Cargando…
High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study
BACKGROUND AND OBJECTIVE: EUS-guided fine-needle biopsy has become the standard for tissue sampling. A new 20G ProCore™ (PC) needle has been developed to overcome the limitations of tissue acquisition of the smaller needles (22G, 25G) and the rigidity of the larger one (19G). The aim of this study i...
Autores principales: | , , , , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2019
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714486/ https://www.ncbi.nlm.nih.gov/pubmed/31115386 http://dx.doi.org/10.4103/eus.eus_14_19 |
_version_ | 1783447080325349376 |
---|---|
author | Fabbri, Carlo Fornelli, Adele Fuccio, Lorenzo Giovanelli, Silvia Tarantino, Ilaria Antonini, Filippo Liotta, Rosa Frazzoni, Leonardo Gusella, Paolo La Marca, Marina Barresi, Luca Macarri, Giampiero Traina, Mario De Biase, Dario Fiorino, Siro Jovine, Elio Larghi, Alberto Cennamo, Vincenzo |
author_facet | Fabbri, Carlo Fornelli, Adele Fuccio, Lorenzo Giovanelli, Silvia Tarantino, Ilaria Antonini, Filippo Liotta, Rosa Frazzoni, Leonardo Gusella, Paolo La Marca, Marina Barresi, Luca Macarri, Giampiero Traina, Mario De Biase, Dario Fiorino, Siro Jovine, Elio Larghi, Alberto Cennamo, Vincenzo |
author_sort | Fabbri, Carlo |
collection | PubMed |
description | BACKGROUND AND OBJECTIVE: EUS-guided fine-needle biopsy has become the standard for tissue sampling. A new 20G ProCore™ (PC) needle has been developed to overcome the limitations of tissue acquisition of the smaller needles (22G, 25G) and the rigidity of the larger one (19G). The aim of this study is to assess the performance of the 20G PC needle. MATERIALS AND METHODS: Patients who underwent EUS-guided tissue acquisition with the 20G PC needle of pancreatic and extra-pancreatic mass lesions were retrospectively identified at three Italian centers (Bologna, Fermo, and Palermo). Diagnostic adequacy, accuracy, and tissue core acquisition were the outcome measures. All the cases were performed without rapid on-site evaluation. RESULTS: A total of 384 patients with pancreatic (62.2%) and extra-pancreatic lesions were included in the study. For pancreatic lesions, adequacy, accuracy, sensitivity, and specificity were 92.4%, 91.5%, 90.8%, and 100%, respectively, with a number needed to misdiagnose (NNM) of 11.8. The tissue core was obtained in 72% of cases. Transduodenal approach was performed in 150 pancreatic lesions; adequacy, accuracy, and tissue core acquisition were 88.7%, 90%, and 66%, respectively (NNM 10). For extrapancreatic lesions, adequacy, accuracy, sensitivity, specificity, and tissue core sampling were 95.3%, 95.3%, 92.6%, 100%, and 84.5% (NNM 21.3). CONCLUSIONS: The 20G PC needle showed high diagnostic adequacy and accuracy, regardless the access route. |
format | Online Article Text |
id | pubmed-6714486 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2019 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-67144862019-09-12 High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study Fabbri, Carlo Fornelli, Adele Fuccio, Lorenzo Giovanelli, Silvia Tarantino, Ilaria Antonini, Filippo Liotta, Rosa Frazzoni, Leonardo Gusella, Paolo La Marca, Marina Barresi, Luca Macarri, Giampiero Traina, Mario De Biase, Dario Fiorino, Siro Jovine, Elio Larghi, Alberto Cennamo, Vincenzo Endosc Ultrasound Original Article BACKGROUND AND OBJECTIVE: EUS-guided fine-needle biopsy has become the standard for tissue sampling. A new 20G ProCore™ (PC) needle has been developed to overcome the limitations of tissue acquisition of the smaller needles (22G, 25G) and the rigidity of the larger one (19G). The aim of this study is to assess the performance of the 20G PC needle. MATERIALS AND METHODS: Patients who underwent EUS-guided tissue acquisition with the 20G PC needle of pancreatic and extra-pancreatic mass lesions were retrospectively identified at three Italian centers (Bologna, Fermo, and Palermo). Diagnostic adequacy, accuracy, and tissue core acquisition were the outcome measures. All the cases were performed without rapid on-site evaluation. RESULTS: A total of 384 patients with pancreatic (62.2%) and extra-pancreatic lesions were included in the study. For pancreatic lesions, adequacy, accuracy, sensitivity, and specificity were 92.4%, 91.5%, 90.8%, and 100%, respectively, with a number needed to misdiagnose (NNM) of 11.8. The tissue core was obtained in 72% of cases. Transduodenal approach was performed in 150 pancreatic lesions; adequacy, accuracy, and tissue core acquisition were 88.7%, 90%, and 66%, respectively (NNM 10). For extrapancreatic lesions, adequacy, accuracy, sensitivity, specificity, and tissue core sampling were 95.3%, 95.3%, 92.6%, 100%, and 84.5% (NNM 21.3). CONCLUSIONS: The 20G PC needle showed high diagnostic adequacy and accuracy, regardless the access route. Wolters Kluwer - Medknow 2019 2019-05-09 /pmc/articles/PMC6714486/ /pubmed/31115386 http://dx.doi.org/10.4103/eus.eus_14_19 Text en Copyright: © 2019 Spring Media Publishing Co. Ltd http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Fabbri, Carlo Fornelli, Adele Fuccio, Lorenzo Giovanelli, Silvia Tarantino, Ilaria Antonini, Filippo Liotta, Rosa Frazzoni, Leonardo Gusella, Paolo La Marca, Marina Barresi, Luca Macarri, Giampiero Traina, Mario De Biase, Dario Fiorino, Siro Jovine, Elio Larghi, Alberto Cennamo, Vincenzo High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title | High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title_full | High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title_fullStr | High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title_full_unstemmed | High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title_short | High diagnostic adequacy and accuracy of the new 20G procore needle for EUS-guided tissue acquisition: Results of a large multicentre retrospective study |
title_sort | high diagnostic adequacy and accuracy of the new 20g procore needle for eus-guided tissue acquisition: results of a large multicentre retrospective study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714486/ https://www.ncbi.nlm.nih.gov/pubmed/31115386 http://dx.doi.org/10.4103/eus.eus_14_19 |
work_keys_str_mv | AT fabbricarlo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT fornelliadele highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT fucciolorenzo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT giovanellisilvia highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT tarantinoilaria highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT antoninifilippo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT liottarosa highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT frazzonileonardo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT gusellapaolo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT lamarcamarina highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT barresiluca highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT macarrigiampiero highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT trainamario highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT debiasedario highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT fiorinosiro highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT jovineelio highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT larghialberto highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy AT cennamovincenzo highdiagnosticadequacyandaccuracyofthenew20gprocoreneedleforeusguidedtissueacquisitionresultsofalargemulticentreretrospectivestudy |