Cargando…
Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease
Aortic stenosis (AS) and coronary artery disease (CAD) influence the coagulation system, potentially affecting hemostasis during cardiac surgery. Our aim was to evaluate 2 preoperative global hemostasis assays, plasma thrombin potential and thromboelastometry, in patients with severe aortic valve st...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714769/ https://www.ncbi.nlm.nih.gov/pubmed/29768939 http://dx.doi.org/10.1177/1076029618776374 |
_version_ | 1783447118883586048 |
---|---|
author | Dimberg, Axel Alström, Ulrica Ståhle, Elisabeth Christersson, Christina |
author_facet | Dimberg, Axel Alström, Ulrica Ståhle, Elisabeth Christersson, Christina |
author_sort | Dimberg, Axel |
collection | PubMed |
description | Aortic stenosis (AS) and coronary artery disease (CAD) influence the coagulation system, potentially affecting hemostasis during cardiac surgery. Our aim was to evaluate 2 preoperative global hemostasis assays, plasma thrombin potential and thromboelastometry, in patients with severe aortic valve stenosis compared to patients with CAD. A secondary aim was to test whether the assays were associated with postoperative bleeding. Calibrated automated thrombogram (CAT) in platelet-poor plasma and rotational thromboelastometry (ROTEM) in whole blood were analyzed in patients scheduled for elective surgery due to severe AS (n = 103) and stable CAD (n = 68). Patients with AS displayed higher plasma thrombin potential, both thrombin peak with median 252 nmol/L (interquartile range 187-319) and endogenous thrombin potential (ETP) with median 1552 nmol/L/min (interquartile range 1340-1838), when compared to patients with CAD where thrombin peak was median 174 nmol/L (interquartile range 147-229) and ETP median 1247 nmol/L/min (interquartile range 1034-1448; both P < .001). Differences persisted after adjustment for age, gender, comorbidity, and antithrombotic treatment. Differences observed in thromboelastometry between the groups did not persist after adjustment for baseline characteristics. Bleeding amount showed no relationship with plasma thrombin potential but weakly to thromboelastometry (R(2) = .064, P = .001). Patients with AS exhibited preoperatively increased plasma thrombin potential compared to patients with CAD. Plasma thrombin potential was not predictive for postoperative bleeding in patients scheduled for elective surgery. |
format | Online Article Text |
id | pubmed-6714769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-67147692019-09-04 Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease Dimberg, Axel Alström, Ulrica Ståhle, Elisabeth Christersson, Christina Clin Appl Thromb Hemost Original Articles Aortic stenosis (AS) and coronary artery disease (CAD) influence the coagulation system, potentially affecting hemostasis during cardiac surgery. Our aim was to evaluate 2 preoperative global hemostasis assays, plasma thrombin potential and thromboelastometry, in patients with severe aortic valve stenosis compared to patients with CAD. A secondary aim was to test whether the assays were associated with postoperative bleeding. Calibrated automated thrombogram (CAT) in platelet-poor plasma and rotational thromboelastometry (ROTEM) in whole blood were analyzed in patients scheduled for elective surgery due to severe AS (n = 103) and stable CAD (n = 68). Patients with AS displayed higher plasma thrombin potential, both thrombin peak with median 252 nmol/L (interquartile range 187-319) and endogenous thrombin potential (ETP) with median 1552 nmol/L/min (interquartile range 1340-1838), when compared to patients with CAD where thrombin peak was median 174 nmol/L (interquartile range 147-229) and ETP median 1247 nmol/L/min (interquartile range 1034-1448; both P < .001). Differences persisted after adjustment for age, gender, comorbidity, and antithrombotic treatment. Differences observed in thromboelastometry between the groups did not persist after adjustment for baseline characteristics. Bleeding amount showed no relationship with plasma thrombin potential but weakly to thromboelastometry (R(2) = .064, P = .001). Patients with AS exhibited preoperatively increased plasma thrombin potential compared to patients with CAD. Plasma thrombin potential was not predictive for postoperative bleeding in patients scheduled for elective surgery. SAGE Publications 2018-05-16 2018-11 /pmc/articles/PMC6714769/ /pubmed/29768939 http://dx.doi.org/10.1177/1076029618776374 Text en © The Author(s) 2018 http://creativecommons.org/licenses/by-nc/4.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Original Articles Dimberg, Axel Alström, Ulrica Ståhle, Elisabeth Christersson, Christina Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title | Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title_full | Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title_fullStr | Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title_full_unstemmed | Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title_short | Higher Preoperative Plasma Thrombin Potential in Patients Undergoing Surgery for Aortic Stenosis Compared to Surgery for Stable Coronary Artery Disease |
title_sort | higher preoperative plasma thrombin potential in patients undergoing surgery for aortic stenosis compared to surgery for stable coronary artery disease |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6714769/ https://www.ncbi.nlm.nih.gov/pubmed/29768939 http://dx.doi.org/10.1177/1076029618776374 |
work_keys_str_mv | AT dimbergaxel higherpreoperativeplasmathrombinpotentialinpatientsundergoingsurgeryforaorticstenosiscomparedtosurgeryforstablecoronaryarterydisease AT alstromulrica higherpreoperativeplasmathrombinpotentialinpatientsundergoingsurgeryforaorticstenosiscomparedtosurgeryforstablecoronaryarterydisease AT stahleelisabeth higherpreoperativeplasmathrombinpotentialinpatientsundergoingsurgeryforaorticstenosiscomparedtosurgeryforstablecoronaryarterydisease AT christerssonchristina higherpreoperativeplasmathrombinpotentialinpatientsundergoingsurgeryforaorticstenosiscomparedtosurgeryforstablecoronaryarterydisease |