologists independently rated lesion conspicuity, diagnostic acceptability and subjective noise level in every image sets, and determined optimal keV level in VMI. RESULTS: Compare with conventional polychromatic images, VMI showed superior CNR at low keV level regardless of phantom size at every examined DRIs (Ps < 0.05). As body size increased, VMI had more gradual CNR decrease and noise increase than conventional polychromatic images. For low contrast FLLs in large phantom, lesion conspicuities at low radiation dose levels (DRI 16 and 19) were significantly increased in VMI (Ps < 0.05). Subjective image noise and diagnostic acceptabilities were significantly improved at VMI in both phantom size. CONCLUSIONS: VMI of dual-layer spectral detector CT with noise reduction algorithm provides improved CNR, noise reduction, and better subjective image quality in imaging of obese simulated liver phantom compared with polychromatic images. This may hold promise for improving detection of liver lesions and improved imaging of obese patients. BioMed Central 2019-08-28 /pmc/articles/PMC6714289/ /pubmed/31462212 http://dx.doi.org/10.1186/s12880-019-0367-8 Text en © The Author(s). 2019 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kang, Hyo-Jin Lee, Jeong Min Lee, Sang Min Yang, Hyun Kyung Kim, Ri Hyeon Nam, Ju Gang Karnawat, Aruna Han, Joon Koo Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title | Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title_full | Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title_fullStr | Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title_full_unstemmed | Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title_short | Value of virtual monochromatic spectral image of dual-layer spectral detector CT with noise reduction algorithm for image quality improvement in obese simulated body phantom |
title_sort | value of virtual monochromatic spectral image of dual-layer spectral detector ct with noise reduction algorithm for image quality improvement in obese simulated body phantom |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714289/ https://www.ncbi.nlm.nih.gov/pubmed/31462212 http://dx.doi.org/10.1186/s12880-019-0367-8 |
work_keys_str_mv | AT kanghyojin valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT leejeongmin valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT leesangmin valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT yanghyunkyung valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT kimrihyeon valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT namjugang valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT karnawataruna valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom AT hanjoonkoo valueofvirtualmonochromaticspectralimageofduallayerspectraldetectorctwithnoisereductionalgorithmforimagequalityimprovementinobesesimulatedbodyphantom |