Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic

Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting and patients’ self-testing. We determined the agreement of prothrombin time international normalized ratio (INR) results by POCT coagulometer and laboratory instrument through a comparative analysis and in...

Descripción completa

Detalles Bibliográficos
Autores principales: Moiz, Bushra, Rashid, Anila, Hasan, Muhammad, Jafri, Lena, Raheem, Ahmed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714735/
https://www.ncbi.nlm.nih.gov/pubmed/29374969
http://dx.doi.org/10.1177/1076029617752247
_version_ 1783447111190183936
author Moiz, Bushra
Rashid, Anila
Hasan, Muhammad
Jafri, Lena
Raheem, Ahmed
author_facet Moiz, Bushra
Rashid, Anila
Hasan, Muhammad
Jafri, Lena
Raheem, Ahmed
author_sort Moiz, Bushra
collection PubMed
description Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting and patients’ self-testing. We determined the agreement of prothrombin time international normalized ratio (INR) results by POCT coagulometer and laboratory instrument through a comparative analysis and investigated whether the results of POCT coagulometer can reliably be used without being confirmed by standard laboratory analyzer. A total of 200 INR measurements by POCT coagulometer (CoaguChek XS Pro) and laboratory analyzer (Sysmex CS2000i) were compared using Passing-Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurement was further analyzed in relation to dosing decision. The correlation of INR measurements between CoaguChek XS Pro and Sysmex CS2000i was excellent (correlation coefficient = 0.973). The overall mean difference was 0.21 INR ± 0.32 (range: 1.7-0.44). The mean difference was found to get increased as INR results increased and was 0.09 in the subtherapeutic range (≤1.9 INR), 0.29 INR in the therapeutic range (2.0-3.0 INR), while 0.4 INR in the supratherapeutic range (>3.0 INR). The overall agreement was excellent (κ = 0.916) and overall 11 (5.5%) of 200 INR measurements showed a difference in dosing decision between the 2 instruments. The positive bias of POC-INR is evident in the supratherapeutic range which could affect the dosing decision requiring confirmation with the laboratory INR measurement.
format Online
Article
Text
id pubmed-6714735
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-67147352019-09-04 Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic Moiz, Bushra Rashid, Anila Hasan, Muhammad Jafri, Lena Raheem, Ahmed Clin Appl Thromb Hemost Original Articles Point-of-care testing (POCT) coagulometers are increasingly being used in the hospital setting and patients’ self-testing. We determined the agreement of prothrombin time international normalized ratio (INR) results by POCT coagulometer and laboratory instrument through a comparative analysis and investigated whether the results of POCT coagulometer can reliably be used without being confirmed by standard laboratory analyzer. A total of 200 INR measurements by POCT coagulometer (CoaguChek XS Pro) and laboratory analyzer (Sysmex CS2000i) were compared using Passing-Bablok regression analysis and Bland-Altman plot. Agreement of the INR measurement was further analyzed in relation to dosing decision. The correlation of INR measurements between CoaguChek XS Pro and Sysmex CS2000i was excellent (correlation coefficient = 0.973). The overall mean difference was 0.21 INR ± 0.32 (range: 1.7-0.44). The mean difference was found to get increased as INR results increased and was 0.09 in the subtherapeutic range (≤1.9 INR), 0.29 INR in the therapeutic range (2.0-3.0 INR), while 0.4 INR in the supratherapeutic range (>3.0 INR). The overall agreement was excellent (κ = 0.916) and overall 11 (5.5%) of 200 INR measurements showed a difference in dosing decision between the 2 instruments. The positive bias of POC-INR is evident in the supratherapeutic range which could affect the dosing decision requiring confirmation with the laboratory INR measurement. SAGE Publications 2018-01-28 2018-10 /pmc/articles/PMC6714735/ /pubmed/29374969 http://dx.doi.org/10.1177/1076029617752247 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Moiz, Bushra
Rashid, Anila
Hasan, Muhammad
Jafri, Lena
Raheem, Ahmed
Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title_full Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title_fullStr Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title_full_unstemmed Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title_short Prospective Comparison of Point-of-Care Device and Standard Analyzer for Monitoring of International Normalized Ratio in Outpatient Oral Anticoagulant Clinic
title_sort prospective comparison of point-of-care device and standard analyzer for monitoring of international normalized ratio in outpatient oral anticoagulant clinic
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714735/
https://www.ncbi.nlm.nih.gov/pubmed/29374969
http://dx.doi.org/10.1177/1076029617752247
work_keys_str_mv AT moizbushra prospectivecomparisonofpointofcaredeviceandstandardanalyzerformonitoringofinternationalnormalizedratioinoutpatientoralanticoagulantclinic
AT rashidanila prospectivecomparisonofpointofcaredeviceandstandardanalyzerformonitoringofinternationalnormalizedratioinoutpatientoralanticoagulantclinic
AT hasanmuhammad prospectivecomparisonofpointofcaredeviceandstandardanalyzerformonitoringofinternationalnormalizedratioinoutpatientoralanticoagulantclinic
AT jafrilena prospectivecomparisonofpointofcaredeviceandstandardanalyzerformonitoringofinternationalnormalizedratioinoutpatientoralanticoagulantclinic
AT raheemahmed prospectivecomparisonofpointofcaredeviceandstandardanalyzerformonitoringofinternationalnormalizedratioinoutpatientoralanticoagulantclinic